==About this Page== | ==About this Page== | ||
<table width=1000> | <table width=1000> | ||
<tr valign=top> | <tr valign=top> | ||
− | <td width= | + | <td width=500> |
This page describes the setup and use of the VTube to AMOB communications.<br><br> | This page describes the setup and use of the VTube to AMOB communications.<br><br> | ||
+ | [[image:vtube_v2.5_image to amob.png|600px]] | ||
</td> | </td> | ||
<td width=500> | <td width=500> | ||
− | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 13: | Line 17: | ||
__NOTOC__ | __NOTOC__ | ||
− | == | + | ==The Basics of How It Works== |
<table width=1000> | <table width=1000> | ||
<tr valign=top> | <tr valign=top> | ||
− | |||
− | |||
− | |||
− | |||
<td width=500> | <td width=500> | ||
− | < | + | * VTube sends data to the AMOB by exporting a ".VTL" file that the AMOB can read. Communications can be setup through a standard Windows network connection, or you can use a thumb drive.<br><br> |
− | < | + | |
− | < | + | * The communication is unidirectional toward the bender. It is not possible to RECALL data from the AMOB using this file. The AMOB control only reads this file data.<br><br> |
− | + | * The data that is included in the VTL file that the AMOB can read is the '''BENDER data (X axis, Y Axis, C Axis)'''. The data also includes the '''diameter''', '''wall thickness''', and '''cut length'''.<br><br> | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
− | <td width= | + | <td width=500> |
− | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ==Communications Setup at the | + | ==Communications Setup at the AMOB Bender== |
<table> | <table> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | + | * Connect the AMOB bender to the network using a standard Ethernet cable.<br><br> | |
− | * Connect the | + | * Setup a shared network location either in the AMOB windows control or in a network path on your network.<br><br> |
− | * Setup a shared network location either in the | + | * If you share a folder on the AMOB control, then create a user with a username and password that can be used to login to the computer from the VTube-LASER computer.<br><br> |
− | * | + | |
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image: | + | [[image:amob_program_machine_configuration_press_FARO.png|500px]]<br><br> |
− | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 76: | Line 64: | ||
</table> | </table> | ||
− | ===Setup the Benderlink Network Grid for the | + | ===Setup the Benderlink Network Grid for the AMOB Bender=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | #Choose an unused row in the grid for a new | + | #Choose an unused row in the grid for a new AMOB bender setup. (Click on the image at the right to see a zoomed image.)<br><br> |
#Assign a bender name that will help operators identify what this bender is. This text will be displayed at the top of the Bender Setup menu.<br><br> | #Assign a bender name that will help operators identify what this bender is. This text will be displayed at the top of the Bender Setup menu.<br><br> | ||
− | # | + | #Set the protocol to AMOB VTL Data.<br><br> |
− | #Enter the path to the shared drive or folder in the NetPath field. Use the same location as the | + | #Enter the path to the shared drive or folder in the NetPath field. Use the same location as the AMOB setup. VTube accepts UNC names as well as regular paths with drive letters.<br><br> |
#Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)<br><br> | #Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)<br><br> | ||
#Press Close to save the settings. VTube will save these values to a persistent configuration file that will not change unless you change them in this grid. | #Press Close to save the settings. VTube will save these values to a persistent configuration file that will not change unless you change them in this grid. | ||
Line 89: | Line 77: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:VTube Benderlink Setup for | + | [[image:VTube Benderlink Setup for AMOB VTL.png|600px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 95: | Line 83: | ||
</table> | </table> | ||
− | ==How to SEND MASTER | + | ==How to SEND MASTER BENDER Data to the AMOB Control from VTube-STEP== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | You can import data into VTube-STEP then send the | + | You can import data into VTube-STEP then send the bender data calculated to the AMOB bender using the VTube Input/Export menu.<br> |
− | + | ||
− | + | ||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | |||
</td> | </td> | ||
</tr> | </tr> | ||
Line 115: | Line 100: | ||
<td width=300> | <td width=300> | ||
− | ===At the VTube-STEP | + | ===At the VTube-STEP Main Screen=== |
− | Move to the VTube-STEP computer and follow these steps to transfer the | + | Move to the VTube-STEP computer and follow these steps to transfer the bender data to the AMOB. |
− | # Press the | + | # Press the Import/Export button in the navigation pane. |
− | # | + | # Find and press the AMOB VTL Data button in the Export section. |
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | [[image: | + | [[image:vtube-step_v2.7_AMOB_Export_Button.png|600px]] |
</td> | </td> | ||
Line 131: | Line 113: | ||
</table> | </table> | ||
− | |||
− | |||
− | |||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | ===At the AMOB Bender Data Export Window (inside VTube-STEP)=== | |
− | + | Press the Export button to save a VTL file on the network at the shared path for the AMOB bender. | |
− | === | + | |
− | + | ||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | [[image: | + | [[image:vtube-step_v2.7_AMOB_Export_Window.png|600px]] |
+ | |||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
− | |||
− | |||
− | + | <br><br> | |
− | + | ||
− | + | ==How to SEND CORRECTION Data to the AMOB Control from VTube-LASER== | |
− | + | ||
− | + | ===After Bending the Tube=== | |
− | + | Bend a tube then measure it with VTube-LASER.<br><br> | |
− | + | ||
− | + | ||
− | + | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | |||
− | + | ===Measure the tube with VTube-LASER=== | |
− | + | Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape. | |
− | + | ||
− | + | ||
− | + | ||
<br><br> | <br><br> | ||
− | + | In the VTube-LASER screen shot, you see the actual result of the first tube not qualifying in shape. The red cells in the tangent point grid on the lower left show that the measured tube centerline is out-of-tolerance. | |
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | [[image:vtube-laser_v2. | + | [[image:vtube-laser_v2.7_soco_part_measure.png|600px]]<br><br> |
+ | [[image:vtube-laser_v2.7_soco_out_of_tolerance.png|600px]]<br><br> | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 184: | Line 152: | ||
− | |||
− | |||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | === | + | ===Correct the AMOB with VTube-LASER - Enter BENDER SETUP=== |
− | + | Follow these steps in the VTube-LASER: | |
+ | |||
+ | Press the "BENDER SETUP button in the Navigation Pane. | ||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | [[image: | + | [[image:vtube-laser_2.7_bendersetup_button_navigationpane.png|400px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 204: | Line 172: | ||
<td width=300> | <td width=300> | ||
− | === | + | ===INITIAL Setup of Bender Setup Window=== |
− | + | The first time in this window for a new part will require these steps before you can correct the AMOB bender.<br><br> | |
+ | |||
+ | STEP 1 - Set the correct bender number at the top of the window. The AMOB bender should display if you have already setup the bender protocol in the Benderlink grid. | ||
+ | |||
+ | |||
+ | STEP 2 - Click on the "Setup This Window" button. | ||
+ | |||
+ | |||
+ | STEP 3 - Click on the "Copy Master LRA to Setup LRA" button. | ||
+ | |||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | [[image: | + | [[image:VTL Bender Setup AMOB Bender New Setup.png|600px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 218: | Line 195: | ||
<td width=300> | <td width=300> | ||
− | === | + | ===Check the BLUE COLUMN Data=== |
− | + | The LRA blue column data is now filled with the MASTER LRA data. | |
+ | |||
+ | This data MUST match the X axis, Y axis, Z axis bender data at the bender - or the corrections will be incorrect. | ||
<br><br> | <br><br> | ||
− | + | ||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | [[image: | + | [[image:VTL Bender Setup AMOB After Master Data Import.png|600px]] |
− | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
Line 236: | Line 213: | ||
<td width=300> | <td width=300> | ||
− | === | + | ===Send the Corrections to the AMOB VTL File=== |
− | + | Save the Correction data to the file for the AMOB to import. | |
+ | <br><br> | ||
+ | STEP 1 - Click on Bidirectional Communication<br><br> | ||
+ | STEP 2 - Click on AUTO SEND.<br><br> | ||
+ | STEP 3 - Save the new VTL file to the network location. | ||
− | |||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | [[image: | + | [[image:VTL Bender Setup AMOB Correction.png|600px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
+ | <br><br> | ||
<table cellpadding=10> | <table cellpadding=10> | ||
Line 277: | Line 235: | ||
<td width=300> | <td width=300> | ||
− | === | + | ===Import the Correction Data at the AMOB Control=== |
− | + | Save the Correction data to the file for the AMOB to import. | |
− | + | ||
− | + | ||
<br><br> | <br><br> | ||
− | + | STEP 1 - Enter the Program Machine Configuration menu. <br><br> | |
+ | STEP 2 - Press the FARO (or it may be "VTube") button<br><br> | ||
+ | STEP 3 - Open the VTL file.<br><br> | ||
+ | |||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | [[image: | + | [[image:amob_program_machine_configuration_press_FARO.png|500px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 294: | Line 253: | ||
<td width=300> | <td width=300> | ||
− | The | + | ===AMOB Control Bender Data Updated=== |
+ | The bender data will be updated with the new values.<br><br> | ||
+ | Bend the corrected part. | ||
− | |||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | [[image: | + | [[image:AMOB bender data screen.png|500px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | ==Synchronizing the VTube-LASER and AMOB Data Before Corrections== | ||
<table cellpadding=10> | <table cellpadding=10> | ||
Line 308: | Line 273: | ||
<td width=300> | <td width=300> | ||
− | + | It is critical to be sure the blue columns contain the same data that the AMOB X Axis, Y Axis, Z axis values have before correction is applied.<br><br> | |
− | + | ||
− | <br><br> | + | To make the data the value the same for the next correction, you can press the bottom button in the Bidirectional Communications menu on the right. Be sure you do this BEFORE you measure the next corrected part.<br><br> |
− | + | ||
+ | The reason for this step is because the AMOB does not allow VTube to RECALL data in order to update the BLUE columns for the next correction. So this process must be performed manually.<br><br> | ||
+ | |||
+ | The data in the blue and the orange columns will now be identical. You can exit this window and measure the next corrected part. | ||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
− | [[image: | + | [[image:Combine Adjusted back into LRA then CLEAR Adjusted.png]]<br><br> |
+ | [[image:Adjusted data combined into blue columns.png|600px]]<br><br> | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
− | |||
− | |||
− | |||
==Other Pages== | ==Other Pages== | ||
* See [[VTube-LASER]] | * See [[VTube-LASER]] | ||
* See [[VTube-STEP]] | * See [[VTube-STEP]] | ||
− | |||
− |
Latest revision as of 17:55, 24 January 2017
About this Page
This page describes the setup and use of the VTube to AMOB communications. |
The Basics of How It Works
|
Communications Setup at the AMOB Bender
|
Setup Benderlink at VTube-STEP or VTube-LASER
Entering Benderlink Setup
|
Setup the Benderlink Network Grid for the AMOB Bender
|
How to SEND MASTER BENDER Data to the AMOB Control from VTube-STEP
You can import data into VTube-STEP then send the bender data calculated to the AMOB bender using the VTube Input/Export menu. |
At the VTube-STEP Main ScreenMove to the VTube-STEP computer and follow these steps to transfer the bender data to the AMOB.
|
At the AMOB Bender Data Export Window (inside VTube-STEP)Press the Export button to save a VTL file on the network at the shared path for the AMOB bender. |
How to SEND CORRECTION Data to the AMOB Control from VTube-LASER
After Bending the Tube
Bend a tube then measure it with VTube-LASER.
Measure the tube with VTube-LASERMeasure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.
|
Correct the AMOB with VTube-LASER - Enter BENDER SETUPFollow these steps in the VTube-LASER: Press the "BENDER SETUP button in the Navigation Pane. |
INITIAL Setup of Bender Setup WindowThe first time in this window for a new part will require these steps before you can correct the AMOB bender. STEP 1 - Set the correct bender number at the top of the window. The AMOB bender should display if you have already setup the bender protocol in the Benderlink grid.
|
Check the BLUE COLUMN DataThe LRA blue column data is now filled with the MASTER LRA data. This data MUST match the X axis, Y axis, Z axis bender data at the bender - or the corrections will be incorrect.
|
Send the Corrections to the AMOB VTL FileSave the Correction data to the file for the AMOB to import.
|
Import the Correction Data at the AMOB ControlSave the Correction data to the file for the AMOB to import.
|
AMOB Control Bender Data UpdatedThe bender data will be updated with the new values. |
Synchronizing the VTube-LASER and AMOB Data Before Corrections
It is critical to be sure the blue columns contain the same data that the AMOB X Axis, Y Axis, Z axis values have before correction is applied. To make the data the value the same for the next correction, you can press the bottom button in the Bidirectional Communications menu on the right. Be sure you do this BEFORE you measure the next corrected part. The reason for this step is because the AMOB does not allow VTube to RECALL data in order to update the BLUE columns for the next correction. So this process must be performed manually. The data in the blue and the orange columns will now be identical. You can exit this window and measure the next corrected part. |
Other Pages
- See VTube-LASER
- See VTube-STEP