Difference between revisions of "VTube-LASER v2.9.9"
(→25pxNEW - SCP Feature (Stripe Cut Plane) - Eliminates LASER Stripe Data That Is Too Far From the Probe) |
(→25pxNEW - SCP Feature (Stripe Cut Plane) - Eliminates LASER Stripe Data That Is Too Far From the Probe) |
||
Line 33: | Line 33: | ||
The new STRIPE CUT PLANE feature is designed to eliminate entire laser stripes of data that are too far from the probe. It is included in the CUT PLANE CONTROL Window.<br><br> | The new STRIPE CUT PLANE feature is designed to eliminate entire laser stripes of data that are too far from the probe. It is included in the CUT PLANE CONTROL Window.<br><br> | ||
This is helpful for smaller parts because the scanners have an active depth range that allows them to pick up stripes that are within a 127mm (5 inch) inch range top to bottom.<br><br> | This is helpful for smaller parts because the scanners have an active depth range that allows them to pick up stripes that are within a 127mm (5 inch) inch range top to bottom.<br><br> | ||
− | + | The goal of the SCP feature is to ensure that the scanner does not accidentally catch any object in a stripe that is far away from the first diameter relative to the probe. | |
<br><br> | <br><br> |
Revision as of 23:01, 8 June 2018
Revision 2.9.9Release Date: June 11, 2018
|
NEW - SCP Feature (Stripe Cut Plane) - Eliminates LASER Stripe Data That Is Too Far From the Probe
The new STRIPE CUT PLANE feature is designed to eliminate entire laser stripes of data that are too far from the probe. It is included in the CUT PLANE CONTROL Window.
SCP works with the DCP feature to ensure that no stray laser stripe data is used in a scan like this:
|
FIX- MTA (Measured Tube Averaging)
We discovered that the MTA feature would record all the tubes and build he average in Tube Data Storage, but would not copy it into main memory. |
NEW - SHOW "SPLIT BENDS PRESENT" in WARNING HEADER
When Split Bends are present (180-degree bends or greater), then a new message displays in the header: "Split bends present", and turns the header yellow. |
NEW - End-A and End-B OFFSET VALUES IN REPORTS
The offset values are the same as the old Supravision "tangent" end points in the Critical Reports section of the Inspection Data report.
|
ENHANCED - SPLIT BEND FEATURE
|
ENHANCED - FLOATING TOOL WINDOWS STAY ON TOP
The floating windows have some enhancements in this version that ensures that they stay on top of parent windows. |
|
OTHER CHANGES
|
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature