Difference between revisions of "DCP - Diameter Cut Planes"
(→Maximum Cloud Width Matters in DCP) |
|||
(44 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
+ | [[image:DCP Logo Graphic with Exhaust Header.png|500px]]<br><br> | ||
+ | |||
+ | |||
+ | VTube-LASER Diameter Cut Planes or the "DCP" feature in VTube-LASER, solves a scanning issue where multiple objects are in the view of the laser scanner at one time - but you must scan only one straight. | ||
+ | |||
+ | In previous versions, the only solution was to switch to using the ball probe in those sections where many objects were close to the tube straight being measured. | ||
+ | <br> | ||
+ | |||
+ | An example of how DCP is used is for header assemblies like this one at Holley MSD. The only way to laser scan this header assembly is to use the DCP feature.<br> | ||
+ | |||
+ | [[image:holleymsd_measureheaderassembly2.png|500px]] | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | =Version Information= | ||
* VTube-LASER Version: 2.6 | * VTube-LASER Version: 2.6 | ||
− | *Date Released: July | + | *Date Released: July 25, 2016 |
+ | <br><br> | ||
+ | |||
+ | =Related Pages= | ||
+ | * Back to [[VTube-LASER]] | ||
+ | * Back to [[VTube-LASER v2.6]] | ||
+ | * See Related Subject: [[How to Measure Tubes Attached to an Evaporator]] | ||
+ | |||
<br><br> | <br><br> | ||
− | |||
− | + | =Videos Showing DCP= | |
+ | ====Video 60: Diameter Cut Plane - Quick Tutorial ==== | ||
+ | <table width=600> | ||
+ | <tr> | ||
+ | <td width=200> | ||
+ | Michael Cone explains the concept behind the DCP (Diameter Cut Plane) feature and demonstrates how it works. This is a new innovation added in version 2.6. | ||
+ | </td> | ||
+ | <td width=200> | ||
+ | [[image:DCPtutorialVideo.png|200px]]<br> | ||
+ | </td> | ||
+ | <td width=200> | ||
+ | * View [https://youtu.be/NR56NeQSbQI YouTube] | ||
+ | * View [http://www.advancedtubular.com/vtube-laser/vtube-laser_v2.6_dcp_tutorial_demo.mp4 MP4] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ====Video 59: Diameter Cut Plane - Quick Demo ==== | ||
+ | <table width=600> | ||
+ | <tr> | ||
+ | <td width=200> | ||
+ | This video shows what you can do with the DCP (Diameter Cut Plane) feature added in version 2.6. With DCP, even if the laser stripe is crosses multiple straights at the same time, it finds and keeps the closest one - on-the-fly. It even filters out non-diameter objects that are behind the top diameter. | ||
+ | </td> | ||
+ | <td width=200> | ||
+ | [[image:vtube-laser_v2.6_cutplane_video.png|200px]]<br> | ||
+ | </td> | ||
+ | <td width=200> | ||
+ | * View [https://youtu.be/sAcJ7sETzlc YouTube] | ||
+ | * View [http://www.advancedtubular.com/vtube-laser/vtube_laser_2.6_dcp_demo.mp4 MP4] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | __NOTOC__ | ||
=Overview of DCP= | =Overview of DCP= | ||
− | + | ===Measure Across Several Diameters - VTube will find the correct straight=== | |
However, this new feature lets you scan across several diameters or objects of any kind - and still AUTOMATICALLY scan in the single diameter you intend to measure. <br><br> | However, this new feature lets you scan across several diameters or objects of any kind - and still AUTOMATICALLY scan in the single diameter you intend to measure. <br><br> | ||
Line 17: | Line 74: | ||
[[image:vtube-laser_v2.6_diameter_cut_plane_grapic_002.png|500px]]<br><br> | [[image:vtube-laser_v2.6_diameter_cut_plane_grapic_002.png|500px]]<br><br> | ||
− | + | ===Wirebending Applications=== | |
The feature was developed to solve a need when measuring wire bent parts. The orange part shown below is a sample test piece that is formed from 0.2 inch diameter wire. This is a small part that can sit on a tablet (see the black tablet for scale). When measuring this part the FARO scanner stripe often crosses four straights at the same time.<br><br>[[image:vtube-laser_v2.6_orange_cardholder_wirebend.png|500px]]<br><br> | The feature was developed to solve a need when measuring wire bent parts. The orange part shown below is a sample test piece that is formed from 0.2 inch diameter wire. This is a small part that can sit on a tablet (see the black tablet for scale). When measuring this part the FARO scanner stripe often crosses four straights at the same time.<br><br>[[image:vtube-laser_v2.6_orange_cardholder_wirebend.png|500px]]<br><br> | ||
− | + | ====Illustration of the Issue for Small Parts==== | |
Imagine the HD (blue) laser stripe measuring one of these four straights. In order to measure one, it is very hard to orient the beam in a way that scans only one straight. See this image to show the easiest way to measure straights 1, 3, 9 and 12:<br> | Imagine the HD (blue) laser stripe measuring one of these four straights. In order to measure one, it is very hard to orient the beam in a way that scans only one straight. See this image to show the easiest way to measure straights 1, 3, 9 and 12:<br> | ||
[[image:vtube-laser_v2.6_orange_cardholder_wirebend_pointers_to_4diameter.png|500px]]<br><br> | [[image:vtube-laser_v2.6_orange_cardholder_wirebend_pointers_to_4diameter.png|500px]]<br><br> | ||
In previous versions of VTube-LASER, this was not possible because the data from the four straights would have averaged into one large diameter, or, more likely, VTube would return an error during centerline calculation.<br><br> | In previous versions of VTube-LASER, this was not possible because the data from the four straights would have averaged into one large diameter, or, more likely, VTube would return an error during centerline calculation.<br><br> | ||
'''However, the DCP feature solves this issue by givng the operator a way to cross all four straights by following some simple rules that allow VTube to sort out and select the one straight that you intend to measure.''' | '''However, the DCP feature solves this issue by givng the operator a way to cross all four straights by following some simple rules that allow VTube to sort out and select the one straight that you intend to measure.''' | ||
+ | <br><br> | ||
+ | |||
+ | ===DCP is Not Used in End Scans=== | ||
+ | Even if DCP is enabled, it is never applied to END SCANS since end scans are not actual DIAMETER measurements. End scans only respond to regular cut planes.<br><br> | ||
<br><br> | <br><br> | ||
=Tutorial on How DCP Works= | =Tutorial on How DCP Works= | ||
+ | |||
+ | [[image:VTubeDCPLogo.png|500px]]<br><br> | ||
+ | |||
These two slides illustrate how the DCP feature works:<br><br> | These two slides illustrate how the DCP feature works:<br><br> | ||
Line 51: | Line 115: | ||
<br><br> | <br><br> | ||
+ | |||
+ | =DCP Setup Warning Windows= | ||
+ | VTube has warning windows that help you know when the DCP feature is setup in a way that will cause VTube-LASER to return no scanned points.<br><br> | ||
+ | # If you activate the DCP feature and the maximum cloud radius value goes to ZERO, then these warnings will appear.<br><br> | ||
+ | # If you load a project with the DCP feature setup with the maximum cloud radius value at ZERO, then one of these warnings will appear.<br><br> | ||
+ | |||
+ | [[image:vtube-laser_v2.6_warning_cloudradius_zero.png|700px]] | ||
+ | [[image:vtube-laser_v2.6_warning_cloudradius_zero2.png|700px]]<br><br><br> | ||
+ | |||
=Other= | =Other= | ||
− | *Back to [[VTube-LASER]] | + | * Back to [[VTube-LASER]] |
+ | * See Related Subject: [[How to Measure Tubes Attached to an Evaporator]] |
Latest revision as of 14:00, 20 October 2016
VTube-LASER Diameter Cut Planes or the "DCP" feature in VTube-LASER, solves a scanning issue where multiple objects are in the view of the laser scanner at one time - but you must scan only one straight.
In previous versions, the only solution was to switch to using the ball probe in those sections where many objects were close to the tube straight being measured.
An example of how DCP is used is for header assemblies like this one at Holley MSD. The only way to laser scan this header assembly is to use the DCP feature.
Version Information
- VTube-LASER Version: 2.6
- Date Released: July 25, 2016
Related Pages
- Back to VTube-LASER
- Back to VTube-LASER v2.6
- See Related Subject: How to Measure Tubes Attached to an Evaporator
Videos Showing DCP
Video 60: Diameter Cut Plane - Quick Tutorial
Michael Cone explains the concept behind the DCP (Diameter Cut Plane) feature and demonstrates how it works. This is a new innovation added in version 2.6. |
Video 59: Diameter Cut Plane - Quick Demo
This video shows what you can do with the DCP (Diameter Cut Plane) feature added in version 2.6. With DCP, even if the laser stripe is crosses multiple straights at the same time, it finds and keeps the closest one - on-the-fly. It even filters out non-diameter objects that are behind the top diameter. |
Overview of DCP
Measure Across Several Diameters - VTube will find the correct straight
However, this new feature lets you scan across several diameters or objects of any kind - and still AUTOMATICALLY scan in the single diameter you intend to measure.
The effect on the operator is to reduce stress and increase measuring speed drastically. See this image to understand the basic idea of the DCP feature and how it sorts detects the single diameter you intend to measure:
Wirebending Applications
The feature was developed to solve a need when measuring wire bent parts. The orange part shown below is a sample test piece that is formed from 0.2 inch diameter wire. This is a small part that can sit on a tablet (see the black tablet for scale). When measuring this part the FARO scanner stripe often crosses four straights at the same time.
Illustration of the Issue for Small Parts
Imagine the HD (blue) laser stripe measuring one of these four straights. In order to measure one, it is very hard to orient the beam in a way that scans only one straight. See this image to show the easiest way to measure straights 1, 3, 9 and 12:
In previous versions of VTube-LASER, this was not possible because the data from the four straights would have averaged into one large diameter, or, more likely, VTube would return an error during centerline calculation.
However, the DCP feature solves this issue by givng the operator a way to cross all four straights by following some simple rules that allow VTube to sort out and select the one straight that you intend to measure.
DCP is Not Used in End Scans
Even if DCP is enabled, it is never applied to END SCANS since end scans are not actual DIAMETER measurements. End scans only respond to regular cut planes.
Tutorial on How DCP Works
These two slides illustrate how the DCP feature works:
Scanner Orientation Matters in DCP
The key is to remember that the scanner orientation determines which straight the DCP encounters first.
See this idea illustrated in the serpentine part. The orange arrow is the orientation of the scanner.
- DCP Selection Rule 1: The scanned points are selected based on the orientation of the Diameter Cut Plane relative to the straight.
Maximum Cloud Width Matters in DCP
The yellow ellipsis represents the Maximum Cloud Radius.
The second key is to remember is:
- DCP Selection Rule 2: The scanned points are selected based on the Maximum Cloud Radius value.
DCP Setup Warning Windows
VTube has warning windows that help you know when the DCP feature is setup in a way that will cause VTube-LASER to return no scanned points.
- If you activate the DCP feature and the maximum cloud radius value goes to ZERO, then these warnings will appear.
- If you load a project with the DCP feature setup with the maximum cloud radius value at ZERO, then one of these warnings will appear.
Other
- Back to VTube-LASER
- See Related Subject: How to Measure Tubes Attached to an Evaporator