− | The HD blue | + | The FARO ScanArm HD blue laser scanner has significantly increased capabilities than earlier scanners. Because of that, it has different setup recommendations for the FARO Laser Line Probe Control window. These settings work very well in VTube-LASER specifically with the HD scanner.<br><br> |
'''VTube-LASER be connected to a FARO arm to perform these steps.''' | '''VTube-LASER be connected to a FARO arm to perform these steps.''' | ||
</td> | </td> |
Revision as of 03:12, 26 December 2015
|
Page Revision Date: December 24, 2015
Ideal Setup for the HD (Version 6) Blue Laser Scanner in VTube-LASER
The FARO ScanArm HD blue laser scanner has significantly increased capabilities than earlier scanners. Because of that, it has different setup recommendations for the FARO Laser Line Probe Control window. These settings work very well in VTube-LASER specifically with the HD scanner. |
STEP 1In VTube-LASER window click on Scanner Algorithm label above the viewport window. |
|
STEP 2Set the Scan Rate to 1/1.
Set the Scan Density to 1/16
|
|
STEP 3For most materials set the Algorithm to Automatic - Normal. |
|
STEP 4Uncheck the Reflection Filter option.
|
|
STEP 5Click on the OK button to exit the FARO Laser Line Probe window. |