Difference between revisions of "CNC Bender v12-20101021"

From ATTWiki
Jump to: navigation, search
(25px NEW - Added Input Timer in PreEnable)
(25px NEW - FEED AXIS POSITION DISPLAY FROM BACK OR FRONT)
Line 26: Line 26:
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] NEW - FEED AXIS POSITION DISPLAY FROM BACK OR FRONT ===
+
===[[image:Check.jpg|25px]] FIXED - Early Mandrel Extra On Last Bend ===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
The FEED axis values can be displayed from the front or the back by pressing a toggle button in the RUN PAGE.<br><br>
+
For benders with motion controlled PDA, the early mandrel extract did not work on the last bend.<br><br>
This changes all FEED Position values displayed in CNC Bender.
+
This has been repaired so that the feature works.
 
</td>
 
</td>
 
<td>
 
<td>
[[image:feeddatum_change.jpg|350px]]
+
[[image:ball_mandrel.jpg]]
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 20:04, 22 October 2010

Cncv12procontrol withteachmode.jpg

Contents


Check.jpg NEW - Added Input Timer in PreEnable

Schneider Lexium drives require a pulse to switch from READY to RUN mode. This feature was added to allow for pulsing Lexium drives a specific amount of time before the axes were enabled.

Lexium drive motor.jpg

Check.jpg FIXED - Early Mandrel Extra On Last Bend

For benders with motion controlled PDA, the early mandrel extract did not work on the last bend.

This has been repaired so that the feature works.

Ball mandrel.jpg

Check.jpg NEW - FEED TORQUE ZEROED DURING MANDREL RETRACT

The FEED TORQUE is now set to ZERO% during mandrel retractions. This prevents possible destruction of the FEED gearbox, rack, pinion, chain, if the tube breaks during bending and the mandrel pulls the tube and carriage back.