Difference between revisions of "VTube-LASER v2.9.17"
(→25pxFIX - 180-degree Bender Correction Feature) |
(→25pxFIX - 180-degree Bend Correction Feature) |
||
Line 128: | Line 128: | ||
<td width=300> | <td width=300> | ||
− | '''This is important | + | '''This is important to you if you correct benders with 180-degree bends using Bender Setup communications.'''<br><br> |
The Split Bend corrections (for a 180-degree bend) were being applied in Bender Setup in the uncompressed mode - which means that only half the correction was being applied to 180-degree bends.<br><br>Also, the wrong number of rows was sent to Bender Setup - which meant that correction data was not properly aligned with the data at the bender. For example, for a single 180-degree bend part, there should only be two correction rows. However, VTube was sending three rows of data for two 90-degree bends.<br><br> | The Split Bend corrections (for a 180-degree bend) were being applied in Bender Setup in the uncompressed mode - which means that only half the correction was being applied to 180-degree bends.<br><br>Also, the wrong number of rows was sent to Bender Setup - which meant that correction data was not properly aligned with the data at the bender. For example, for a single 180-degree bend part, there should only be two correction rows. However, VTube was sending three rows of data for two 90-degree bends.<br><br> | ||
This has been fixed in this version.<br><br> | This has been fixed in this version.<br><br> |
Revision as of 02:10, 21 December 2018
Revision 2.9.17Release Date: Unreleased
|
NEW - VTube-LASER Now Automatically Resets Straight Count at Measure
VTube-LASER users are used to editing from a "0" for starting straight count to some positive value. You won't have to do that any more in this new version - because now VTube will just fill in the correct straight count for you. You can still change it manually at any time. |
NEW - Scan and Measure Point Clouds into Point Cloud "Buckets"
VTube-LASER now handles point clouds in storage we call "buckets." This allows you to scan anything into VTube-LASER - not just tubes. With this feature:
|
NEW - Store Cylinder Fit Tolerances for Reuse in Other Projects
The new Cylinder Fit Tolerances Named Setup feature allows you to store cylinder fit tolerances in Measure 1 for measuring cylinders for use in other projects. Each setup is stored in a list of named setups that can be used in any other project.
|
NEW - MAX Points for Cylinder Stripes Is Now 50
Through some experimentation, any point count above 50 per stripe is not helpful in VTube-LASER. For example, as you approach 1000 points per stripe, it slows the math engine significantly and actually causes more Cylinder Fit problems than it solves. |
FIX - 180-degree Bend Correction Feature
This is important to you if you correct benders with 180-degree bends using Bender Setup communications. |
NEW- Auto Disconnect When the FARO Driver is Busy
When the FARO driver is busy with other connections (like to CAM2), VTube-LASER would give an error then shutdown. |
NEW- Auto Display of DRO (Digital Readout) When Moving from VTube-STEP to VTube-LASER
When the arm is connected to VTube, and the user changes from VTube-STEP to VTube-LASER, VTube now automatically displays the DRO window (Digital Readout). |
Other Changes
- For HTML reports, the screen-image bmp file is now only copied to the html export folder when it is present in the html report.
- In VTube-STEP, the export html report feature would display an error and would not save he html reports. This has been fixed.
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature