Difference between revisions of "VTube-LASER v1.92"

From ATTWiki
Jump to: navigation, search
(Created page with "<table> <tr cellpadding=10> <td width=225> 300px ==Revision 1.92== * Back to VTube-STEP * Back to VTube-STEP Revisions * Back to VTube...")
 
Line 23: Line 23:
  
  
 +
===[[image:Check.jpg|25px]] NEW: Export to Laservision Spreadsheet Format Files (in VTube-STEP mode) ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=400>
 +
The Eaton Leonard Laservision measuring center can import CSV (Comma Separated Value) files built in an Excel spreadsheet.  This version of VTube (STEP mode) can now export to this format.<br><br>
 +
[[image:vtube-step-1.92_export_laservision.png|400px]]<br><br>
 +
* Include qualification tolerance in the export.<br><br>
 +
* Automatically show CSV file in a text editor for inspection.<br><br>
 +
* Automatically load data into Excel if Excel is available on your system.<br><br>
 +
[[image:vtube-step-1.92_export_direct_excel.png|400px]]<br><br>
 +
</td>
 +
<td width=500>
 +
[[image:laservision_measuring_center.png|300px]]<br><br>
 +
[[image:laservision_import_el_csv.png|400px]]<br><br>
 +
</td>
 +
</tr>
 +
</table>
  
  

Revision as of 20:57, 13 July 2014

Vtube-laser logo.jpg

Revision 1.92


Vtube-laser 1.89 mainscreen.png





Check.jpg NEW: Export to Laservision Spreadsheet Format Files (in VTube-STEP mode)

The Eaton Leonard Laservision measuring center can import CSV (Comma Separated Value) files built in an Excel spreadsheet. This version of VTube (STEP mode) can now export to this format.

Vtube-step-1.92 export laservision.png

  • Include qualification tolerance in the export.

  • Automatically show CSV file in a text editor for inspection.

  • Automatically load data into Excel if Excel is available on your system.

Vtube-step-1.92 export direct excel.png

Laservision measuring center.png

Laservision import el csv.png


Check.jpg Other Changes

  • IMPORTANT Fix to bug in END TRIM/EXTEND distances in the inspection reports. Sometimes the direction would be inverted. This has been resolved.

  • Now you can click on the scanner control labels to load the FARO Scanner control window.

  • VTube will automatically set the wall thickness to 0.001 inches or 0.025 millimeters when the value is set to zero during VTube-STEP solid model centerline calculations.

  • Now you can press the Enter key to close the information dialog.

  • The FARO calibration dialogs now show either Inches or Millimeters

  • Comments display in a dialog during project load

  • The Scanner Control settings are stored in VTube project files. In order for the scanner setup to be transferred into the arm, it is necessary to pull the arm from the cradle before the setup is transferred. VTube will ask you to move the arm when it is important.

  • The USB FARO driver icon is now displayed in the toolbar at the bottom of Windows.

  • The "Clear text" button in the editor box works again.

  • VTube now warns if you attempt to align tube shapes using the 321 PLP mode without having performed a 321 PLP setup.

  • Previous versions of VTube culled out many points for display. This version of VTube now draws all laser points measured on the screen. This gives the operator a better idea of the laser coverage during measurement - which is a significant indicator of measure quality.

Vtube-laser-1.91 click label load scanner control.png

Vtube-laser-1.91-321plp imcomplete setup.png

Other