* Align the scanner with a slight scissor angle across the end as is shown in the image on the right<br><br>
 
* Align the scanner with a slight scissor angle across the end as is shown in the image on the right<br><br>
*The solution is to use white targets on the end of the tubes.  The example here shows white poly labels that measure at 0.004" thick and provide an excellent flat target for the laser.<br><br>(Note: Use the Plane-Point measurement in the built-in computer of the FARO Edge to confirm the thickness of the target.)<br><br>
+
*Press the green button until VTube-LASER is finished scanning all the end stripes.
* The offset from the target to the tube end is entered as a negative value in the Part Setup menu for either end.  In this case, we use -0.004" offset.<br><br>
+
*Any shape of target works well as long as it is LARGER than the diameter of the tube.  Apply the target so that none of the end-wall can be scanned by the laser.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>

Revision as of 22:35, 27 January 2012

Vtube-laser logo.jpg How to perform quick scissor motion end-scans.

Vtube-laser 1 73.jpg


Why the End-Scan technique is important

This end-scan method is useful for ease-of-use and quickness.

Please keep in mind that our tests show that it is the least precise of the techniques that we recommend.

We also recommend the End-Scan Using the End Wall technique and the most precise End-Scan Using End Targets.

Align the Scanner

  • Align the scanner with a slight scissor angle across the end as is shown in the image on the right

  • Press the green button until VTube-LASER is finished scanning all the end stripes.

EndWithScissor.jpg

Measure the Target

When it is time to perform and end-scan, use the following technique to scan the target:

  • Aim the laser at the target so that it strikes the target as perpendicular to the surface as possible. Avoid returning any points other than the target.

  • Hold the laser still when collecting the stripes across the target.
  • Consistently place the line across the same area of the target from measure to measure.

EndWithTargetAndLaser.jpg
EndWithTargetAndLaserCloseup.jpg

Approve the Measurement On the Screen

  • The resulting geometry on the screen should appear like the image at he right.

  • The end point generated on the screen should perfectly coincide with the stripes.

EndScanAfterTarget.jpg

Using End Target Adapters



  • If you prefer using more durable end target adapter that plugs into the end of the tube, then they can be manufactured for repeatable measurements.

  • The end target surface should be painted or covered with a flat white or near-white target.

  • The offset from the target to the tube end is entered as a negative value in the Part Setup menu for either end.

EndTargetPlugDesign.jpg