Difference between revisions of "VTube-LASER v1.6"
From ATTWiki
Line 24: | Line 24: | ||
The image at the right shows a side view of the result of an end-scan of a tube. The LLP (laser line probe) is positioned above the tube at the top of this image and is pointed downward in the direction of the left black arrow. The laser is moving downward along its path from the probe. It is then reflected back to the receiver of the scanner in the path of the right arrow. <br><br> | The image at the right shows a side view of the result of an end-scan of a tube. The LLP (laser line probe) is positioned above the tube at the top of this image and is pointed downward in the direction of the left black arrow. The laser is moving downward along its path from the probe. It is then reflected back to the receiver of the scanner in the path of the right arrow. <br><br> | ||
Most of the points fall on the surface of the outside of the tube, inside the tube, or wall of the tube. However, there is also an outlier point present (enclosed in the red lines at the top). It cannot possibly part of the diameter. (These points were formed from a higher-than-normal reflective points on the inside of the diameter. <br><br> | Most of the points fall on the surface of the outside of the tube, inside the tube, or wall of the tube. However, there is also an outlier point present (enclosed in the red lines at the top). It cannot possibly part of the diameter. (These points were formed from a higher-than-normal reflective points on the inside of the diameter. <br><br> | ||
− | |||
− | |||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:vtube-laser_endscan_outlier_detection.jpg|300px]] | + | [[image:vtube-laser_endscan_outlier_detection.jpg|300px]]<br><br> |
+ | The outlier point is detected and then removed from the list of possibilities automatically because it is not close enough to the diameter or wall of the diameter.<br><br> | ||
+ | This ensures repeatability of the end-scan process. | ||
+ | |||
</td> | </td> | ||
</tr> | </tr> |
Revision as of 21:29, 21 February 2011
Revision 1.6Back to VTube-LASER |
NEW: End Scan Outlier Detection
REPAIR: Mix ball probe and laser measurement
Using ball probe measurements on the end scans and and laser measurements in the cylinder straights now offsets the ball radius point properly in every case. |
ENHANCEMENT- Part Name is Used as Filename When Part Name Changes
In previous versions, the part name was used as the filename only if the previous filename was empty.
|
ENHANCED- Linear Units Now Set By Single Large Button
In previous versions, the linear units radio buttons were not reliable in setting the proper state.
|
REPAIR- Laser Active Initialization
In previous versions, VTube required the operator to enter Measure Setup at least one time when coming into Laser Mode in order to setup the Laser active mode. |
Other Changes
|
Changes to VTube-STEP
|
Issues with this version fixed in next version
|
Other Pages
- Back to VTube-LASER