Difference between revisions of "VTube-LASER v1.85.1"
(→25px ENHANCED: Added PLUS and MINUS tolerances for end lengths) |
(→25px ENHANCED: Added PLUS and MINUS tolerances for End Lengths) |
||
(3 intermediate revisions by one user not shown) | |||
Line 20: | Line 20: | ||
* See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version. | * See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version. | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Added PLUS and MINUS tolerances for End Lengths=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | |||
+ | [[image:vtube-laser-1.85.1_endlength_posneg_tolerances_gridcloseup.png|400px]]<br><br> | ||
+ | |||
+ | |||
+ | Some qualification specs have unique tolerances for positive and negative lengths, so we added + and - tolerances for the end lengths.<br><br> | ||
+ | |||
+ | * The End Length grid in the Inspection menu has minus as well as plus tolerances in the grid. | ||
+ | * The tolerance envelopes in the graphics viewport shows both the positive and negative tolerances with transparent cylinders that run in both directions. | ||
+ | * The Inspection report template includes the + and - values in the End Length reporting. | ||
+ | <br><br> | ||
+ | [[image:vtube-1.85.1_endlength_plusminustolerance_envelopes.png|400px]] | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | |||
+ | [[image:vtube-1.85.1_endlength_plusminustolerance.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: SolidWorks Builder - End Offsets Added=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | The SolidWorks tube builder can now:<br> | ||
+ | * Build extruded diameter offsets at the ends of the tube.<br><br> | ||
+ | [[image:vtube-step-1.84.1_buildsolidworks_negativeoffset.png|400px]]<br> | ||
+ | |||
+ | <br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-step-1.84.1_PreSolidWorksPart.png|400px]]<br><br> | ||
+ | [[image:vtube-step-1.84.1_buildsolidworks_positiveoffset.png|400px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
<br><br> | <br><br> | ||
Line 85: | Line 128: | ||
<br><br> | <br><br> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
===[[image:Check.jpg|25px]] NEW: Export Dialog Windows With Configurable Paths=== | ===[[image:Check.jpg|25px]] NEW: Export Dialog Windows With Configurable Paths=== |
Latest revision as of 02:56, 7 January 2014
Revision 1.85.1
|
- See VTube-LASER Customer Support Page to download the latest version.
ENHANCED: Added PLUS and MINUS tolerances for End Lengths
|
ENHANCED: SolidWorks Builder - End Offsets Added
The SolidWorks tube builder can now:
|
FIXED: Memory Leaks
A few heavy-use customers were reporting that the Alignment feature, if used for hours repeatedly, would eventually cause a lock to the software. We discovered that VTube would eventually run out of Windows memory if used for extended periods of time because several additional megabytes of memory was used but never released during each alignment.
This fix can be proved by running the Task Manager Performance menu, and viewing the "Available" memory value during an alignment. |
ENHANCED: Repaired and Improved Benderlink Setup Menu
We discovered issues with the Benderlink Setup menu, where edited data was not always stored after it was changed in the grid. This has been repaired. All data entered is saved.
|
ENHANCED: Improved System Options Menu
The System Options menu is changed:
|
NEW: Export Dialog Windows With Configurable Paths
|
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor