Difference between revisions of "VTube-LASER v1.63"

From ATTWiki
Jump to: navigation, search
 
(25px Other Changes)
 
(26 intermediate revisions by one user not shown)
Line 16: Line 16:
  
 
===[[image:Check.jpg|25px]] NEW: Select and Configure any number of Reports===
 
===[[image:Check.jpg|25px]] NEW: Select and Configure any number of Reports===
 +
[[image:vtube-laser_report_templates_list.jpg|500px]]<br><br>
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
 
The Report menu was redesigned so that operators choose from a list of report templates to show any one of several reports.<br><br>
 
The Report menu was redesigned so that operators choose from a list of report templates to show any one of several reports.<br><br>
*Edit the list (Add, Delete, Move the template up or down).
+
*Give each report template a name that is linked to an external report template file.<br><br>
*Edit any template in the included Notepad++ editor (installs with v1.63).
+
*Change the list (Add, Delete, Move the template up or down).<br><br>
*Explore the folder that contains the templates.
+
*Edit any template in the included Notepad++ editor (installs with v1.63).<br><br>
*Give the report template a new name.
+
*Explore the folder that contains the templates.<br><br>
*There is no limitation on the number of templates allowed.
+
*There is no limitation on the number of templates allowed.<br><br>
*The report template setup is stored local to the computer (not in project files).
+
*The report template setup is stored local to the computer (not in project files).<br><br>
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 35: Line 36:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] NEW: Scan Rate Types: Timer or Distance===
+
===[[image:Check.jpg|25px]] NEW: Added LENGTH grid in the Inspection Menu===
 +
[[image:vtube-laser_length_grid_closeup.jpg|500px]]<br><br>
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
Now all scan rates are determined by either a TIMER or a DISTANCE.
+
The new Length grid shows the MASTER, MEASURED, and differences between the two.<br><br>
<br><br>
+
Use these values to know how much to change the pre-bending material cut length.<br><br>
For end-scans, use a timer and set the timer value to 0 milliseconds.<br><br>
+
The Crosscheck values were moved into this grid.  (Crosscheck is a measure of the straight line from end A to end B.)<br><br>
For cylinder scans, you can use DISTANCE and set the Cylinder Scan Distance to whatever value is convenient for separation.
+
</td>
+
<td width=300>
+
[[image:vtube-laser_measuresetup_scanrates.jpg|300px]]<br><br>
+
</td>
+
</tr>
+
</table>
+
  
<br><br>
 
 
===[[image:Check.jpg|25px]] NEW: Multiple Point Qualification End Scan===
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=200>
 
VTube-LASER now uses multiple points to qualify the end-scan.  This gives it better protection against outlier points.<br><br>
 
A new End-Scan Fit window gives information about how many points were used in the end-trim, and the span of all the point positions.  Higher point counts with lower spans indicate a better data set for end-trim.
 
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_endscan_fitwindow.jpg|300px]]<br><br>
+
[[image:vtube-laser_length_grid.jpg|300px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 67: Line 54:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] REPAIR: Diameter and Wall Detection for STEP Mode===
+
===[[image:Check.jpg|25px]] Other Changes===
 
+
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=200>
 
<td width=200>
See [[VTube-STEP v1.62]] for details.</td>
+
*Updated the graphics engine for faster redraws.<br><br>
<td width=30>
+
*Added more report values - master length, measured length, delta between measured and master, bender setup LRA<br><br>
[[image:Vtube-step_1_62.jpg|300px]]
+
*Updated the manual and help file.<br><br>
 +
*Now include the Notepad++ editor with the installation of VTube-LASER for editing HTML Report Templates.<br><br>
 +
*New graphics images in the Measure Setup menu to make the menus easier to identify quickly.<br><br>
 +
*Opened the end-scan tolerance for radius segment scanning to 10 times the tolerance for regular end-scans. This allows for measuring highly deformed cylinders inside a radius.<br><br>
 +
*Diameter measures now use the Cylinder scan rate filter setup values.<br><br>
 +
*Diameter measures automatically enable only the SCANNED and CALCULATED data on the screen.<br><br>
 
</td>
 
</td>
</tr>
 
</table>
 
 
<br><br>
 
 
===[[image:Check.jpg|25px]] Other Changes ===
 
<table>
 
<tr>
 
 
<td width=300>
 
<td width=300>
* The A End and B End OFFSETs other than ZERO caused a problem where end-scans would never be qualified. This has been resolved in this version.
+
[[image:vtube_laser_mastermeasurelengths_report.jpg|300px]]<br>
</td>
+
[[image:vtube_laser_measuresetup_laser.jpg|300px]]<br>
<td>
+
[[image:vtube_laser_diametermeasure_scanned_and_calculated.jpg|300px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 104: Line 87:
 
</tr>
 
</tr>
 
</table>
 
</table>
 +
 +
<br><br>
  
 
=Other Pages=
 
=Other Pages=

Latest revision as of 16:58, 1 April 2011

Vtube-laser logo.jpg

Revision 1.63

Back to VTube-LASER

Vtube-laser 1 63.jpg



Check.jpg NEW: Select and Configure any number of Reports

Vtube-laser report templates list.jpg

The Report menu was redesigned so that operators choose from a list of report templates to show any one of several reports.

  • Give each report template a name that is linked to an external report template file.

  • Change the list (Add, Delete, Move the template up or down).

  • Edit any template in the included Notepad++ editor (installs with v1.63).

  • Explore the folder that contains the templates.

  • There is no limitation on the number of templates allowed.

  • The report template setup is stored local to the computer (not in project files).

Vtube-laser report templates control.jpg



Check.jpg NEW: Added LENGTH grid in the Inspection Menu

Vtube-laser length grid closeup.jpg

The new Length grid shows the MASTER, MEASURED, and differences between the two.

Use these values to know how much to change the pre-bending material cut length.

The Crosscheck values were moved into this grid. (Crosscheck is a measure of the straight line from end A to end B.)

Vtube-laser length grid.jpg



Check.jpg Other Changes

  • Updated the graphics engine for faster redraws.

  • Added more report values - master length, measured length, delta between measured and master, bender setup LRA

  • Updated the manual and help file.

  • Now include the Notepad++ editor with the installation of VTube-LASER for editing HTML Report Templates.

  • New graphics images in the Measure Setup menu to make the menus easier to identify quickly.

  • Opened the end-scan tolerance for radius segment scanning to 10 times the tolerance for regular end-scans. This allows for measuring highly deformed cylinders inside a radius.

  • Diameter measures now use the Cylinder scan rate filter setup values.

  • Diameter measures automatically enable only the SCANNED and CALCULATED data on the screen.

Vtube laser mastermeasurelengths report.jpg
Vtube laser measuresetup laser.jpg
Vtube laser diametermeasure scanned and calculated.jpg



Check.jpg Issues with this version fixed in newer versions

  • No known issues



Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg