Difference between revisions of "VTube-STEP v2.9.10"

From ATTWiki
Jump to: navigation, search
(Created page with "<table> <tr cellpadding=10> <td width=225> 300px ==Revision 2.9.10== Release Date: July 4, 2018<br> Build: 12 * Back to VTube-STEP * Back...")
 
(25pxNEW - HERBER Bender Setup From Solid Model Through a Network)
 
(15 intermediate revisions by one user not shown)
Line 4: Line 4:
 
[[image:vtube-step_logo_2.png|300px]]
 
[[image:vtube-step_logo_2.png|300px]]
 
==Revision 2.9.10==
 
==Revision 2.9.10==
Release Date: July 4, 2018<br>
+
Release Date: July 5, 2018<br>
Build: 12
+
Build: 14
  
  
Line 23: Line 23:
 
__TOC__
 
__TOC__
  
==[[image:Check.jpg|25px]]NEW - VTUBE-STEP MODE AUTOMATIC NEGATIVE STRAIGHT FIX DURING PARAMETRIC REBUILD==
+
==[[image:Check.jpg|25px]]NEW - HERBER Bender Setup From Solid Model Through a Network==
  
 
<table cellpadding=10 width=900>
 
<table cellpadding=10 width=900>
Line 30: Line 30:
 
<td width=400>
 
<td width=400>
  
(Note: VTube-STEP is included in the VTube-LASER license. It is used for importing model data.)<br><br>
+
We added the HERBER SOL file protocol that allows VTube-STEP to send NEW data to the HERBER benders through a network connection.
 +
<br><br>
  
Models with a 180-degree or greater bend angles can often create a very small negative straight distance value. We've added this feature to allow you to detect and fix this situation automatically by injecting a value of zero where there are negative straights.<br><br>
+
[[image:HerberSplash.png|200px]]<br><br>
 +
Use this new feature to import solid models into HERBER bender controls.<br><br>
  
Pressing YES will change the shape of the part.  However, if the negative straight is very small, then changing the shape will have no significance and will create a part that is close enough to the nominal to still be a good shape for use as MASTER data.<br><br>
+
See [[VTube HERBER Bender New Part Setup (SOL Protocol)]]
 
+
This feature also allows you to skip the fix by pressing "NO." If you do this, then you can still manually adjust the radii to smaller values after the rebuild. Of course, if you skip this fix, then VTube may have trouble generating the diameter - and may even generate and display a program error that you can usually bypass.<br><br>
+
  
 
</td>
 
</td>
Line 42: Line 42:
 
<td>
 
<td>
  
[[image:vts_v2.9.9_automatic_negative_straight_fix_at_rebuild.png|600px]]<br><br>
+
 
 +
[[image:vtl_v2.9.10_herber_sol_output.png|600px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 49: Line 50:
 
<br><br>
 
<br><br>
  
 
+
==[[image:Check.jpg|25px]]FIX- VTUBE-STEP WINDOW STARTUP POSITION==
==[[image:Check.jpg|25px]]FIX- VTUBE-STEP MODE COLLECTION FEATURE SELECTION ISSUE==
+
  
 
<table cellpadding=10 width=1000>
 
<table cellpadding=10 width=1000>
Line 56: Line 56:
  
 
<td width=400>
 
<td width=400>
(Note: VTube-STEP is included in the VTube-LASER license. It is used for importing model data.)<br><br>
+
The VTube-STEP Window did not always maximize properly at startup.<br><br>
 +
<b>This is fixed in this version.</b>
 +
</td>
  
We found issues with the collected objects in VTube-STEP mode.<br><br>
+
<td>
* For example, the selected collected object (see the orange object) would never delete from the screen - even if the operator selected it and pressed delete.<br><br>
+
[[image:vts_v2.9.10_window_maximized.png|700px]]<br><br>
* This issue could cause index errors in the Collection Features list memory displayed in the grid.<br><br>
+
</td>
* The Collection Features Grid would not update automatically after a delete of the models on the screen.<br><br>
+
</tr>
  
All of these issues have been fixed.
+
</table>
 +
<br><br>
 +
 
 +
==[[image:Check.jpg|25px]]FIX- VTUBE-STEP ASSEMBLY CONTROL WINDOW ISSUE==
 +
 
 +
<table cellpadding=10 width=1000>
 +
<tr valign=top>
 +
 
 +
<td width=400>
 +
The Assembly Control window would display a list index error during its first load or when adding a new part to the assembly.<br><br>
 +
<b>This is fixed in this version.</b>
 
</td>
 
</td>
  
 
<td>
 
<td>
[[image:vvts_2.9.9_collected_object_selection.png|700px]]<br><br>
+
[[image:vts_v2.9.10_assembly_control_window.png|700px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 22:36, 5 July 2018

Vtube-step logo 2.png

Revision 2.9.10

Release Date: July 5, 2018
Build: 14


Vtube-step v2.9 mainscreen headerassembly purple.png



Contents


Check.jpgNEW - HERBER Bender Setup From Solid Model Through a Network

We added the HERBER SOL file protocol that allows VTube-STEP to send NEW data to the HERBER benders through a network connection.

HerberSplash.png

Use this new feature to import solid models into HERBER bender controls.

See VTube HERBER Bender New Part Setup (SOL Protocol)


Vtl v2.9.10 herber sol output.png



Check.jpgFIX- VTUBE-STEP WINDOW STARTUP POSITION

The VTube-STEP Window did not always maximize properly at startup.

This is fixed in this version.

Vts v2.9.10 window maximized.png



Check.jpgFIX- VTUBE-STEP ASSEMBLY CONTROL WINDOW ISSUE

The Assembly Control window would display a list index error during its first load or when adding a new part to the assembly.

This is fixed in this version.

Vts v2.9.10 assembly control window.png