− | ===[[image:Check.jpg|25px]] NEW - Added Input Timer in PreEnable === | + | ===[[image:Check.jpg|25px]] NEW - Added Input Timer in PreEnable Processlist === |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | Schneider Lexium drives require a pulse to switch from READY to RUN mode. | + | Schneider Lexium drives require a pulse to switch from READY to RUN mode. <br><br> |
+ | |||
+ | Input TIMERS are now allowed in the PreEnable processlist to pulse the Lexium drives with an output point for a specific amount of time before the axes were enabled.<br><br> | ||
</td> | </td> | ||
<td> | <td> | ||
Line 26: | Line 28: | ||
</table> | </table> | ||
− | ===[[image:Check.jpg|25px]] FIXED - Early Mandrel | + | ===[[image:Check.jpg|25px]] FIXED - Early Mandrel Extract On Last Bend === |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | For benders with motion controlled PDA - the early mandrel extract now works.<br><br> | + | For benders with motion-controlled [[PDA]] - the early mandrel extract now works.<br><br> |
− | (Image | + | (Image courtesy of [http://www.toolsforbending.com/mandrels.asp Tools For Bending web site]) |
</td> | </td> | ||
<td> | <td> | ||
Line 47: | Line 49: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | The keyboard features were completely locked out of previous user interfaces to prevent a problem with accidental motion in the MANUAL page. This was too drastic and restrictive for operators that wanted to use the keyboard. | + | The keyboard features were completely locked out of previous main-window user interfaces to prevent a problem with accidental motion in the MANUAL page. This was too drastic and restrictive for operators that wanted to use the keyboard. |
<br><br> | <br><br> | ||
− | Now the keyboard works in every part of the user interface except | + | Now the keyboard works in every part of the user interface except with the manual buttons that can cause motion. Manual buttons will not receive any keyboard input. |
</td> | </td> | ||
<td> | <td> | ||
− | [[image:keyboard.jpg]] | + | [[image:keyboard.jpg|150px]] |
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 21:05, 22 October 2010
Contents |
NEW - Added Input Timer in PreEnable Processlist
Schneider Lexium drives require a pulse to switch from READY to RUN mode. Input TIMERS are now allowed in the PreEnable processlist to pulse the Lexium drives with an output point for a specific amount of time before the axes were enabled. |
FIXED - Early Mandrel Extract On Last Bend
For benders with motion-controlled PDA - the early mandrel extract now works. |
CHANGED- KEYBOARD HANDLING
The keyboard features were completely locked out of previous main-window user interfaces to prevent a problem with accidental motion in the MANUAL page. This was too drastic and restrictive for operators that wanted to use the keyboard.
|