Difference between revisions of "VTube Communication with AMOB"

From ATTWiki
Jump to: navigation, search
(At the AMOB Bender Data Export Window)
(Other Pages)
 
(24 intermediate revisions by one user not shown)
Line 32: Line 32:
 
</table>
 
</table>
  
==Communications Setup at the SOCO Bender==
+
==Communications Setup at the AMOB Bender==
 
<table>
 
<table>
 
<tr valign=top>
 
<tr valign=top>
Line 40: Line 40:
 
* Setup a shared network location either in the AMOB windows control or in a network path on your network.<br><br>
 
* Setup a shared network location either in the AMOB windows control or in a network path on your network.<br><br>
 
* If you share a folder on the AMOB control, then create a user with a username and password that can be used to login to the computer from the VTube-LASER computer.<br><br>
 
* If you share a folder on the AMOB control, then create a user with a username and password that can be used to login to the computer from the VTube-LASER computer.<br><br>
* To import VTL file data that VTube has created, enter the Program Machine Configuration menu. The FARO (or it may be "VTube") button will import transfer files that VTube creates.<br><br>
 
  
 
</td>
 
</td>
Line 65: Line 64:
 
</table>
 
</table>
  
===Setup the Benderlink Network Grid for the SOCO Bender===
+
===Setup the Benderlink Network Grid for the AMOB Bender===
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
Line 131: Line 130:
 
<br><br>
 
<br><br>
  
==How to SEND MASTER XYZ Data to the SOCO Control from VTube-LASER==
+
==How to SEND CORRECTION Data to the AMOB Control from VTube-LASER==
 +
 
 +
===After Bending the Tube===
 +
Bend a tube then measure it with VTube-LASER.<br><br>
 +
 
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
  
You can also send the new XYZ Centerline data from the VTube-LASER BENDER SETUP menu to the SOCO bender using the VTube Bender Output menu.<br><br>
+
===Measure the tube with VTube-LASER===
 
+
Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.
===Enter the XYZ Screen At the SOCO Control===
+
<br><br>
At the SOCO control, enter the XYZ Screen. With the XYZ Screen open, the SOCO control will understand that it must extract the MASTER XYZ data in the incoming data and import that into the SOCO NVS software.<br><br>
+
In the VTube-LASER screen shot, you see the actual result of the first tube not qualifying in shape. The red cells in the tangent point grid on the lower left show that the measured tube centerline is out-of-tolerance.
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:socoXYZscreen.png|600px]]
+
[[image:vtube-laser_v2.7_soco_part_measure.png|600px]]<br><br>
 +
[[image:vtube-laser_v2.7_soco_out_of_tolerance.png|600px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
 +
 +
  
 
<table cellpadding=10>
 
<table cellpadding=10>
Line 151: Line 157:
 
<td width=300>
 
<td width=300>
  
===Enter the BENDER SETUP menu in VTube-LASER===
+
===Correct the AMOB with VTube-LASER - Enter BENDER SETUP===
 
Follow these steps in the VTube-LASER:
 
Follow these steps in the VTube-LASER:
  
Line 165: Line 171:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
STEP 1 - Set the correct bender number at the top of the window. As of version 2.7, the SOCO SVNet option is available - which means you should see a SOCO bender at the top left corner of the screen.
 
  
 +
===INITIAL Setup of Bender Setup Window===
 +
The first time in this window for a new part will require these steps before you can correct the AMOB bender.<br><br>
  
STEP 2 - On the right click on "Setup the Bender".
+
STEP 1 - Set the correct bender number at the top of the window. The AMOB bender should display if you have already setup the bender protocol in the Benderlink grid.
  
  
STEP 3 - Click on AUTO SEND
+
STEP 2 - Click on the "Setup This Window" button.
<br><br>
+
The SOCO will receive new data and ask if it should be imported with a dialog.  Press YES to import the data.
+
</td>
+
<td width=400>
+
[[image:vtube-laser_v2.7_send_master_to_soco.png|600px]]
+
</td>
+
</tr>
+
</table>
+
  
  
<br><br>
+
STEP 3 - Click on the "Copy Master LRA to Setup LRA" button.
 
+
==How to SEND CORRECTION Data to the SOCO Control from VTube-LASER==
+
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
  
===At the SOCO Control===
 
At the SOCO control, setup and bend the first tube through the YBC and then Compile Execution screen.<br><br>
 
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:soco_compile_execution_screen.png|600px]]
+
[[image:VTL Bender Setup AMOB Bender New Setup.png|600px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
 +
  
 
<table cellpadding=10>
 
<table cellpadding=10>
Line 202: Line 195:
 
<td width=300>
 
<td width=300>
  
===After Bending the Tube===
+
===Check the BLUE COLUMN Data===
After the bending cycle is complete, remove the tube from the dies. Leave the bender in AUTO mode.<br><br>
+
The LRA blue column data is now filled with the MASTER LRA data.
 +
 
 +
This data MUST match the X axis, Y axis, Z axis bender data at the bender - or the corrections will be incorrect.  
 +
<br><br>
 +
 
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:soco_remove_part_from_bender.png|600px]]
+
[[image:VTL Bender Setup AMOB After Master Data Import.png|600px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 216: Line 213:
 
<td width=300>
 
<td width=300>
  
===Measure the tube with VTube-LASER===
+
===Send the Corrections to the AMOB VTL File===
Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.
+
Save the Correction data to the file for the AMOB to import.
 
<br><br>
 
<br><br>
In the VTube-LASER screen shot, you see the actual result of the first tube not qualifying in shape. The red cells in the tangent point grid on the lower left show that the measured tube centerline is out-of-tolerance.
+
STEP 1 - Click on Bidirectional Communication<br><br>
 +
STEP 2 - Click on AUTO SEND.<br><br>
 +
STEP 3 - Save the new VTL file to the network location.
 +
 
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:vtube-laser_v2.7_soco_part_measure.png|600px]]<br><br>
+
[[image:VTL Bender Setup AMOB Correction.png|600px]]<br><br>
[[image:vtube-laser_v2.7_soco_out_of_tolerance.png|600px]]<br><br>
+
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 229: Line 228:
  
  
 +
 +
<br><br>
  
 
<table cellpadding=10>
 
<table cellpadding=10>
Line 234: Line 235:
 
<td width=300>
 
<td width=300>
  
===Correct the SOCO with VTube-LASER - Enter BENDER SETUP===
+
===Import the Correction Data at the AMOB Control===
Follow these steps in the VTube-LASER:
+
Save the Correction data to the file for the AMOB to import.
 +
<br><br>
 +
STEP 1 - Enter the Program Machine Configuration menu. <br><br>
 +
STEP 2 - Press the FARO (or it may be "VTube") button<br><br>
 +
STEP 3 - Open the VTL file.<br><br>
  
Press the "BENDER SETUP button in the Navigation Pane.
 
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:vtube-laser_2.7_bendersetup_button_navigationpane.png|400px]]<br><br>
+
[[image:amob_program_machine_configuration_press_FARO.png|500px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 249: Line 253:
 
<td width=300>
 
<td width=300>
  
===RECALL SOCO YBC data and then SEND CORRECTIONS===
+
===AMOB Control Bender Data Updated===
STEP 1 - Set the correct bender number at the top of the window. As of version 2.7, the SOCO SVNet option is available - which means you should see a SOCO bender at the top left corner of the screen.
+
The bender data will be updated with the new values.<br><br>
 +
Bend the corrected part.
  
 
STEP 2 - If the Part Number is empty, then press the Copy the Master Part Setup values.
 
 
 
STEP 3 - Click on RECALL. This will update the BLUE columns in the Bender Setup.
 
 
 
STEP 4 - You can manually change the ADJUSTMENT values before sending corrections. In this case, we set the first and last Length adjustment to zero in order to keep the start position of the carriage in the same place.
 
 
 
STEP 5 - Click on AUTO SEND. This will send the ORANGE columns to the SOCO bender.
 
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:vtube-laser_v2.7_soco_send_correction.png|600px]]
+
[[image:AMOB bender data screen.png|500px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 271: Line 265:
  
  
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
  
===At the SOCO Bender - Press GO!===
 
Press GO!  The SOCO will compile the changes.
 
  
You will see a progress bar after you press GO!
+
==Synchronizing the VTube-LASER and AMOB Data Before Corrections==
<br><br>
+
[[image:soco_press_go_compile_execution_progressbar.png|300px]]
+
</td>
+
<td width=400>
+
[[image:soco_press_go_compile_execution.png|600px]]
+
</td>
+
</tr>
+
</table>
+
  
 
<table cellpadding=10>
 
<table cellpadding=10>
Line 292: Line 273:
 
<td width=300>
 
<td width=300>
  
The "Auto Compensation Completed" message will appear in the lower right corner.
+
It is critical to be sure the blue columns contain the same data that the AMOB X Axis, Y Axis, Z axis values have before correction is applied.<br><br>
  
Bend the corrected part now.
+
To make the data the value the same for the next correction, you can press the bottom button in the Bidirectional Communications menu on the right. Be sure you do this BEFORE you measure the next corrected part.<br><br>
</td>
+
<td width=400>
+
[[image:soco_auto_compensation_completed.png|600px]]
+
</td>
+
</tr>
+
</table>
+
  
<table cellpadding=10>
+
The reason for this step is because the AMOB does not allow VTube to RECALL data in order to update the BLUE columns for the next correction. So this process must be performed manually.<br><br>
<tr valign=top>
+
<td width=300>
+
  
===Measure at the VTube-LASER Computer===
+
The data in the blue and the orange columns will now be identical. You can exit this window and measure the next corrected part.
Measure and align the tube again to determine if it qualifies by falling within the envelope tolerance for the tube shape.
+
<br><br>
+
This screen shot shows an actual resulting change after the correction.
+
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:vtube-laser_v2.7_soco_part_qualifies.png|600px]]<br><br>
+
[[image:Combine Adjusted back into LRA then CLEAR Adjusted.png]]<br><br>
 +
[[image:Adjusted data combined into blue columns.png|600px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
 
 
 
<br><br>
 
  
 
==Other Pages==
 
==Other Pages==
 
* See [[VTube-LASER]]
 
* See [[VTube-LASER]]
 
* See [[VTube-STEP]]
 
* See [[VTube-STEP]]
* See [[SOCO]] for information on the SOCO benders
 
* See [http://www.advancedtubular.wiki/index.php/VTube-LASER_Videos#Video_62:_Setup_and_Correct_SOCO_Benders_with_VTube-LASER_Communications Video 62 - SOCO Communications Video] to see an actual corrections loop with a SOCO bender.
 

Latest revision as of 17:55, 24 January 2017

Amob bender and logo.png

About this Page

This page describes the setup and use of the VTube to AMOB communications.

Vtube v2.5 image to amob.png


The Basics of How It Works

  • VTube sends data to the AMOB by exporting a ".VTL" file that the AMOB can read. Communications can be setup through a standard Windows network connection, or you can use a thumb drive.

  • The communication is unidirectional toward the bender. It is not possible to RECALL data from the AMOB using this file. The AMOB control only reads this file data.

  • The data that is included in the VTL file that the AMOB can read is the BENDER data (X axis, Y Axis, C Axis). The data also includes the diameter, wall thickness, and cut length.

Communications Setup at the AMOB Bender

  • Connect the AMOB bender to the network using a standard Ethernet cable.

  • Setup a shared network location either in the AMOB windows control or in a network path on your network.

  • If you share a folder on the AMOB control, then create a user with a username and password that can be used to login to the computer from the VTube-LASER computer.

Amob program machine configuration press FARO.png

Setup Benderlink at VTube-STEP or VTube-LASER

Entering Benderlink Setup

  1. Enter the VTube System Options menu.

  2. Enter the Measure 2 tab menu.

  3. Enter the Setup Benderlink Network menu.

VTube System Options Benderlink Network Button.png

Setup the Benderlink Network Grid for the AMOB Bender

  1. Choose an unused row in the grid for a new AMOB bender setup. (Click on the image at the right to see a zoomed image.)

  2. Assign a bender name that will help operators identify what this bender is. This text will be displayed at the top of the Bender Setup menu.

  3. Set the protocol to AMOB VTL Data.

  4. Enter the path to the shared drive or folder in the NetPath field. Use the same location as the AMOB setup. VTube accepts UNC names as well as regular paths with drive letters.

  5. Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)

  6. Press Close to save the settings. VTube will save these values to a persistent configuration file that will not change unless you change them in this grid.

VTube Benderlink Setup for AMOB VTL.png

How to SEND MASTER BENDER Data to the AMOB Control from VTube-STEP

You can import data into VTube-STEP then send the bender data calculated to the AMOB bender using the VTube Input/Export menu.


At the VTube-STEP Main Screen

Move to the VTube-STEP computer and follow these steps to transfer the bender data to the AMOB.

  1. Press the Import/Export button in the navigation pane.
  2. Find and press the AMOB VTL Data button in the Export section.

Vtube-step v2.7 AMOB Export Button.png

At the AMOB Bender Data Export Window (inside VTube-STEP)

Press the Export button to save a VTL file on the network at the shared path for the AMOB bender.

Vtube-step v2.7 AMOB Export Window.png




How to SEND CORRECTION Data to the AMOB Control from VTube-LASER

After Bending the Tube

Bend a tube then measure it with VTube-LASER.

Measure the tube with VTube-LASER

Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.

In the VTube-LASER screen shot, you see the actual result of the first tube not qualifying in shape. The red cells in the tangent point grid on the lower left show that the measured tube centerline is out-of-tolerance.

Vtube-laser v2.7 soco part measure.png

Vtube-laser v2.7 soco out of tolerance.png


Correct the AMOB with VTube-LASER - Enter BENDER SETUP

Follow these steps in the VTube-LASER:

Press the "BENDER SETUP button in the Navigation Pane.

Vtube-laser 2.7 bendersetup button navigationpane.png

INITIAL Setup of Bender Setup Window

The first time in this window for a new part will require these steps before you can correct the AMOB bender.

STEP 1 - Set the correct bender number at the top of the window. The AMOB bender should display if you have already setup the bender protocol in the Benderlink grid.


STEP 2 - Click on the "Setup This Window" button.


STEP 3 - Click on the "Copy Master LRA to Setup LRA" button.

VTL Bender Setup AMOB Bender New Setup.png


Check the BLUE COLUMN Data

The LRA blue column data is now filled with the MASTER LRA data.

This data MUST match the X axis, Y axis, Z axis bender data at the bender - or the corrections will be incorrect.

VTL Bender Setup AMOB After Master Data Import.png


Send the Corrections to the AMOB VTL File

Save the Correction data to the file for the AMOB to import.

STEP 1 - Click on Bidirectional Communication

STEP 2 - Click on AUTO SEND.

STEP 3 - Save the new VTL file to the network location.

VTL Bender Setup AMOB Correction.png




Import the Correction Data at the AMOB Control

Save the Correction data to the file for the AMOB to import.

STEP 1 - Enter the Program Machine Configuration menu.

STEP 2 - Press the FARO (or it may be "VTube") button

STEP 3 - Open the VTL file.

Amob program machine configuration press FARO.png

AMOB Control Bender Data Updated

The bender data will be updated with the new values.

Bend the corrected part.

AMOB bender data screen.png



Synchronizing the VTube-LASER and AMOB Data Before Corrections

It is critical to be sure the blue columns contain the same data that the AMOB X Axis, Y Axis, Z axis values have before correction is applied.

To make the data the value the same for the next correction, you can press the bottom button in the Bidirectional Communications menu on the right. Be sure you do this BEFORE you measure the next corrected part.

The reason for this step is because the AMOB does not allow VTube to RECALL data in order to update the BLUE columns for the next correction. So this process must be performed manually.

The data in the blue and the orange columns will now be identical. You can exit this window and measure the next corrected part.

Combine Adjusted back into LRA then CLEAR Adjusted.png

Adjusted data combined into blue columns.png

Other Pages