Difference between revisions of "VTube-LASER Scan Score"
(→The Scan Score Protects Users from Poor Scans) |
(→The Scan Score and the Alignment Window) |
||
(3 intermediate revisions by one user not shown) | |||
Line 57: | Line 57: | ||
As the historical list of Cylinder Fit values grows, the scan score becomes more helpful.<br><br> | As the historical list of Cylinder Fit values grows, the scan score becomes more helpful.<br><br> | ||
If your overall score on the last measure is 75%, then it is reasonable to suspect that something is wrong with the last tube measure - and you should rescan the tube before accepting the measured data as certain.<br><br> | If your overall score on the last measure is 75%, then it is reasonable to suspect that something is wrong with the last tube measure - and you should rescan the tube before accepting the measured data as certain.<br><br> | ||
− | In the scan score example shown here, we deformed the last straight section of a two bend part with | + | In the scan score example shown here, we deformed the last straight section of a two bend part with metal tape in order to achieve this low score. The last straight fails the qualification in this measure. The low scan score is an indicator that the measure is poor and should not be accepted until you remeasure.<br><br> |
+ | [[image:scanscore_testpart_deformation.png|400px]] | ||
</td> | </td> | ||
<td> | <td> | ||
Line 72: | Line 73: | ||
<td width=400> | <td width=400> | ||
The Scan Score is always display in the alignment window like this.<br><br> | The Scan Score is always display in the alignment window like this.<br><br> | ||
− | The score is calculated before alignment begins, so if the score is low, then you can press the Stop button to remeasure. | + | The score is calculated before alignment begins, so if the score is low, then you can press the Stop button before the alignment is complete to remeasure.<br><br> |
+ | In this case, the score is very high because we forced the last measure to be very bad for this test. Historical measures that are bad will cause future measures to scan higher like this. | ||
</td> | </td> | ||
<td> | <td> |
Latest revision as of 19:07, 8 July 2020
VTube-LASER Scan Score
|
Contents |
What is the VTube-LASER SCAN SCORE?
We invented the SCAN SCORE system as a way for users to score the performance of the last scan based on all previously stored historical data. |
How the Scan Score is Calculated
All the Cylinder Fit values from each completed measure are stored in the VTube-LASER project file and then used to create scores for each attribute on each straight. |
The Scan Score Protects Users from Poor Scans
The Scan Score and the Alignment Window
The Scan Score is always display in the alignment window like this. |
See VTube-LASER Accumulating the Scan Score While Scanning
Click on the video image to see VTube-LASER scanning with the scan score display. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature