Difference between revisions of "VTube-STEP v1.77"
(30 intermediate revisions by one user not shown) | |||
Line 24: | Line 24: | ||
New imports and exports were added: | New imports and exports were added: | ||
− | * Example of a new | + | * Example of a new IMPORT: Solid Edge XpresRoute bender files in the TXT format<br><br> |
− | * | + | * Example of a new EXPORT: [[SMI]] bender format |
<br><br><br> | <br><br><br> | ||
− | (Note about the XpresRoute import: This file format uses bender LRA data to define the tube shape, therefore the original orientation of the part is lost during export from Solid Edge. Also this file does not contain the tube diameter.) | + | (Note about the XpresRoute import: This file format uses bender LRA data to define the tube shape, therefore the original orientation of the part is lost during export from Solid Edge. Also this file does not contain the tube diameter. However, it does bring in the part name, the linear display unit, the cut length, and the LRA bender data.) |
+ | <br><br> | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
[[image:vtube-step_v1.77_import_export.jpg|300px]] | [[image:vtube-step_v1.77_import_export.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: New End Length Adjustment Fields=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | These new fields allow you to dynamically adjust the end lengths during calculation of the bender data LENGTH columns.<br><br> | ||
+ | These values act like the TubeCalc material end length fields - and allows that data to be imported. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-step_end_length_adjustment_fields.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Changed End Trim Offset Field Names=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The original End Trim Offset field names were changed by default to "Solid Model Offset" to reflect how these values are used in VTube.<br><br> | ||
+ | These values adjust the end point location relative to the solid model when the centerline is calculated from the solid model. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-step_end_solid_model_offsets.jpg|300px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 48: | Line 76: | ||
</table> | </table> | ||
+ | ===[[image:Check.jpg|25px]] REPAIR: TubeCalc Project File Linear Units Import Properly=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | Linear units are now always properly imported into VTube from TubeCalc files.<br><br> | ||
+ | Previous versions would sometimes improperly interpret the Inch or Millimeter setting in the TubeCalc file. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | ===[[image:Check.jpg|25px]] ENHANCED: The Linear Units Switches to the Import File Units=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | VTube now always switches to the linear units used in the imported TubeCalc, Solid Edge, or Supravision file.<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: TubeCalc Project Imports Include More Values=== | ||
+ | The following values were added to TubeCalc imports in this version:<br><br> | ||
+ | <table cellpadding=5> | ||
+ | <tr> | ||
+ | <td><b>From TubeCalc</b></td><td></td><td><b>To VTube</b></td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td>Customer Name</td><td>[[image:small_right_green_arrow.png]]</td><td>Customer</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Material Name</td><td>[[image:small_right_green_arrow.png]]</td><td>Material Spec</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>User</td><td>[[image:small_right_green_arrow.png]]</td><td>Author</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Material Offset 1</td><td>[[image:small_right_green_arrow.png]]</td><td>A-End Length Adjust</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Material Offset 2</td><td>[[image:small_right_green_arrow.png]]</td><td>B-End Length Adjust</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Measuring Center Offset A</td><td>[[image:small_right_green_arrow.png]]</td><td>A-End Measured Offset</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Measuring Center Offset B</td><td>[[image:small_right_green_arrow.png]]</td><td>B-End Measured Offset</td> | ||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] FIXED: Projection Tolerances Now Change Units Properly === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The projection tolerance now handles a change in linear units properly.<br><br> | ||
+ | Projection tolerances allow VTube to know how precise it must be to qualify a projection intersection as successful. Some models have less precise surfaces - so the tolerance needs to be increased for a successful calculation of centerline.<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube_v1.77_projectiontoleranceedit.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
==Other Pages== | ==Other Pages== | ||
*Back to the [[VTube]] page | *Back to the [[VTube]] page |
Latest revision as of 01:19, 3 August 2012
Revision 1.77
|
NEW: Adjustable Import/Export Interface with New Choices
The Import/Export interface is now expandable/compressible.
(Note about the XpresRoute import: This file format uses bender LRA data to define the tube shape, therefore the original orientation of the part is lost during export from Solid Edge. Also this file does not contain the tube diameter. However, it does bring in the part name, the linear display unit, the cut length, and the LRA bender data.)
|
NEW: New End Length Adjustment Fields
These new fields allow you to dynamically adjust the end lengths during calculation of the bender data LENGTH columns. |
ENHANCED: Changed End Trim Offset Field Names
The original End Trim Offset field names were changed by default to "Solid Model Offset" to reflect how these values are used in VTube. |
NEW: Reset Origin to Zero in XYZ Data
Now you can reset the origin in the XYZ data to ZERO in VTube-STEP. |
REPAIR: TubeCalc Project File Linear Units Import Properly
Linear units are now always properly imported into VTube from TubeCalc files. |
ENHANCED: The Linear Units Switches to the Import File Units
VTube now always switches to the linear units used in the imported TubeCalc, Solid Edge, or Supravision file. |
ENHANCED: TubeCalc Project Imports Include More Values
The following values were added to TubeCalc imports in this version:
FIXED: Projection Tolerances Now Change Units Properly
The projection tolerance now handles a change in linear units properly. |
Other Pages
- Back to the VTube page