Difference between revisions of "VTube-LASER v2.8"

From ATTWiki
Jump to: navigation, search
(25px ENHANCED: Winton WMC Communications Improvement)
(25px ENHANCED: Winton WMC Communications Improvement)
Line 81: Line 81:
 
<br><br>
 
<br><br>
  
[[image:vtl_v2.8_winton_correction_existing_dialog.png|300px]]<br><br>
 
[[image:vtl_v2.8_winton_correction_overwrite_backup_dialog.png|300px]]<br><br>
 
 
<td>
 
<td>
 
</td>
 
</td>
 
<td>
 
<td>
 +
New Dialogs During Correction: <br>
 +
[[image:vtl_v2.8_winton_correction_existing_dialog.png|600px]]<br><br>
 +
[[image:vtl_v2.8_winton_correction_overwrite_backup_dialog.png|600px]]<br><br>
 +
 +
Overall Corrections Process: <br>
 
[[image:vtl_v2.8_winton_correction_process.png|600px]]<br><br>
 
[[image:vtl_v2.8_winton_correction_process.png|600px]]<br><br>
  

Revision as of 01:06, 4 March 2017

Vtube-laser logo 1.96.png


Revision 2.8

Release Date: Not Released


Vtube-laser v2.7 screenshot.png

Contents


BUILD 11 - February 15, 2017

Check.jpg NEW: "Default Tolerance Ends" Value

The Default Tolerance Ends value is in the Inspection Data menu.

It allows you to set the end length default values separately from the tangent point / midpoint tolerance values.

Vtl-v2.8 Default End Tolerance.png




Check.jpg NEW: REPORT COMMANDS - Tangent Deviation AVERAGE and MAXIMUM Values

Two new array values are available for reports: AVERAGE deviation and MAXIMUM deviation.

The new commands are

  • array_dev_tmt_average
  • array_dev_tmt_maximum



See the example result in the report on the right, and the report template source to create this table shown below.

Vtl-2.8 inspection data tangent average and maximum html sample.png




Vtl-2.8 inspection data tangent average and maximum.png




BUILD 19 - February 22, 2017

Check.jpg ENHANCED: Winton WMC Communications Improvement

The process for corrections to Winton WMC files were clarified with dialogs that make it very clear what VTube-LASER Bender Setup is doing during the Winton WMC correction process.

Steps 2 and 5 are new. They carefully explain what is happening during the correction process.

Step 5 also explains that a BACKUP file is created during the process. This allows operators to always get back to the previous data if something goes wrong in the correction process.

New Dialogs During Correction:
Vtl v2.8 winton correction existing dialog.png

Vtl v2.8 winton correction overwrite backup dialog.png

Overall Corrections Process:
Vtl v2.8 winton correction process.png



Check.jpg NEW: REPORT COMMANDS - Tangent Deviation AVERAGE and MAXIMUM Values

Two new array values are available for reports: AVERAGE deviation and MAXIMUM deviation.

The new commands are

  • array_dev_tmt_average
  • array_dev_tmt_maximum



See the example result in the report on the right, and the report template source to create this table shown below.

Vtl-2.8 inspection data tangent average and maximum html sample.png




Vtl-2.8 inspection data tangent average and maximum.png