Ideal Setup for the HD (Version 6) Blue Laser Scanner in VTube-LASER
The FARO ScanArm HD blue laser scanner has significantly increased capabilities compared to earlier FARO scanners. |
STEP 1In VTube-LASER window click on Scanner Algorithm label above the viewport window. |
|
STEP 2Set the Scan Rate to 1/1.
Set the Scan Density to 1/16
|
|
STEP 3For most materials set the Algorithm to Automatic - Normal. |
|
STEP 4Uncheck the Reflection Filter option.
|
|
STEP 5Click on the OK button to exit the FARO Laser Line Probe window. |