Difference between revisions of "VTube-LASER v1.57"
Line 13: | Line 13: | ||
__NOTOC__ | __NOTOC__ | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Use the BENDER MASTER XYZ to Establish the VTube Master=== | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender. | ||
+ | <br><br> | ||
+ | The toolbar on the right has a new button that allows you to RECALL MASTER XYZ from a bender to create the MASTER data in VTube. | ||
+ | <br><br> | ||
+ | Before the transfer occurs, VTube will ask you to confirm that you mean to overwrite the MASTER data in VTube.<br><br> | ||
+ | If the incoming bender data does not have MASTER XYZ data, then VTube will warn you and stop the transfer. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_1_57_toolbar_filename.jpg|300px]]. | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Bender Setup Menu Redesigned=== | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The Bender Setup user interface menu was redesigned. | ||
+ | <br><br> | ||
+ | * The bender number font size is larger. | ||
+ | * The toolbar on the right is more compact. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_1_57_toolbar_filename.jpg|300px]]. | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Springback Compensation for Correction Adjustments === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The realtime springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone. So - if the adjustment value for a 90 degree bend is found to be +3 degrees, then the springback compensation added to the bend is calculated based on 3 degrees, not 93 degrees. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_1_57_toolbar_filename.jpg|300px]]. | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Transfer Master LRA to Setup LRA Springback Compensation === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | When transferring data from the MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero.</td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_1_57_toolbar_filename.jpg|300px]]. | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
===[[image:Check.jpg|25px]] NEW: Part Name in Toolbar === | ===[[image:Check.jpg|25px]] NEW: Part Name in Toolbar === |
Revision as of 14:08, 12 January 2011
Revision 1.57Back to VTube-LASER |
NEW: Use the BENDER MASTER XYZ to Establish the VTube Master
You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender.
|
ENHANCED: Bender Setup Menu Redesigned
The Bender Setup user interface menu was redesigned.
|
ENHANCED: Springback Compensation for Correction Adjustments
The realtime springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone. So - if the adjustment value for a 90 degree bend is found to be +3 degrees, then the springback compensation added to the bend is calculated based on 3 degrees, not 93 degrees. |
NEW: Transfer Master LRA to Setup LRA Springback Compensation
When transferring data from the MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero. |
NEW: Part Name in Toolbar
The current part name is now displayed in the toolbar below the VTube-LASER logo. |
NEW- Springback Values Transfer from Overbend
VTube-LASER can now receive springback data from Overbend with the press of a single button in the Overbend Calculator. |
NEW: Transfer New Values in Supravision Protocol
New values are included in Supravision file transfers (imports/exports/bender corrections):
|
|
ENHANCED - Other Changes
Other Pages