Difference between revisions of "Cable Spec 35"
From ATTWiki
(→Breakout Tester) |
|||
(4 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
+ | |||
+ | __TOC__ | ||
+ | |||
+ | ==Cable Pinout== | ||
<table> | <table> | ||
<tr> | <tr> | ||
Line 13: | Line 17: | ||
[[image:db9_rej45_cb-el1_pinout.jpg|800px]] <be> | [[image:db9_rej45_cb-el1_pinout.jpg|800px]] <be> | ||
+ | <br><br> | ||
+ | ==Breakout Tester for Cable 35== | ||
+ | Use a breakout tester for continuity checks like this: | ||
+ | <br><br> | ||
+ | [[image:cable_CB-EL1_breakout_test.png|800px]] | ||
+ | |||
+ | ==In the Box== | ||
<table> | <table> | ||
<tr> | <tr> | ||
<td width=500> | <td width=500> | ||
− | This is an image of an RJ45 to DB9 adapter with the above wiring. The DB9 port is female to attach to a standard PC male port. | + | This is an image of an RJ45 to DB9 adapter with the above wiring inside the benderlink ethernet module. The DB9 port is female to attach to a standard PC male port. |
</td> | </td> | ||
<td> | <td> | ||
Line 26: | Line 37: | ||
</table> | </table> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<table> | <table> |
Latest revision as of 16:53, 23 August 2022
Contents |
Cable Pinout
This is the wiring schematic for the RJ45 to DB9 female adapter for the CB-EL1 RS232D port on the board. |
Breakout Tester for Cable 35
Use a breakout tester for continuity checks like this:
In the Box
This is an image of an RJ45 to DB9 adapter with the above wiring inside the benderlink ethernet module. The DB9 port is female to attach to a standard PC male port. |
Other Pages
- Back to Cable Specs