Difference between revisions of "VTube-STEP v1.77"
(4 intermediate revisions by one user not shown) | |||
Line 76: | Line 76: | ||
</table> | </table> | ||
− | ===[[image:Check.jpg|25px]] REPAIR: | + | ===[[image:Check.jpg|25px]] REPAIR: TubeCalc Project File Linear Units Import Properly=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
Line 103: | Line 103: | ||
The following values were added to TubeCalc imports in this version:<br><br> | The following values were added to TubeCalc imports in this version:<br><br> | ||
<table cellpadding=5> | <table cellpadding=5> | ||
+ | <tr> | ||
+ | <td><b>From TubeCalc</b></td><td></td><td><b>To VTube</b></td> | ||
+ | </tr> | ||
+ | |||
<tr> | <tr> | ||
<td>Customer Name</td><td>[[image:small_right_green_arrow.png]]</td><td>Customer</td> | <td>Customer Name</td><td>[[image:small_right_green_arrow.png]]</td><td>Customer</td> | ||
Line 125: | Line 129: | ||
</tr> | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] FIXED: Projection Tolerances Now Change Units Properly === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The projection tolerance now handles a change in linear units properly.<br><br> | ||
+ | Projection tolerances allow VTube to know how precise it must be to qualify a projection intersection as successful. Some models have less precise surfaces - so the tolerance needs to be increased for a successful calculation of centerline.<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube_v1.77_projectiontoleranceedit.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
</table> | </table> | ||
Latest revision as of 01:19, 3 August 2012
Revision 1.77
|
NEW: Adjustable Import/Export Interface with New Choices
The Import/Export interface is now expandable/compressible.
(Note about the XpresRoute import: This file format uses bender LRA data to define the tube shape, therefore the original orientation of the part is lost during export from Solid Edge. Also this file does not contain the tube diameter. However, it does bring in the part name, the linear display unit, the cut length, and the LRA bender data.)
|
NEW: New End Length Adjustment Fields
These new fields allow you to dynamically adjust the end lengths during calculation of the bender data LENGTH columns. |
ENHANCED: Changed End Trim Offset Field Names
The original End Trim Offset field names were changed by default to "Solid Model Offset" to reflect how these values are used in VTube. |
NEW: Reset Origin to Zero in XYZ Data
Now you can reset the origin in the XYZ data to ZERO in VTube-STEP. |
REPAIR: TubeCalc Project File Linear Units Import Properly
Linear units are now always properly imported into VTube from TubeCalc files. |
ENHANCED: The Linear Units Switches to the Import File Units
VTube now always switches to the linear units used in the imported TubeCalc, Solid Edge, or Supravision file. |
ENHANCED: TubeCalc Project Imports Include More Values
The following values were added to TubeCalc imports in this version:
FIXED: Projection Tolerances Now Change Units Properly
The projection tolerance now handles a change in linear units properly. |
Other Pages
- Back to the VTube page