DOCS

From ATTWiki
Revision as of 06:36, 21 December 2007 by Mcone (Talk | contribs)

Jump to: navigation, search
Docs screen1.jpg

DOCS is a software package that is sold by Romer. The word "DOCS" means Data Overlay Camera System. Read more about DOCS at these sites:





Contents

Screen Image

This is a screen image from our test license of DOCS software.

Romer docs egrtube.jpg


Comparing DOCS to Supravision

Supravision and DOCS are developed by Romer. Supravision is the older legacy program for tube measurement. This matrix offers a comparison between the two software packages:

DOCS Software

Supravision Software

Active - Continued development

Static - No more development

Allows for the measurement of tube data and non-tube data surrounding the tube - including brackets and other fabrications

Measures only tube shapes

Because it is more powerful, it is also more complex. Thus - this software takes longer to learn.

Supravision is very easy to learn.

Can use contact or non-contact measurement

Can only use non-contact measurement of tube shapes

Can measure multiple tubes in a single DOCS file

Can measure one tube per Supravision file

Romer charges a fee for every bender connected to DOCS.

There is no charge from ROMER for connection through Supravision.

Tube Shop Manager (TSM) is an optional feature in DOCS. You must purchase TSM if you want to measure and correct tubes in DOCS software.

Tube measurement is standard in Supravision (because that is all Supravision can do).



Our Recommendation

As of December, 2007, we have been given a license of DOCS software for evaluation and testing with our Benderlink software.

DOCS is worthy of purchase. However, be prepared for the increased complexity of the program. Also, we recommend that our customers be careful to receive a quotation for all the options that you will expect with DOCS (like TSM).

Communication with Supravision Network Protocol

See this link for information on which version of DOCS will communicate using SVNET: [1]


Principles for Communication with SVNET and DOCS

Principles

Reasons

If the data at the bender control has changed and...

You anticipate the possibility of a correction sent to the bender then...

Perform a RECALL before a MEASURE and BEST FIT

A RECALL from a bender clears the results of a measure - so it is important to RECALL the latest bender data from the bender as a first step through Benderlink if the CLRA data in DOCS does not match the bender's LRA values.

If the bender data has changed at the bender control before the current part is measured for correctness, then follow these steps:

  1. RECALL the latest tube data from the bender control

  2. MEASURE the tube and apply a tangent point fit

  3. CORRECT the Corrected LRA values by viewing the properties page, clicking on the CLRA tab, and pressing UPDATE.

  4. SEND the Corrected LRA values through Benderlink to the bender.


After a RECALL from the bender...

...be careful to confirm that the incoming data changed the CLRA section of the data alone (and not the nominal LRA).

  1. If a matching part number is found in memory in DOCS, then DOCS applies the incoming bender data to the CORRECTED LRA data.

  2. If the part number DOES NOT MATCH, then DOCs may assume that you intend to create a new MASTER part with the incoming data - and update the NOMINAL data.

If you have a version of DOCS of 2.2 or 2.3 and previous to Dec 20, 2007 in file date, then...

be sure to upgrade before attempting corrections loops.

Earlier DOCS versions of 2.3 change the NOMINAL LRA data during a RECALL. (Only the CORRECTED LRA data should be updated.)