Difference between revisions of "Revision: Benderlink for Chiyoda/Keins 6.7"
(→25px ENHANCED - New Serial Port COM Engine Available) |
(→25px ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter) |
||
(7 intermediate revisions by one user not shown) | |||
Line 19: | Line 19: | ||
<table> | <table> | ||
− | <tr> | + | <tr valign=top> |
<td width=400> | <td width=400> | ||
Line 45: | Line 45: | ||
<table> | <table> | ||
− | <tr> | + | <tr valign=top> |
<td width=400> | <td width=400> | ||
Line 52: | Line 52: | ||
If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula: | If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula: | ||
<br><br> | <br><br> | ||
− | (Rad Level 1) / 1.5<br><br> | + | <b>(Rad Level 1) / 1.5</b><br><br> |
If the Rad Level 1 value is zero, then Benderlink will use this formula:<br><br> | If the Rad Level 1 value is zero, then Benderlink will use this formula:<br><br> | ||
− | (Rad Level 2) / 1.5<br><br> | + | <b>(Rad Level 2) / 1.5</b><br><br> |
− | If both radius level values are zero, then Benderlink will set the diameter to 1 unit.<br><br>A non-zero diameter is important for communicating with ROMER [[DOCS]] software because DOCS will report a corrupted file if it senses a zero | + | |
+ | * If both radius level values are zero, then Benderlink will set the diameter to 1 unit.<br><br>A non-zero diameter is important for communicating with ROMER [[DOCS]] software because DOCS will report a corrupted file if it senses a zero diameter. (Some measuring center software packages, like [[VTube-LASER]] will continue with a zero diameter.)<br><br> | ||
+ | * If the radius stop is enabled, and Benderlink stops for input while the measuring center is performing a recall, then the recall process will time out if the new diameter is not entered within the time out period. | ||
</td> | </td> |
Latest revision as of 13:21, 15 November 2013
Revision 6.7Back to Benderlink for Chiyoda |
ENHANCED - New Serial Port COM Engine Available
This Benderlink can use either the new WinSoft COM engine for faster communications, or the older MarshallSoft COM engine for cases where the older engine works better. [Communications Setup] COM Engine=WinSoft or [Communications Setup] COM Engine=Marshallsoft
|
ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter
Benderlink can now stop the process and ask for input if a zero diameter is encountered. If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula:
|
OTHER PAGES
- Back to Benderlink for KEINS
- Back to Benderlink for Chiyoda
- Benderlink for Chiyoda FAQ
- About Chiyoda - See this page for control version information.