Difference between revisions of "CNC Bender v14.9-r10"
From ATTWiki
(→25px ENHANCEMENT: Cross Slide Check) |
(→25px ENHANCEMENT: SUPRAVISION Communication Change for ROMER Software) |
||
Line 23: | Line 23: | ||
This has been changed so that CNC Bender now only examines the Cross Slide input prox for ADVANCED or IN the die active.<br><br> | This has been changed so that CNC Bender now only examines the Cross Slide input prox for ADVANCED or IN the die active.<br><br> | ||
'''This allows for locking the carriage cross slide for little or no movement - with both HOME and ADVANCED proximity switches active at the same time - and still close the dies.''' | '''This allows for locking the carriage cross slide for little or no movement - with both HOME and ADVANCED proximity switches active at the same time - and still close the dies.''' | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
</td> | </td> | ||
</tr> | </tr> |
Revision as of 14:23, 12 March 2016
v14.9-r10 - March 10, 2015
|
ENHANCEMENT: Cross Slide Check
In previous versions of CNC Bender, the internal logic would not allow the manual jog close of either PRESSURE die or CLAMP die if the Cross Slide input prox for AWAY from die (or in the home position) was active. |
Other Pages
- Back to CNC Bender
- Back to CNC Bender Software Updates
- See CNC Bender Customer Service Page for an update.
- See CNC Bender General Information
- See Teach Mode
- See Custom Commands