Difference between revisions of "VTube-STEP v2.3"

From ATTWiki
Jump to: navigation, search
(Created page with "<table> <tr cellpadding=10> <td width=225> 300px ==Revision 2.3== * Back to VTube-STEP * Back to VTube-STEP Revisions * Back to VTube...")
 
(25px ENHANCED: Increase Maximum Point Limit from 102 up to 202 (200 Bends))
 
(90 intermediate revisions by one user not shown)
Line 6: Line 6:
 
* Back to [[VTube-STEP]]
 
* Back to [[VTube-STEP]]
 
* Back to [[VTube-STEP Revisions]]
 
* Back to [[VTube-STEP Revisions]]
* Back to [[VTube Software Updates]] (for LASER Mode)
+
* Switch to VTube-LASER updates in [[VTube Software Updates]]
* Back to [[VTube-LASER]]
+
* Switch to [[VTube-LASER]]
  
 
</td>
 
</td>
Line 21: Line 21:
 
<br>
 
<br>
  
 +
==This Update is Important For...==
 +
 +
 +
# '''Customers that use springback compensation of any form in VTube'''<br>
 +
# '''Customers that use tube elongation percentage to predict cut length and unbending lengths'''
 +
# '''Customers that experienced image draw problems in the REPORT window'''
  
==[[image:Check.jpg|25px]] NEW: Springback-Compensated LRA Grid==
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=400>
 
VTube-STEP graphics are now '''3 TIMES''' faster than in previous versions.  Plus the graphics are more stable.<br><br>
 
</td>
 
<td width=300>
 
[[image:HVAC_Double_180Bend_VTS.png|400px]]
 
</td>
 
</tr>
 
</table>
 
  
==[[image:Check.jpg|25px]] NEW: Robomac Wire-form Bender Communications==
 
<table>
 
<tr>
 
<td width=400>
 
 
<br><br>
 
<br><br>
[[VTube-LASER]] and [[VTube-STEP]] can now communicate with Robomac wire-form bender controls using the Robomac PART data file protocol.<br><br>
 
[[VTube-STEP]] can EXPORT data to Robomac benders using the protocol.  [[VTube-LASER]] can SEND and RECALL data to/from Robomac benders for full corrections loops.<br><br>
 
See the [[VTube Robomac Communications]] knowledgebase page for a guide to setup the VTube for communications with benders using the Robomac PART file protocol.
 
</td>
 
<td>
 
[[image:vtube_communication_robomac_splash.png|500px]]
 
</td>
 
</tr>
 
</table>
 
  
==[[image:Check.jpg|25px]] NEW: WIREFRAME Feature For the MODELS==
+
==[[image:Check.jpg|25px]] FIX: Tube Image Display and Refresh in the Report Window==
<table cellpadding=10>
+
<table cellpadding=10 width=700>
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
 
The WIREFRAME feature allows you to toggle a wireframe on the surface of the solid models.<br><br>
 
 
The new feature can often give better clarity for straights and arc sections in the tube.<br><br>
 
 
(This was a customer-requested feature.)
 
 
 
</td>
 
 
<td width=300>
 
<td width=300>
[[image:vtube-step-2.2_wireframe_feature.png|400px]]
+
* The Automatic Image Refresh checkbox state was not properly remembered and restored between program loads/unloads. This has been fixed.<br><br>
</td>
+
* The refresh image logic has been updated to handle slower computers that don't clear the window fast enough to draw the image properly.
</tr>
+
  
 
+
<br><br>
</table>
+
'''There seems to be a wide variance in computer graphics performance among customers.  If your computer still has problems refreshing the tube image properly in the report window, please let us know by sending a sample screen image of the issue.'''
 
+
 
+
 
+
 
+
 
+
==[[image:Check.jpg|25px]] NEW: Popup Menu Options for Viewport==
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=400>
+
There are several new options added to the viewport popup menu.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-step_v2.2_popup_menu_002.png|400px]]
+
[[image:vtube_v2.3_reportwindow_imagerefresh.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
 
 
</table>
 
</table>
  
==[[image:Check.jpg|25px]] NEW: X, Y, and Z Span Values in Reports==
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=400>
 
The SPAN values of each of the part's axes can be reported on as of this version.  This means that the total volume the part takes in its current orientation can be reported in three 3D distances.<br><br>
 
(This was a customer-requested feature.)
 
</td>
 
<td width=400>
 
[[image:vtube-step_xyzspans_report.png|400px]]<br><br>
 
</td>
 
</tr>
 
</table>
 
  
==[[image:Check.jpg|25px]] NEW: Import UTE Bender XML File Data ==
+
==[[image:Check.jpg|25px]] NEW: Press Enter to Set Point Count==
<table cellpadding=10>
+
<table cellpadding=10 width=700>
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
 
VTube can now import the centerline XYZ data from UTE XML files.<br><br>
 
The data imported is centerline XYZ data, diameter, linear unit used, and radii.<br><br>
 
[[image:UTEbender.png|300px]]<br><br>
 
(This was a customer-requested feature.)<br><br>
 
</td>
 
 
<td width=300>
 
<td width=300>
[[image:vtube-step_v2.2_ute_xml_import.png|400px]]
+
Users like to press the Enter key after entering the point count in the XYZ grids, so we've allowed for that action VTube.<br><br>'''When entering a value in the Point Count box and you press the ENTER key, VTube automatically presses the SET button for you.'''<br><br>
</td>
+
<br><br>
</tr>
+
  
</table>
 
 
==[[image:Check.jpg|25px]] NEW: MOUSE WHEEL CLICKS Toggle VTube between ORBIT Mode and PAN Mode ==
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=400>
 
'''Play the video on the right to see this new feature working.'''<br><br>
 
The graphic viewport now switches between ORBIT mode and PAN mode when you press the mouse wheel button.<br><br>
 
Press right click to change back to SELECT mode from either ORBIT or PAN.<br><br>
 
(This was a customer-requested feature.)
 
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser-2.2_mousewheel_orbitpan_video.png|400px|link=http://www.advancedtubular.com/vtube-laser/vtube-v2.2_mousewheel_control.mp4]]
+
[[image:vtube_v2.3_enter_sets_point_count.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
 
</table>
 
</table>
  
==[[image:Check.jpg|25px]] NEW: Improved Folder Selection Dialog ==
+
==[[image:Check.jpg|25px]] ENHANCED: Increase Maximum Point Limit from 102 up to 202 (200 Bends) ==
[[image:tube-laser-2.2_folderselection_newpath_dialog.png|800px]]
+
<table cellpadding=10 width=700>
<table cellpadding=10>
+
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
 
In the Path Manager's NEW PATH window, the PATH dialog was not very user friendly compared to the open dialog window, so we changed the folder selection dialog to look like an open file dialog.<br><br>
 
It is much easier to view and use than before.<br>
 
</td>
 
 
<td width=300>
 
<td width=300>
[[image:vtube-laser-2.2_folderselection_dialog_before_after.png|400px]]
+
One customer had parts that required over 100 bends, so we increased the maximum number of bends allowed in VTube to 200.<br><br>
</td>
+
Note: Use the most powerful computer you can when the bend count is high.  For drawing models with more than 100 bends we strongly recommend an engineering-workstation level computer.<br><br>
</tr>
+
<br><br>
  
</table>
 
 
==[[image:Check.jpg|25px]] REPAIR: Default Project SAVE is FIXED ==
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=400>
 
This version includes an important fix to a bug introduced accidentally in 2.1.x that could corrupt the default configuration file when operators saved new defaults.<br>
 
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-2.2_setprojectdefaultstate_feature.png|400px]]
+
[[image:vtube_2.3_200bends.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
 
</table>
 
</table>
  
==[[image:Check.jpg|25px]] ENHANCED: Calculation Precision Increased Significantly for Short Straights==
+
==[[image:Check.jpg|25px]] ENHANCEMENT: Blank White Cells Replace Dashes and Zeros==
<table cellpadding=10>
+
<table cellpadding=10 width=700>
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
 
The calculation precision for short straights and very small holes is MUCH improved in this version.<br><br>
 
The end straight and the straight between bends 1 and 2 shown in the image on the right are 0.001 inches (0.0254 mm) long. (Click on the image to see a closeup.)</td>
 
<td width=400>
 
[[image:vtube-step_v2.2_calculation_short_straight.png|400px]]
 
</td>
 
</tr>
 
</table>
 
 
==[[image:Check.jpg|25px]] NEW: Detects New Paths to Allow to ADD to Path Manager ==
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=400>
 
As of this version, when VTube detects a new path from any OPEN or SAVE dialog that is not already in the Path Manager, it will offer to store the new path in the Path Manager with this ADD dialog.<br><br>
 
</td>
 
 
<td width=300>
 
<td width=300>
[[image:vtube-laser-2.2_offer_to_add_path.png|400px]]
+
The grid interface is now cleaner than in previous versions.  Previous versions would show zeros for the end point radii, and also dashes in LRA cells that are not used.<br><br>
</td>
+
This has been changed so that all of these cells are now blank.<br><br>
</tr>
+
This implies that nothing goes in these cells - and prevents new users from thinking they have to enter data in those cells.
 
+
</table>
+
 
+
 
+
==[[image:Check.jpg|25px]] NEW: Save VTube Project Files in Older File Versions (v2.2 - Beta 9) ==
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=400>
+
VTube now allows you to save projects in one of over 50 older project file versions for compatibility with older versions of VTube.<br><br>
+
The feature is available whenever the Save Dialog appearsChoose the file version in the "Save as type" box.<br><br>
+
Whenever VTube senses that you are about to save a project file in an older version, it will warn you with a dialog like the one shown below.<br><br>
+
[[image:vtube-2.2_OlderFileVersion_WarnDialog.png|300px]]
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-2.2_SaveDialog_OlderFileVersion.png|400px]]
+
[[image:vtube_2.3_blankcells_xyz_lra.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
 
</table>
 
</table>
  
 
+
==[[image:Check.jpg|25px]] FIX: Springback Compensation Issues Repaired==
==[[image:Check.jpg|25px]] FIXED: Erasure Issue of Collected Entities in STEP Mode (v2.2 - Beta 10) ==
+
<table cellpadding=10 width=700>
<table cellpadding=10>
+
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
 
Previous versions of VTube-STEP could sometimes randomly erase collected entities during the centerline calculation.<br><br>
 
This issue has been fixed.<br><br>
 
</td>
 
 
<td width=300>
 
<td width=300>
[[image:vtube_collectedentity.png|400px]]
+
'''If you use springback compensation in VTube, then this upgrade is important for you.'''<br><br>
</td>
+
When VTube-STEP calculated springback into bender values, it incorrectly doubled the springback values. This has been repaired.<br><br>  
</tr>
+
Also, the springback-compensated LRA values would display in the MASTER LRA grid. This was never the intent of the calculation, so this has been fixed by adding a second grid with Springback-Compensated LRA data.
 
+
</table>
+
 
+
 
+
 
+
 
+
==[[image:Check.jpg|25px]] NEW: Popup Menu Additions (v2.2 - Beta 13) ==
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=400>
+
The popup menu now includes toggles for Auto Zoom and Perspective mode.<br><br>(This was a customer-requested feature.)
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-step_v2.2_popup_menu.png]]
+
[[image:vtube_2.3_springback_report.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
 
</table>
 
</table>
  
 
+
==[[image:Check.jpg|25px]] NEW: Springback-Compensated LRA Grids==
 
+
<table cellpadding=10 width=700>
==[[image:Check.jpg|25px]] FIXED: Bender Output Path - SV Network Tab Menu (v2.2 - Beta 14-20) ==
+
<table cellpadding=10>
+
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
This menu now correctly uses the Benderlink network setup path when you select a bender number.<br><br>
+
We've added new grids of LRA data:<br><br>
The output data now always uses the springback values in Part Setup to calculate the outgoing straights and bends.<br><br>
+
Both VTube-STEP and VTube-LASER now have Springback-Compensated grids in the Tube data, Master Tube data, and the Measured Tube data menus.<br><br>
The output data now compresses the bender data if split bends are present. (For example two adjacent 90 degree bend angles become a single 180.)
+
Also, the new grids have popup menus that allow you to copy any part of the grid.<br><br>
 
+
[[image:vtube_v2.2_springback_grid_popupmenu.png|300px]]<br><br>
 +
VTube uses the FIXED and PROPORTIONAL springback variables in the Part Setup menu to calculate the springback compensated values in these grids.<br><br>
 +
If the proportional or fixed values are NON-ZERO, then you will see compensated values in these new grids.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-step_v2.2_benderoutput_SVnetwork.png|400px]]
+
[[image:vtube-step_v2.2_springback_compensated_grid.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
 
</table>
 
</table>
  
==[[image:Check.jpg|25px]] CHANGE: Security Change Required by New Windows Security Updates - Network Socket Logic (v2.2 Beta 20) ==
+
==[[image:Check.jpg|25px]] NEW: Multi-Elongation Percentage Compensation Setup==
<table cellpadding=10>
+
<table cellpadding=10 width=700>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
We made an important change to the Network License Manager networking portion of the code for Windows compliance.<br><br>
+
VTube-STEP now allows each bend to have a unique tube elongation percentage - which is used to calculate correct CUT LENGTHS and UNBENDING LENGTHS<br><br>
VTube used to open an IP socket using 0.0.0.0, then assign a working IP address based on the configuration.<br><br>
+
Use the popup menus in either the PART SETUP or the XYZ grids to get to the setup window.<br><br>
As of November 2015, some Windows started throwing a critical error to VTube when VTube attempted to open the IP connection like this. So now VTube opens sockets with at least a local address of 127.0.0.1 - which is allowed by Windows.<br><br>
+
[[image:vtube_v2.2_XYZpopup_multielongationsetup.png|300px]]<br><br>
 +
A new checkbox is added at the bottom of Part Setup to allow this feature to be activated.<br><br>
 +
[[image:vtube_v2.2_partsetup_multielongationsetup_switch.png|300px]]<br><br>
 +
If the checkbox is unchecked, then the single Tube Elongation % value is used to calculate elongation for all bends.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:blueethernetcable_rj45connector.png|400px]]
+
[[image:vtube_v2.2_multielongation_setup_window.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
 
</table>
 
</table>
  
 
+
==[[image:Check.jpg|25px]] ENHANCEMENT: Springback Compensation Calculation in the Outgoing Bender Data Is Now Optional==
 
+
<table cellpadding=10 width=700>
==[[image:Check.jpg|25px]] ENHANCEMENT: Compressed Bender Data Sent to Benders When Split Bend is Active (v2.2 Beta 20) ==
+
<table cellpadding=10>
+
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
 
Split Bends are used for any two adjacent bends that form a single larger angle bend.  For example, they are used for models with 180 degree bends.  VTube must form a centerline with two 90 degree bend angles to solve for centerline intersections.<br><br>
 
However, the LRA data sent to the bender must be compress each split bend back to a single bend before sending it to the bender.<br><br>
 
So when split bends are found in a tube when sending Supravision Network data to a bender, VTube-STEP now assumes that they must be recombined in the LRA data before sending that data to the bender in the Bender Output menu.
 
</td>
 
 
<td width=300>
 
<td width=300>
[[image:vtube-step_v2.2_splitbend_compressed_data_to_bender.png|400px]]
+
This feature adds springback compensation into the outgoing LRA data. In previous versions it was not optional.
</td>
+
</tr>
+
  
</table>
+
For some benders (for example, the Eaton Leonard Lightspeed) this addition is NOT recommended because this causes the springback to be added by ''both'' VTube and the bender.  This doubles the compensation - which is incorrect.
  
 
+
If you're not sure if you should use this option, then test how your bender uses the springback compensation values by entering non-zero Springback values in VTube's Part Setup menu, then send data with this feature activated. If the bend values display with the overbend doubled, then you know that the control handles the springback compensation automatically.
 
+
==[[image:Check.jpg|25px]] NEW: Springback Table Creates a Database of Values for Reuse (v2.2 Beta 23) ==
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=400>
+
The new Springback Table lets you store springback and elongation values for reuse in other projects.<br><br>
+
The values are stored in a persistent configuration file that keeps the values the same between projects.<br><br>
+
Right click on the white column in the Part Setup menu to access the new table.<br><br>
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube_springback_table.png|400px]]
+
[[image:vtube-step_v2.3_benderoutput_svnetwork_springbackoption.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
 
</table>
 
</table>
  
 
+
==[[image:Check.jpg|25px]] ENHANCEMENT: Keep the Previous Custom Default Setup During Upgrades==
==[[image:Check.jpg|25px]] NEW: Alpine and CSM M4 Export Filenames Are Now Limited to 20 Characters Maximum (v2.2 Beta 30) ==
+
<table cellpadding=10 width=700>
<table cellpadding=10>
+
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
 
Alpine and CSM M4 controls cannot use more than 20 characters in the part filename, so VTube-STEP and VTube-LASER will stop any export with filenames that have too many characters.</td>
 
 
<td width=300>
 
<td width=300>
[[image:vtube-step_v2.2_limit_alpine_filename_length.png|400px]]
+
If you've made changes to your default settings, you will want to skip installing a new set of configuration files. This version allows you to skip the installation of new configuration files with new choices in the installation file.
</td>
+
</tr>
+
  
</table>
+
In addition to updating the main program files, you can now also control installation of:
  
 +
* Initial Configuration Files
 +
* Sample Files
 +
* Language Files
 +
* Report Templates
 +
<br><br>
 +
For example, if you changed the default setup in any way, then you should skip the installation of initial configuration files.  VTube can run fine with older configurations. 
  
==[[image:Check.jpg|25px]] CHANGE: Default LRA Rotations Set to 0 Rather than -90 (v2.2 Beta 30) ==
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=400>
 
The LRA grid now shows default rotations of 0 degrees rather than -90 degrees.  This solves issues where it make sense to start with 0 degrees of rotation when entering bender data to calculate XYZ centerline coordinates.<br><br></td>
 
<td width=300>
 
[[image:vtube-step_v2.2_rotationszero_default.png|400px]]
 
 
</td>
 
</td>
</tr>
 
</table>
 
 
 
 
==[[image:Check.jpg|25px]] NEW: Display Unbent Tube Only ==
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=400>
 
Now you can display the unbent tube alone by using this new switch in the viewport pop-up menu.</td>
 
 
<td width=300>
 
<td width=300>
[[image:VTS_v2.2_drawunbentonly.png|400px]]
+
[[image:vtube-step_v2.3_installation_options.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
 
</table>
 
</table>
 
==[[image:Check.jpg|25px]] Miscellaneous Changes==
 
 
* Save Project now no longer displays the VTube Path Manager or Save Dialog when it already knows the project filename (listed in the project filename box in the upper left corner).<br>
 
* The installation program will no longer overwrite the previous persistent configuration for VTube.  For example, you will no longer have to setup the Network License Manager values every time VTube is installed.  You will no longer have to reconfigure these persistent values every update.  (beta 14)<br>
 
* FIX to radius changes in the LRA Grid: The LRA grid now stores any manually entered radius value change properly.  In previous versions, a manually entered radius change in the LRA would be stored improperly in the next row down.<br>
 
* Updated the German language file.<br>
 
* Updated the Chinese language file.<br>
 
* Updated the Japanese language file.<br>
 
* Fixed incorrect English captions in the user interface.<br>
 
 
<br><br>
 
  
 
==Other==
 
==Other==

Latest revision as of 00:06, 12 February 2016

Vtube-step logo 2.png

Revision 2.3

Vtube-step-1.87 screenimage.png

Contents



This Update is Important For...

  1. Customers that use springback compensation of any form in VTube
  2. Customers that use tube elongation percentage to predict cut length and unbending lengths
  3. Customers that experienced image draw problems in the REPORT window




Check.jpg FIX: Tube Image Display and Refresh in the Report Window

  • The Automatic Image Refresh checkbox state was not properly remembered and restored between program loads/unloads. This has been fixed.

  • The refresh image logic has been updated to handle slower computers that don't clear the window fast enough to draw the image properly.



There seems to be a wide variance in computer graphics performance among customers. If your computer still has problems refreshing the tube image properly in the report window, please let us know by sending a sample screen image of the issue.

Vtube v2.3 reportwindow imagerefresh.png


Check.jpg NEW: Press Enter to Set Point Count

Users like to press the Enter key after entering the point count in the XYZ grids, so we've allowed for that action VTube.

When entering a value in the Point Count box and you press the ENTER key, VTube automatically presses the SET button for you.



Vtube v2.3 enter sets point count.png

Check.jpg ENHANCED: Increase Maximum Point Limit from 102 up to 202 (200 Bends)

One customer had parts that required over 100 bends, so we increased the maximum number of bends allowed in VTube to 200.

Note: Use the most powerful computer you can when the bend count is high. For drawing models with more than 100 bends we strongly recommend an engineering-workstation level computer.



Vtube 2.3 200bends.png

Check.jpg ENHANCEMENT: Blank White Cells Replace Dashes and Zeros

The grid interface is now cleaner than in previous versions. Previous versions would show zeros for the end point radii, and also dashes in LRA cells that are not used.

This has been changed so that all of these cells are now blank.

This implies that nothing goes in these cells - and prevents new users from thinking they have to enter data in those cells.

Vtube 2.3 blankcells xyz lra.png

Check.jpg FIX: Springback Compensation Issues Repaired

If you use springback compensation in VTube, then this upgrade is important for you.

When VTube-STEP calculated springback into bender values, it incorrectly doubled the springback values. This has been repaired.

Also, the springback-compensated LRA values would display in the MASTER LRA grid. This was never the intent of the calculation, so this has been fixed by adding a second grid with Springback-Compensated LRA data.

Vtube 2.3 springback report.png

Check.jpg NEW: Springback-Compensated LRA Grids

We've added new grids of LRA data:

Both VTube-STEP and VTube-LASER now have Springback-Compensated grids in the Tube data, Master Tube data, and the Measured Tube data menus.

Also, the new grids have popup menus that allow you to copy any part of the grid.

Vtube v2.2 springback grid popupmenu.png

VTube uses the FIXED and PROPORTIONAL springback variables in the Part Setup menu to calculate the springback compensated values in these grids.

If the proportional or fixed values are NON-ZERO, then you will see compensated values in these new grids.

Vtube-step v2.2 springback compensated grid.png

Check.jpg NEW: Multi-Elongation Percentage Compensation Setup

VTube-STEP now allows each bend to have a unique tube elongation percentage - which is used to calculate correct CUT LENGTHS and UNBENDING LENGTHS

Use the popup menus in either the PART SETUP or the XYZ grids to get to the setup window.

Vtube v2.2 XYZpopup multielongationsetup.png

A new checkbox is added at the bottom of Part Setup to allow this feature to be activated.

Vtube v2.2 partsetup multielongationsetup switch.png

If the checkbox is unchecked, then the single Tube Elongation % value is used to calculate elongation for all bends.

Vtube v2.2 multielongation setup window.png

Check.jpg ENHANCEMENT: Springback Compensation Calculation in the Outgoing Bender Data Is Now Optional

This feature adds springback compensation into the outgoing LRA data. In previous versions it was not optional.

For some benders (for example, the Eaton Leonard Lightspeed) this addition is NOT recommended because this causes the springback to be added by both VTube and the bender. This doubles the compensation - which is incorrect.

If you're not sure if you should use this option, then test how your bender uses the springback compensation values by entering non-zero Springback values in VTube's Part Setup menu, then send data with this feature activated. If the bend values display with the overbend doubled, then you know that the control handles the springback compensation automatically.

Vtube-step v2.3 benderoutput svnetwork springbackoption.png

Check.jpg ENHANCEMENT: Keep the Previous Custom Default Setup During Upgrades

If you've made changes to your default settings, you will want to skip installing a new set of configuration files. This version allows you to skip the installation of new configuration files with new choices in the installation file.

In addition to updating the main program files, you can now also control installation of:

  • Initial Configuration Files
  • Sample Files
  • Language Files
  • Report Templates



For example, if you changed the default setup in any way, then you should skip the installation of initial configuration files. VTube can run fine with older configurations.

Vtube-step v2.3 installation options.png

Other