Difference between revisions of "VTube-LASER v1.85.1"
(→25px ENHANCED: Added + and - tolerances for end lengths) |
(→25px ENHANCED: Added PLUS and MINUS tolerances for End Lengths) |
||
(12 intermediate revisions by one user not shown) | |||
Line 5: | Line 5: | ||
==Revision 1.85.1== | ==Revision 1.85.1== | ||
* Back to [[VTube-STEP]] | * Back to [[VTube-STEP]] | ||
+ | * Back to [[VTube-STEP Revisions]] | ||
* Back to [[VTube Software Updates]] (for LASER Mode) | * Back to [[VTube Software Updates]] (for LASER Mode) | ||
* Back to [[VTube-LASER]] | * Back to [[VTube-LASER]] | ||
+ | |||
</td> | </td> | ||
Line 18: | Line 20: | ||
* See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version. | * See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version. | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Added PLUS and MINUS tolerances for End Lengths=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | |||
+ | [[image:vtube-laser-1.85.1_endlength_posneg_tolerances_gridcloseup.png|400px]]<br><br> | ||
+ | |||
+ | |||
+ | Some qualification specs have unique tolerances for positive and negative lengths, so we added + and - tolerances for the end lengths.<br><br> | ||
+ | |||
+ | * The End Length grid in the Inspection menu has minus as well as plus tolerances in the grid. | ||
+ | * The tolerance envelopes in the graphics viewport shows both the positive and negative tolerances with transparent cylinders that run in both directions. | ||
+ | * The Inspection report template includes the + and - values in the End Length reporting. | ||
+ | <br><br> | ||
+ | [[image:vtube-1.85.1_endlength_plusminustolerance_envelopes.png|400px]] | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | |||
+ | [[image:vtube-1.85.1_endlength_plusminustolerance.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: SolidWorks Builder - End Offsets Added=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | The SolidWorks tube builder can now:<br> | ||
+ | * Build extruded diameter offsets at the ends of the tube.<br><br> | ||
+ | [[image:vtube-step-1.84.1_buildsolidworks_negativeoffset.png|400px]]<br> | ||
+ | |||
+ | <br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-step-1.84.1_PreSolidWorksPart.png|400px]]<br><br> | ||
+ | [[image:vtube-step-1.84.1_buildsolidworks_positiveoffset.png|400px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
<br><br> | <br><br> | ||
Line 84: | Line 129: | ||
− | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] NEW: Export Dialog Windows With Configurable Paths=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | + | * New Export dialog windows are now present for every type of file export with new features.<br><br> | |
− | + | * Persistent Export Paths: Every type of export now has its own unique output path setting that is remembered in the VTube persistent local configuration file. This allows you to set a unique path for your common exports. As long as the path continues to exist, VTube will never forget to use that path as default for export for that file type.<br><br> | |
− | * | + | *Display Data in Notepad++: VTube can automatically display the file created in Notepad++ after it is exported.<br><br> |
− | * | + | *Template File Edit: For export styles that require a template file for merging exported data to, VTube allows operators to edit the file before exporting.<br><br> |
− | * | + | [[image:vtube-step_1.85_exportwindow_transfluid.png|400px]] |
− | + | <br> | |
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | + | [[image:vtube-step_1.85_exportwindows.png|400px]]<br><br> | |
− | [[image:vtube- | + | [[image:vtube-step_1.85_exportfile_notepaddisplay.png|400px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | <br><br> | ||
− | |||
===[[image:Check.jpg|25px]] Other Changes=== | ===[[image:Check.jpg|25px]] Other Changes=== | ||
Line 108: | Line 153: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | * Timer inefficiencies that could bog down systems were optimized. The result is that VTube now runs faster than before. | + | * Timer inefficiencies that could bog down systems were optimized. The result is that VTube now runs faster than before.<br><br> |
+ | * Several of the support packages that install with VTube are updated: FARO driver (for new ES scanner), Notepad++, Cute PDF driver, GhostScript, HASP hardware key driver, and the Keycheck utility. | ||
Latest revision as of 02:56, 7 January 2014
Revision 1.85.1
|
- See VTube-LASER Customer Support Page to download the latest version.
ENHANCED: Added PLUS and MINUS tolerances for End Lengths
|
ENHANCED: SolidWorks Builder - End Offsets Added
The SolidWorks tube builder can now:
|
FIXED: Memory Leaks
A few heavy-use customers were reporting that the Alignment feature, if used for hours repeatedly, would eventually cause a lock to the software. We discovered that VTube would eventually run out of Windows memory if used for extended periods of time because several additional megabytes of memory was used but never released during each alignment.
This fix can be proved by running the Task Manager Performance menu, and viewing the "Available" memory value during an alignment. |
ENHANCED: Repaired and Improved Benderlink Setup Menu
We discovered issues with the Benderlink Setup menu, where edited data was not always stored after it was changed in the grid. This has been repaired. All data entered is saved.
|
ENHANCED: Improved System Options Menu
The System Options menu is changed:
|
NEW: Export Dialog Windows With Configurable Paths
|
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor