Difference between revisions of "Romer"
(→Calibration Probes) |
|||
(14 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
− | |||
− | |||
− | = | + | <table> |
− | + | <tr> | |
+ | <td width=200> | ||
+ | As of November of 2017, our [[VTube-LASER]] is compatible with any ROMER arm that uses a ball probe and/or laser scanner through the RDS driver. | ||
+ | <br><br> | ||
+ | * See [[RDS Versions for ROMER Scanners]]<br><br> | ||
+ | * See [[VTUBE-iMC]] - Tube Measuring System with ROMER Absolute Arms<br><br> | ||
+ | * See [[ROMER Ball Probes]]<br><br> | ||
+ | * See [[ROMER Certified Length Bar]]<br><br> | ||
+ | |||
+ | </td> | ||
+ | <td> | ||
+ | [[image:ROMER_Scanner_Plus_Hex_Logo.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <table> | ||
+ | <tr> | ||
+ | <td width=200> | ||
+ | The older ROMER arms were a measuring center well-known for its [[Supravision]] software and portable measuring centers. As of the turn of the century, Romer had begun replacing [[Supravision]] with the newer [[DOCS]] software.<br><br> | ||
+ | HEXAGON purchased the ROMER brand in December, 2004. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:romer_infinite.jpg]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | __NOTOC__ | ||
+ | |||
− | ==Bender Connection== | + | ==Bender Connection using Benderlink Software== |
* Our [[Benderlink Ethernet Module]] allows Romers with Supravision or DOCS to connect to any VELOG, EL-2000, or Premier Eaton Leonard bender control. | * Our [[Benderlink Ethernet Module]] allows Romers with Supravision or DOCS to connect to any VELOG, EL-2000, or Premier Eaton Leonard bender control. | ||
Line 19: | Line 46: | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
==Tube Measuring Probes== | ==Tube Measuring Probes== | ||
Line 27: | Line 53: | ||
<tr> | <tr> | ||
<td width=200> | <td width=200> | ||
− | ROMER arms use infrared probes to measure tube shapes.<br><br> | + | Some ROMER arms use infrared probes to measure tube shapes.<br><br> |
The probe shown here is the 25mm probe (also called the 1 inch probe) | The probe shown here is the 25mm probe (also called the 1 inch probe) | ||
</td> | </td> | ||
Line 37: | Line 63: | ||
</table> | </table> | ||
− | |||
==Calibration Probes== | ==Calibration Probes== | ||
Line 49: | Line 74: | ||
<td> | <td> | ||
[[image:romer_15mmballprobe.jpg|thumb]]<br> | [[image:romer_15mmballprobe.jpg|thumb]]<br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | |||
+ | </table> | ||
+ | |||
+ | |||
+ | |||
+ | ==Calibration Bars== | ||
+ | <table> | ||
+ | |||
+ | <tr> | ||
+ | <td width=200> | ||
+ | This is commonly called a T-Bar.<br><br> | ||
+ | It is used to calibrate the tube measuring probes. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:romer_tbar.jpg|thumb]]<br> | ||
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 19:33, 19 May 2018
As of November of 2017, our VTube-LASER is compatible with any ROMER arm that uses a ball probe and/or laser scanner through the RDS driver.
|
The older ROMER arms were a measuring center well-known for its Supravision software and portable measuring centers. As of the turn of the century, Romer had begun replacing Supravision with the newer DOCS software. |
Bender Connection using Benderlink Software
- Our Benderlink Ethernet Module allows Romers with Supravision or DOCS to connect to any VELOG, EL-2000, or Premier Eaton Leonard bender control.
|
Tube Measuring Probes
Some ROMER arms use infrared probes to measure tube shapes. |
See the source page for this image. |
Calibration Probes
ROMER arms uses ball probes for calibration of the arm. |
|
Calibration Bars
This is commonly called a T-Bar. |
|