Difference between revisions of "End-Scan Using the Scissor Motion"
From ATTWiki
(→Measure Setup) |
(→About the Scissor Orientation - Easy But Least Precise) |
||
(23 intermediate revisions by one user not shown) | |||
Line 5: | Line 5: | ||
How to perform quick scissor motion end-scans.<br><br> | How to perform quick scissor motion end-scans.<br><br> | ||
* Back to [[VTube-LASER]] | * Back to [[VTube-LASER]] | ||
+ | * See [[End-Scan Technique Research]] | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Line 14: | Line 15: | ||
− | === | + | ===About the Scissor Orientation - Easy But Least Precise=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | This end-scan method is useful for ease-of-use and quickness. | + | This end-scan method is useful for ease-of-use and quickness, however it is the least precise of the techniques. |
<br><br> | <br><br> | ||
− | + | You can expect about 0.1 inches (2.5mm) of repeatability in end lengths when using this method for end scans. | |
<br><br> | <br><br> | ||
− | We also recommend | + | We also recommend these techniques: |
+ | |||
+ | * [[End-Scan Using the End Wall]] | ||
+ | * [[End-Scan Using End Targets]] (most precise) | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Line 29: | Line 33: | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
===Measure Setup=== | ===Measure Setup=== | ||
Line 37: | Line 40: | ||
* Set System Options, Measure 2 Tab, "Maximum Number of LLP Points in String" to 3 | * Set System Options, Measure 2 Tab, "Maximum Number of LLP Points in String" to 3 | ||
* Set Measure Setup - LASER Tab: The LASER defaults to ON for CYLINDERS and END-SCANS. | * Set Measure Setup - LASER Tab: The LASER defaults to ON for CYLINDERS and END-SCANS. | ||
− | * Set Measure Setup - LASER Tab | + | * Set Measure Setup - LASER Tab: Cylinder stripes = 3 to 5 |
− | * Set Measure Setup - LASER Tab | + | * Set Measure Setup - LASER Tab: End-scan stripes = 5 |
− | * Set Measure Setup - LASER Tab | + | * Set Measure Setup - LASER Tab: Split bend stripes = 5 |
− | * Set | + | * Set Measure Setup = Scan Rates Tab: Set all rates to TIMER for all scan types. |
− | * Set | + | * Set Measure Setup = Scan Rates Tab: Set the Scan Rates TIMER is set to 0 for all TIMERS. |
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Line 54: | Line 57: | ||
<td width=300> | <td width=300> | ||
* Align the scanner with a slight scissor angle across the end as is shown in the image on the right<br><br> | * Align the scanner with a slight scissor angle across the end as is shown in the image on the right<br><br> | ||
+ | * Attempt to hold the laser motionless when collecting the stripes across the end to increase repeatability.<br><br> | ||
+ | * Consistently place the line across the same area of the tube end from measure to measure.<br><br> | ||
*Press the green button until VTube-LASER is finished scanning all the end stripes.<br><br> | *Press the green button until VTube-LASER is finished scanning all the end stripes.<br><br> | ||
− | [[image:EndWithScissorCloseup.jpg|300px]] | + | [[image:EndWithScissorCloseup.jpg|300px]]<br><br> |
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Line 62: | Line 67: | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
===Other Pages=== | ===Other Pages=== |
Latest revision as of 15:20, 1 December 2016
How to perform quick scissor motion end-scans.
|
About the Scissor Orientation - Easy But Least Precise
This end-scan method is useful for ease-of-use and quickness, however it is the least precise of the techniques.
|
Measure Setup
|
How To Use This End-Scan Technique
|
Other Pages
- See also End-Scan Using the End Wall
- See also End-Scan Using End Targets
- Back to VTube-LASER