− | ===[[image:Check.jpg|25px]] NEW: | + | |
+ | ===[[image:Check.jpg|25px]] NEW: Import Supravision Files=== | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | + | Supravision files are stored on Supravision-based measuring centers. Customers that migrate to VTube-LASER from Supravision will not lose any of their project data because you can use Supravision project files to setup VTube-LASER. | |
+ | <br><br> | ||
+ | All appropriate values are imported. (See the Supravision Protocol entry below). | ||
+ | <br><br> | ||
+ | For old-style SV files created by the DOS version of Supravision, we can supply a [[SVFILE]] Converter program to convert the files/folders to newer long filenames. | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:vtube- | + | [[image:vtube-laser_1_57_importSV.jpg|300px]]. |
</td> | </td> | ||
</tr> | </tr> | ||
Line 29: | Line 34: | ||
<br><br> | <br><br> | ||
− | ===[[image:Check.jpg|25px]] NEW | + | ===[[image:Check.jpg|25px]] NEW: Transfer New Values in Supravision Protocol === |
+ | |||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | + | New values are included in Supravision file transfers and Supravision Network transfers from benders (imports/exports/bender corrections): | |
+ | <br><br> | ||
+ | |||
</td> | </td> | ||
− | <td> | + | <td width=300> |
− | + | * Comment 1 | |
− | + | * Comment 2 | |
+ | * Default Radius | ||
+ | * A End Offset | ||
+ | * B End Offset | ||
+ | * Tube Elongation Percentage | ||
+ | * Fixed Springback | ||
+ | * Proportional Springback | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ===[[image:Check.jpg|25px]] NEW: | + | <br><br> |
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master=== | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | + | You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender. | |
<br><br> | <br><br> | ||
+ | The Bender Setup toolbar on the right has a new button that allows you to RECALL MASTER XYZ from a bender to create the MASTER data in VTube. | ||
+ | <br><br> | ||
+ | Before the transfer occurs, VTube will ask you to confirm that you mean to overwrite the MASTER data in VTube.<br><br> | ||
+ | If the incoming bender data does not have MASTER XYZ data, then VTube will warn you and stop the transfer. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_1_57_recallbendermaster.jpg|300px]]. | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Bender Setup Redesigned=== | ||
+ | |||
+ | [[image:vtube-laser_1_57_bendersetup_bendernumber.jpg|500px]] | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The Bender Setup user interface menu was redesigned. | ||
+ | <br><br> | ||
+ | * The bender number font size is larger. | ||
+ | * The toolbar on the right is more compact. | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Negative Lengths or Bend Angles are ZEROED=== | ||
+ | |||
+ | [[image:vtube-laser_1_57_bendersetup_zeroedlength.jpg|500px]] | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | Bender Lengths and angles that calculate negative values are zeroed. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Springback Compensation for Corrections === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone. | ||
+ | <br> | ||
+ | * For example, if the adjustment value for a 90 degree bend is found to be +3 degrees, then the springback compensation added to the bend is calculated based on 3 degrees, not 93 degrees. | ||
+ | <br> | ||
+ | * The springback compensation works for both positive and negative adjustments. A positive adjustment will add springback. A negative adjustment will remove springback. | ||
+ | <br> | ||
+ | * VTube will not use springback for small adjustment values. The "Use springback compensation for bend adjustments greater than or equal to:" setting in the Bender Setup menu controls this. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_1_57_bendersetup_automatic_adjustment_springback.jpg|300px]]<Br><br> | ||
+ | [[image:vtube-laser_1_57_bendersetup_automatic_adjustment_springback_limit.jpg|300px]]. | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Transfer Master LRA to Setup LRA with Springback Compensation === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | When transferring data from the VTube MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero.</td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_1_57_bendersetup_master2setup_autospringback.jpg|300px]]. | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Part Name in Toolbar === | ||
+ | [[image:vtube-laser_1_57_toolbar_filename.jpg|500px]] | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The current part name is now displayed in the toolbar below the VTube-LASER logo. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW- Springback Values Transfer from Overbend === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | VTube-LASER can now receive springback data from Overbend with the press of a single button in the Overbend Calculator.<br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser_1_57_overbend_sendvaluestovtube.jpg|300px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | [[image:vtube-laser_1_57_overbend_transfer.jpg|500px]] | ||
<br><br> | <br><br> | ||
===[[image:Check.jpg|25px]] ENHANCED - Other Changes === | ===[[image:Check.jpg|25px]] ENHANCED - Other Changes === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | * Added high precision angular decimal places value in System Option/Math | ||
+ | <br><br> | ||
+ | * Made Comments to display after the file has loaded and the graphic is displayed on the screen. | ||
+ | <br><br> | ||
+ | * The BEST FIT alignment procedure is fine tuned to run about 6 times faster than in previous versions with no loss of accuracy. | ||
+ | <br><br> | ||
+ | * Improvements/fixes to Supravision RECALL procedures. | ||
+ | |||
+ | [[image:vtube-laser_1_57_benderrecall.jpg|200px]]<br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser_1_57_highprec_angledecimalplaces.jpg|300px]]<br><br> | ||
+ | [[image:vtube-laser_1_57_partcomments.jpg|300px]]<br><br> | ||
+ | [[image:vtube-laser_1_57_bestfit_image.jpg|300px]]<br><br> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
Latest revision as of 02:08, 13 January 2011
Revision 1.57Back to VTube-LASER |
NEW: Import Supravision Files
Supravision files are stored on Supravision-based measuring centers. Customers that migrate to VTube-LASER from Supravision will not lose any of their project data because you can use Supravision project files to setup VTube-LASER.
|
NEW: Transfer New Values in Supravision Protocol
New values are included in Supravision file transfers and Supravision Network transfers from benders (imports/exports/bender corrections):
|
|
NEW: Recall the BENDER MASTER XYZ to Establish the VTube Master
You can now ask the bender to give you the MASTER XYZ data if that data exists on the bender.
|
ENHANCED: Bender Setup Redesigned
The Bender Setup user interface menu was redesigned.
|
ENHANCED: Negative Lengths or Bend Angles are ZEROED
Bender Lengths and angles that calculate negative values are zeroed. |
ENHANCED: Springback Compensation for Corrections
The springback compensation values in the Bender Setup menu are now calculated based on the adjustment value alone.
|
NEW: Transfer Master LRA to Setup LRA with Springback Compensation
When transferring data from the VTube MASTER LRA to the BENDER SETUP LRA, automatic springback compensation is automatically applied if the springback values are non-zero. |
NEW: Part Name in Toolbar
The current part name is now displayed in the toolbar below the VTube-LASER logo. |
NEW- Springback Values Transfer from Overbend
VTube-LASER can now receive springback data from Overbend with the press of a single button in the Overbend Calculator. |
ENHANCED - Other Changes
|