− | =HERBER MES Data Protocol= | + | =HERBER MES Data Protocol Information= |
+ | These are important facts to know about this protocol. | ||
+ | |||
<table width=900> | <table width=900> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | * The HERBER MES protocol is network protocol. | + | * The HERBER MES protocol is network protocol. It can be setup over a network or for use with a thumb drive.<br><br> |
− | * The protocol is unidirectional. Data only flows from VTube-LASER to the HERBER. | + | * The HERBER MES protocol is only for correction of the bender - not NEW PART setup. For new part setup, see the HERBER SOL protocol.<br><br> |
+ | * The protocol is unidirectional. Data only flows from VTube-LASER to the HERBER.<br><br> | ||
+ | * Th reason it is unidirectional is because the HERBER control only needs to receive the bender ADJUSTMENT (or Correction) values alone to correct the bender.<br><br> | ||
+ | * Therefore, the RECALL button in the VTube-LASER Bender Setup window is always disabled with the HERBER MES protocol.<br><br> | ||
* The HERBER MES protocol requires that you have nominal (master) data programmed in before you send corrections. VTube-LASER will stop the correction if it senses the wrong number of bends in the master data. | * The HERBER MES protocol requires that you have nominal (master) data programmed in before you send corrections. VTube-LASER will stop the correction if it senses the wrong number of bends in the master data. | ||
+ | |||
</td> | </td> | ||
Line 48: | Line 55: | ||
=BENDERLINK SETUP STEPS FOR VTUBE-LASER= | =BENDERLINK SETUP STEPS FOR VTUBE-LASER= | ||
− | |||
===STEP 1: Enter the SYSTEM OPTIONS Menu in VTube=== | ===STEP 1: Enter the SYSTEM OPTIONS Menu in VTube=== | ||
− | <table width= | + | <table width=1000> |
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | |||
#Click on Systems Options in the toolbar at the top of the screen.<br><br> | #Click on Systems Options in the toolbar at the top of the screen.<br><br> | ||
#Enter the Measure 2 tab menu.<br><br> | #Enter the Measure 2 tab menu.<br><br> | ||
Line 62: | Line 67: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image: | + | [[image:vtl_v2.9.10_herberbenderlinksetup_enterbenderlinkgrid.png|600px]] |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | <br><br><br> | ||
===STEP 2: Setup the Benderlink Network Grid for HERBER MES Protocol=== | ===STEP 2: Setup the Benderlink Network Grid for HERBER MES Protocol=== | ||
− | <table cellpadding=10 width= | + | <table cellpadding=10 width=1100> |
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | #Choose an unused row in the grid for a new | + | #Choose an unused row in the grid for a new HERBER bender setup.<br><br> |
#Assign a bender name that will help operators identify which bender this is. This text will be displayed at the top of the Bender Setup menu.<br><br> | #Assign a bender name that will help operators identify which bender this is. This text will be displayed at the top of the Bender Setup menu.<br><br> | ||
− | #Assign the HERBER MES protocol.<br><br> | + | #Assign the HERBER MES+SOL protocol.<br><br> |
#Enter the path to the shared drive or folder in the NetPath field. This path should point to the HERBER folder that will receive MES files from VTube. (The value shown on the screen is only an example.)<br><br> | #Enter the path to the shared drive or folder in the NetPath field. This path should point to the HERBER folder that will receive MES files from VTube. (The value shown on the screen is only an example.)<br><br> | ||
#Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)<br><br> | #Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)<br><br> | ||
Line 81: | Line 87: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:vtl_benderlink_herber.png| | + | [[image:vtl_benderlink_herber.png|700px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 90: | Line 96: | ||
<br><br> | <br><br> | ||
− | + | =[[image:vtube-laser_logo_1.96.png|200px]] How to SEND CORRECTION Data to the HERBER Control from VTube-LASER= | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | =[[image:vtube-laser_logo_1.96.png|200px]] How to SEND CORRECTION Data to the | + | |
===STEP 1 - Bend the Tube=== | ===STEP 1 - Bend the Tube=== | ||
Line 239: | Line 102: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | Bend the tube in the | + | Bend the tube in the HERBER bender.<br><br> |
<td> | <td> | ||
− | [[image: | + | [[image:HERBER Control Station.png|200px]] [[image:herber bender large tube bending.png|400px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 271: | Line 134: | ||
<td> | <td> | ||
[[image:VTube-LASER UNISON Click on Bender Setup.png|400px]]<br><br> | [[image:VTube-LASER UNISON Click on Bender Setup.png|400px]]<br><br> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
</td> | </td> | ||
</tr> | </tr> | ||
Line 292: | Line 144: | ||
Set the correct bender number at the top of the window.<br><br> | Set the correct bender number at the top of the window.<br><br> | ||
You can select up to 100 different benders.<br><br> | You can select up to 100 different benders.<br><br> | ||
− | The Bender Protocol should say " | + | The Bender Protocol should say "HERBER MES". (This assumes that you have already configured VTube's Benderlink in the Systems Options as described in the previous section.) |
</td> | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:vtl_v2.9.10_bendersetup_choosebender_herber.png|400px]] |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ===STEP 5 - | + | ===STEP 5 - COPY the Data from VTube-LASER's Main Memory=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | If this is the first correction, then the Bender Setup screen may show no data. If this is the case, then it is necessary to update the Bender Setup screen from VTube-LASER's main memory like this:<br><br> | |
− | + | * Press "Setup this Window". | |
− | + | * Press "Copy Master LRA to Setup LRA". | |
</td> | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:vtl_v2.9.10_herber_copy_master_lra_to_setup_lra.png|400px]]<br><br> |
− | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
===STEP 6 - OPTIONAL STEP - You Can Manually Change the ADJUSTMENT Values=== | ===STEP 6 - OPTIONAL STEP - You Can Manually Change the ADJUSTMENT Values=== | ||
Line 335: | Line 174: | ||
If you want to, it is even possible to invert the rotation direction to keep the tube from hitting the bender during rotations. | If you want to, it is even possible to invert the rotation direction to keep the tube from hitting the bender during rotations. | ||
<td> | <td> | ||
− | [[image: | + | [[image:vtl_v2.9.10 HERBER Manually Adjust Correction Values.png|400px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ===STEP 7 - Send | + | ===STEP 7 - Send Corrections to the HERBER=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | Press "Auto SEND Bender CORRECTIONS". VTube-LASER will let you select a path, then save a MES file to that path. | |
− | + | ||
<td> | <td> | ||
− | [[image: | + | [[image:vtl_v2.9.10_herber_send_corrections.png|400px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 359: | Line 197: | ||
You can allow this window to close on its own in a few seconds, or press the close button to close it immediately. | You can allow this window to close on its own in a few seconds, or press the close button to close it immediately. | ||
<td> | <td> | ||
− | [[image: | + | [[image:vtl_v2.9.10 HERBER Send Adjusted Complete.png|400px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ===STEP 9 - IMPORT the Correction Data at the | + | ===STEP 9 - IMPORT the Correction Data at the HERBER Control=== |
Line 370: | Line 208: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | Move to the | + | Move to the HERBER control and follow these steps:<br><br> |
− | + | * Click on “Read measurement from machine” in the Communications menu.<br><br> | |
− | + | * Select your measuring system (VTube). | |
− | + | ||
− | + | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:HERBERScreen1.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
+ | |||
+ | <tr valign=top> | ||
+ | <td width=500> | ||
+ | * Select the .MES file VTube-LASER just created. When you click OK, the HERBER software will ask if you want to delete the MES file after importing.<br><br> | ||
+ | * To apply all corrections from the mes file, click on “Save all measurements” and continue bending. You are not required to stop the machine to do this. The HERBER cell allows for correction in an automated production cell in realtime. The corrections will be applied for the next part bent. | ||
+ | |||
+ | </td> | ||
+ | <td> | ||
+ | [[image:HERBERScreen2.png|500px]]<br> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr valign=top> | ||
+ | <td width=500> | ||
+ | * It is also possible to delete or save individual correction values by marking a bend and opening the measure tab. | ||
+ | |||
+ | </td> | ||
+ | <td> | ||
+ | [[image:HERBERScreen3.png|500px]]<br> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | |||
</table> | </table> | ||
Line 388: | Line 248: | ||
Bend the corrected tube starting in Step 1, then measure it again (Step 2) and follow the rest of the steps until the part is within tolerance. | Bend the corrected tube starting in Step 1, then measure it again (Step 2) and follow the rest of the steps until the part is within tolerance. | ||
<td> | <td> | ||
− | [[image: | + | [[image:HERBER Control Station.png|200px]] [[image:herber bender large tube bending.png|400px]] |
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 20:38, 5 July 2018
This page describes the use of the VTube-LASER to HERBER bender corrections using the HERBER MES protocol. |
Back to VTube-LASER
Network Protocol
The protocol used is called "HERBER MES" and runs through a standard network connection - wired or wireless. |
HERBER MES Data Protocol Information
These are important facts to know about this protocol.
|
BENDERLINK SETUP STEPS FOR VTUBE-LASER
STEP 1: Enter the SYSTEM OPTIONS Menu in VTube
|
STEP 2: Setup the Benderlink Network Grid for HERBER MES Protocol
|
How to SEND CORRECTION Data to the HERBER Control from VTube-LASER
STEP 1 - Bend the Tube
Bend the tube in the HERBER bender. |
STEP 2 - Measure the tube with VTube-LASER
Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape. |
STEP 3 - Enter BENDER SETUP
Click on the BENDER SETUP button in the Navigation Pane. |
STEP 4 - Choose the BENDER NUMBER
Set the correct bender number at the top of the window. |
STEP 5 - COPY the Data from VTube-LASER's Main Memory
If this is the first correction, then the Bender Setup screen may show no data. If this is the case, then it is necessary to update the Bender Setup screen from VTube-LASER's main memory like this:
|
STEP 6 - OPTIONAL STEP - You Can Manually Change the ADJUSTMENT Values
You can manually change the ADJUSTMENT values before sending corrections if you want to. Some users like to set the first and last Length adjustment to zero in order to keep the start position of the carriage in the same place - for when they have extra length on the ends. |
STEP 7 - Send Corrections to the HERBER
Press "Auto SEND Bender CORRECTIONS". VTube-LASER will let you select a path, then save a MES file to that path. |
STEP 8 - The SEND to BENDER Complete Window
A window should appear for a few seconds indicating that the Send to the Bender is complete. |
STEP 9 - IMPORT the Correction Data at the HERBER Control
Move to the HERBER control and follow these steps:
|
|
|
|
|
STEP 10 - REPEAT STEPS 1 THROUGH 9
Bend the corrected tube starting in Step 1, then measure it again (Step 2) and follow the rest of the steps until the part is within tolerance. |
Other Pages
- See VTube-LASER
- See VTube-STEP
- See UNISON for information on UNISON benders