CNC Bender v14.9-r10

From ATTWiki
Revision as of 14:18, 12 March 2016 by Mcone (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

v14.9-r10 - March 10, 2015

Cncbender v14 logo.png


Check.jpg ENHANCEMENT: Cross Slide Check

In previous versions of CNC Bender, the internal logic would not allow the manual page jog close of either PRESSURE die or CLAMP die if the Cross Slide INPUT for AWAY from die (or in the home position) was active.

This has been changed so that CNC Bender now only examines the Cross Slide INPUT for ADVANCED or IN the die active.

This allows for locking the carriage cross slide for little or no movement - with both prox switched active at the same time - and still close the dies.

Check.jpg ENHANCEMENT: SUPRAVISION Communications Enhancement

Previous versions of CNC Bender would send Supravision data with XYZ values even if the XYZ values had not been setup (and were all zeros).

This caused ROMER software products to refuse the incoming data and display an error.

This release of CNC Bender will automatically remove the XYZ data if they are all zeros. This satisfies the ROMER software rules.


Check.jpg FIX: Mandrel Lube for Positive Bend Direction

The mandrel lube would lube for both positive and negative bend motions. This has been fixed so that it is only lubing in the positive direction.


Check.jpg ENHANCED: Jog Halt

When a direct axis jog button is released, the motion will stop much faster than in previous versions.




Other Pages