Difference between revisions of "Cable Spec 33"
From ATTWiki
(→Other Pages) |
|||
(One intermediate revision by one user not shown) | |||
Line 1: | Line 1: | ||
+ | __TOC__ | ||
+ | |||
+ | ==Cable in the Box== | ||
+ | |||
For use inside Benderlink Ethernet Modules with current loop electronics. | For use inside Benderlink Ethernet Modules with current loop electronics. | ||
<br><br> | <br><br> | ||
Line 8: | Line 12: | ||
<br> | <br> | ||
<br> | <br> | ||
− | Wiring schematic | + | ==Wiring schematic== |
[[image:cable_33_wire_scheme.jpg|600px]] | [[image:cable_33_wire_scheme.jpg|600px]] | ||
<br> | <br> | ||
Line 18: | Line 22: | ||
[[image:cb-el1_bendermode.jpg|800px]] | [[image:cb-el1_bendermode.jpg|800px]] | ||
− | ==Breakout Tester== | + | <br><br> |
+ | |||
+ | ==Breakout Tester for Cable 33== | ||
Use a breakout tester for continuity checks like this: | Use a breakout tester for continuity checks like this: |
Latest revision as of 16:51, 23 August 2022
Contents |
Cable in the Box
For use inside Benderlink Ethernet Modules with current loop electronics.
Use for simulating the PREMIER (Bender) side only.
Wiring schematic
CB-EL1 Board Setup For Use With Cable 33
In this configuration, it is necessary to use a version 2 CB-EL1 board with the jumpers set to "BND" to simulate the bender side of the connection. Use this setup for connecting a non Eaton Leonard bender to an Eaton Leonard Vector measuring center. You can also use this cable to replace the current loop board at a Premier bender.
The original CB-EL1 board (without jumpers) can only handle the Vector measuring center side connection. Do not use v1 in this configuration.
Breakout Tester for Cable 33
Use a breakout tester for continuity checks like this: