(25px ENHANCED: New Options in Part Setup)
(25px NEW: Automatically Set a ZERO Default Radius to 1.5 Times the Diameter)
Line 49: Line 49:
  
 
===[[image:Check.jpg|25px]] NEW: Automatically Set a ZERO Default Radius to 1.5 Times the Diameter===
 
===[[image:Check.jpg|25px]] NEW: Automatically Set a ZERO Default Radius to 1.5 Times the Diameter===
 
+
[[image:vtube-laser_automatic_default_radius_setup.jpg|500px]]
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
 
If VTube discovers a default radius value of ZERO, then it will automatically reset the default radius to 1.5 times the nominal diameter before converting to the measured menu.<br><br>
 
If VTube discovers a default radius value of ZERO, then it will automatically reset the default radius to 1.5 times the nominal diameter before converting to the measured menu.<br><br>
[[image:vtube-laser_automatic_default_radius_setup.jpg|300px]]
 
 
</td>
 
</td>
  

Revision as of 21:42, 4 March 2011

Vtube-laser logo.jpg

Revision 1.61

Back to VTube-LASER

Vtube-laser 1 61.jpg



Check.jpg NEW: Floating End Letters

Floating end letters can be switched on to help identify the ends A and B of the tube.

Control the state of the labels in the View Control pane on the right side of the screen.

Vtube-laser floating end labels checkbox.jpg

Vtube-laser floating end labels.jpg



Check.jpg NEW: Can Automatically Expanded or Reduced End A and End B Diameter

If either End A or End B are set to a value of ZERO, then they will be automatically calculated based on the straight measurement adjacent to the end of the tube.

The Part Setup on the right is from a measurement of B end tube straight where a 1.130" expansion was measured. End B was set to zero, and VTube automatically filled in the expanded end diameter.

Vtube-laser partsetup grid autoset enddiameter.jpg



Check.jpg NEW: Automatically Set a ZERO Default Radius to 1.5 Times the Diameter

Vtube-laser automatic default radius setup.jpg

If VTube discovers a default radius value of ZERO, then it will automatically reset the default radius to 1.5 times the nominal diameter before converting to the measured menu.



Check.jpg Other Changes

  • Better math handling when the radius is set to zero.

  • Much more efficient redraws in the view port

  • Small user interface fixes and refinements

  • The maximum number of LLP strings per measure allowed is increased in the Measure 2 tab of the Systems Options menu.

  • The Measure a Tube control is changed to allow you to qualify the image on the screen before exiting the measure process. This adds a step to the measure process.

  • Include End A Diameter and End B Diameter variables in Supravision file import and export.

  • New help file and manual with updates and additional sections like "How to Scan a Straight."

Vtube-laser finish apply measure 1 6.jpg



Check.jpg Issues with this version fixed in next version

  • No known issues

Other Pages