Difference between revisions of "VTube-LASER v1.75"
Line 52: | Line 52: | ||
VTube now includes a new FILE tab menu in the MASTER XYZ data menu. This file tab menu allows operators to save data to save the MASTER data to a BENDER file. The output can support any file-type that is currently supported in VTube. | VTube now includes a new FILE tab menu in the MASTER XYZ data menu. This file tab menu allows operators to save data to save the MASTER data to a BENDER file. The output can support any file-type that is currently supported in VTube. | ||
<br><br> | <br><br> | ||
+ | This includes: | ||
+ | * $$$ Supravision Files (Supravision legacy) | ||
+ | * SV Supravision Files (DOCS) | ||
+ | * S2B Supravision Files (For transferring using the Supravision Network protocol.) | ||
+ | * CSM bender files | ||
+ | * Winton bender files | ||
</td> | </td> | ||
<td width=300> | <td width=300> |
Revision as of 23:30, 28 January 2012
Revision 1.75Back to VTube-LASER |
CRITICAL ENHANCEMENT: Split Bend Logic and Display
After extensive Gage R&R tests, the Split Bend logic is completely rewritten and is more accurate and robust than the original logic.
|
ENHANCED: Scanner Setup Enhancements
|
NEW: Save MASTER BENDER Data from the MASTER XYZ Data Menu
VTube now includes a new FILE tab menu in the MASTER XYZ data menu. This file tab menu allows operators to save data to save the MASTER data to a BENDER file. The output can support any file-type that is currently supported in VTube.
|
NEW: Pull Arm From Resting Message
If the arm uses firmware version 702 or less, then it will display special messages when it is about to update the Scanner Control. Follow these instructions if you change the Scanner Control setup from project to project. The reason for this new step is that the Scanner Control will not update any integer values to or from VTube-LASER if the LASER is not able to be switched on during setup. |
NEW: Separate Cylinder Fit Tolerances for LONG and SHORT Cylinders
VTube now has a second set of tolerances for shorter straights. This allows for looser tolerances on shorter straights without producing an error message.
|
NEW: Cylinder Fit Radius Deviation Check
VTube now checks to be sure that all point clouds used in the diameter calculation all fall within a reasonable tolerance for distance from the calculated centerline.
|
Other Changes
A new tolerance is added for surface point diameter check. |
The current arm firmware is now read and used by VTube to determine how to handle the arm during Scanner Control changes. |
For high-precision end scans, new end-scan techniques are recommended in the VTube-LASER manual. |
Other Pages
- Back to VTube-LASER