Difference between revisions of "VTube-STEP v2.8.3"
From ATTWiki
(Created page with "<table> <tr cellpadding=10> <td width=225> 300px ==Revision 2.8.3== * Back to VTube-STEP * Back to VTube-STEP Updates * See also VTube-...") |
|||
Line 18: | Line 18: | ||
<br><br> | <br><br> | ||
__TOC__ | __TOC__ | ||
+ | |||
+ | ==[[image:Check.jpg|25px]] ENHANCED: NUMALLIANCE BENDER OUTPUT HANDLES 180-DEGREE BENDS== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | === OUTPUTS 180-DEGREE BENDS === | ||
+ | * The NUMALLIANCE CSV export now compresses SPLIT BENDS into a single 180-degree bends during export to the NUMALLIANCE CSV.<br><br> | ||
+ | === OUTPUTS SPRINGBACK-COMPENSATED DATA === | ||
+ | * The NUMALLIANCE CSV export now includes springback-compenstation if you choose that option during export.<br><br> | ||
+ | <td> | ||
+ | [[image:vtube-step_v2.8.2_numalliance_split_bend.png|600px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]] ENHANCED: SUPRAVISION IMPORT HANDLES DATA WITH NO CENTERLINE XYZ POINTS== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | VTube requires XYZ coordinates for the parametric tube data.<br><br> | ||
+ | However, some Supravision files contain only bender data with no centerline XYZ data.<br><br> | ||
+ | VTube now detects this situation and automatically reverse-calculates to create a new set of XYZ data when necessary. | ||
+ | <td> | ||
+ | [[image:vtube-step_v2.8.3_SV Import Button.png]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]] ENHANCED: DOCS IMPORT SETS THE PART NUMBER to the INCOMING FILENAME== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | Previous versions of VTube would use the actual DOCS part number of "Part 1", "Part 2", etc., in the VTube Part Number.<br><br> | ||
+ | A customer that imports DOCS files into VTube requested that the VTube Part Number be set to the incoming filename.<br><br> | ||
+ | We made this change in this version. | ||
+ | <td> | ||
+ | [[image:Romer_docs_egrtube.jpg|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]] FIX: IMPORTED MODEL DELETION ISSUE RESOLVED== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | VTube would randomly delete the imported model after a parametric data build. This has been fixed. | ||
+ | <td> | ||
+ | [[image:vtube-step_v2.8.3_automotive tube with components.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> |
Revision as of 15:57, 25 May 2017
Revision 2.8.3
|
Contents |
ENHANCED: NUMALLIANCE BENDER OUTPUT HANDLES 180-DEGREE BENDS
OUTPUTS 180-DEGREE BENDS
OUTPUTS SPRINGBACK-COMPENSATED DATA
|
ENHANCED: SUPRAVISION IMPORT HANDLES DATA WITH NO CENTERLINE XYZ POINTS
VTube requires XYZ coordinates for the parametric tube data. |
ENHANCED: DOCS IMPORT SETS THE PART NUMBER to the INCOMING FILENAME
Previous versions of VTube would use the actual DOCS part number of "Part 1", "Part 2", etc., in the VTube Part Number. |
FIX: IMPORTED MODEL DELETION ISSUE RESOLVED
VTube would randomly delete the imported model after a parametric data build. This has been fixed. |