Difference between revisions of "VTube-LASER v1.67"
Line 22: | Line 22: | ||
<td width=300> | <td width=300> | ||
VTube uses the Split Bend feature as a powerful way to handle large angle bends. The feature is simple to use, and allows you to scan a large sample of data to ensure that the calculates are precise. | VTube uses the Split Bend feature as a powerful way to handle large angle bends. The feature is simple to use, and allows you to scan a large sample of data to ensure that the calculates are precise. | ||
+ | <br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_splitbendsetup_button.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | [[image:vtube-laser_splitbend.jpg|525px]] | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Automatic Combination of Bend Data=== | ||
+ | |||
+ | [[image:vtube-laser_screen_1_67.jpg|500px]] | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | When a split bend is used to create a straight in the middle of a bend, VTube-LASER automatically assumes that the split bends should be re-combined into one bend in all bend data charts. | ||
<br><br> | <br><br> | ||
</td> | </td> | ||
Line 51: | Line 67: | ||
[[image:vtube-laser_disconnectfromarm.jpg|525px]] | [[image:vtube-laser_disconnectfromarm.jpg|525px]] | ||
<br><br> | <br><br> | ||
− | |||
===[[image:Check.jpg|25px]] NEW - Reset Coordinate Datum for MASTER or MEASURED to Zero=== | ===[[image:Check.jpg|25px]] NEW - Reset Coordinate Datum for MASTER or MEASURED to Zero=== |
Revision as of 23:11, 20 July 2011
Revision 1.67Back to VTube-LASER |
Contents |
NEW: Split Bend Feature
VTube uses the Split Bend feature as a powerful way to handle large angle bends. The feature is simple to use, and allows you to scan a large sample of data to ensure that the calculates are precise.
|
NEW: Automatic Combination of Bend Data
When a split bend is used to create a straight in the middle of a bend, VTube-LASER automatically assumes that the split bends should be re-combined into one bend in all bend data charts.
|
NEW: Operator Chooses When to Connect the the FARO
Previous versions of VTube always assumed that operators meant to connect to a FARO arm. This causes the interface to pause repeatedly while it tries to reconnect to the arm that is not present.
|
NEW - Reset Coordinate Datum for MASTER or MEASURED to Zero
|
NEW - Add After Row in MASTER XYZ
|
Other Changes
|
|
|
|
|
Issues with this version fixed in newer versions
|
Other Pages
- Back to VTube-LASER
VTube-LASER Training Video - How to perform effective end scans. |