Difference between revisions of "VTube-LASER v1.68"

From ATTWiki
Jump to: navigation, search
(25px Other Changes)
(25px Other Changes)
 
(6 intermediate revisions by one user not shown)
Line 16: Line 16:
  
 
===[[image:Check.jpg|25px]] NEW: Excel Report Builder===
 
===[[image:Check.jpg|25px]] NEW: Excel Report Builder===
 +
[[image:vtube-laser_report_excel_button.jpg|300px]]
  
[[image:vtube-laser_excel.jpg|500px]]
 
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
Line 29: Line 29:
 
</tr>  
 
</tr>  
 
</table>
 
</table>
 +
[[image:vtube-laser_excel.jpg|500px]]
  
 
===[[image:Check.jpg|25px]] REVISED: Overbend Calculator===
 
===[[image:Check.jpg|25px]] REVISED: Overbend Calculator===
Line 36: Line 37:
 
<td width=300>
 
<td width=300>
 
The Overbend Calculator was redesigned and improved.
 
The Overbend Calculator was redesigned and improved.
<br><br>
 
When Cut Plane is active a Cut Plane icon displays at the bottom of the Navigation pane.  (See the orange arrow above.)
 
<br><br>
 
 
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 76: Line 73:
  
  
===[[image:Check.jpg|25px]] NEW - Add After Row in MASTER XYZ===
+
 
 +
 
 +
===[[image:Check.jpg|25px]] Other Changes===
 
<table cellpadding=10>
 
<table cellpadding=10>
  
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* Now add rows after the current row in Master XYZ data.  This allows users to add a row after the last row of XYZ coordinates.
+
* The radius values now correctly copy back to XYZ radius values when performing a reverse calc.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_addafterthisrow.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>
  
</table>
+
<tr valign=top>
 
+
<td width=300>
===[[image:Check.jpg|25px]] Other Changes===
+
* It is now possible to edit the blue-column bend ANGLE and ANGLE ADJUSMENT data in the Bender Setup menu.
<table cellpadding=10>
+
</td>
 +
<td width=300>
 +
</td>
 +
</tr>
  
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* The radius values now correctly copy back to XYZ radius values when performing a reverse calc.
+
* A new LRA Master to Measured report is added.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 103: Line 104:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* It is now possible to edit the blue-column bend ANGLE and ANGLE ADJUSMENT data in the Bender Setup menu.
+
* Rotation corrections are always shift to the shortest side of the clock.  For example +359 degree is reset to -1.0.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 111: Line 112:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* A new LRA Master to Measured report is added.
+
* Now the tangent point/midpoint inspection grid is automatically set with the default tolerance when the grid grows.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
 
</td>
 
</td>
 
</tr>
 
</tr>
 +
 +
  
  

Latest revision as of 23:38, 9 August 2011

Vtube-laser logo.jpg

Revision 1.68

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser screen 1 68.jpg

Contents


Check.jpg NEW: Excel Report Builder

Vtube-laser report excel button.jpg

VTube-LASER can now build a Excel report quickly. This is useful for taking your reports even further for Gage R&R an custom reports.

Vtube-laser excel.jpg

Check.jpg REVISED: Overbend Calculator

Vtube-laser overbend.jpg

The Overbend Calculator was redesigned and improved.

Check.jpg NEW: More Option in the Bender Setup

Vtube-laser bendersetup saveSV.jpg

Bender Setup can now save Supravision files from the bender setup data to the network. The menu can send either bender data with corrections or bender data without corrections. For uni-directional benders, you can merge Adjustments back into the bender data after sending data to the bender.

Check.jpg NEW: Added Tab Menus in the MASTER XYZ Menu

New tab menus with new options are now placed in separate tab menus in the Master XYZ menu.

Vtube-laser master xyz tabmenus setpoints.jpg
Vtube-laser master xyz tabmenus.jpg
Vtube-laser master xyz tabmenus splitbend.jpg




Check.jpg Other Changes

  • The radius values now correctly copy back to XYZ radius values when performing a reverse calc.
  • It is now possible to edit the blue-column bend ANGLE and ANGLE ADJUSMENT data in the Bender Setup menu.
  • A new LRA Master to Measured report is added.
  • Rotation corrections are always shift to the shortest side of the clock. For example +359 degree is reset to -1.0.
  • Now the tangent point/midpoint inspection grid is automatically set with the default tolerance when the grid grows.



Check.jpg Issues with this version fixed in newer versions

  • No known issues



Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg