Difference between revisions of "VTube-LASER v1.63"
From ATTWiki
(13 intermediate revisions by one user not shown) | |||
Line 16: | Line 16: | ||
===[[image:Check.jpg|25px]] NEW: Select and Configure any number of Reports=== | ===[[image:Check.jpg|25px]] NEW: Select and Configure any number of Reports=== | ||
+ | [[image:vtube-laser_report_templates_list.jpg|500px]]<br><br> | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
Line 34: | Line 35: | ||
<br><br> | <br><br> | ||
− | |||
===[[image:Check.jpg|25px]] NEW: Added LENGTH grid in the Inspection Menu=== | ===[[image:Check.jpg|25px]] NEW: Added LENGTH grid in the Inspection Menu=== | ||
+ | [[image:vtube-laser_length_grid_closeup.jpg|500px]]<br><br> | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
Line 59: | Line 60: | ||
*Updated the graphics engine for faster redraws.<br><br> | *Updated the graphics engine for faster redraws.<br><br> | ||
*Added more report values - master length, measured length, delta between measured and master, bender setup LRA<br><br> | *Added more report values - master length, measured length, delta between measured and master, bender setup LRA<br><br> | ||
− | *Updated the manual and help file.<br> | + | *Updated the manual and help file.<br><br> |
+ | *Now include the Notepad++ editor with the installation of VTube-LASER for editing HTML Report Templates.<br><br> | ||
+ | *New graphics images in the Measure Setup menu to make the menus easier to identify quickly.<br><br> | ||
+ | *Opened the end-scan tolerance for radius segment scanning to 10 times the tolerance for regular end-scans. This allows for measuring highly deformed cylinders inside a radius.<br><br> | ||
+ | *Diameter measures now use the Cylinder scan rate filter setup values.<br><br> | ||
+ | *Diameter measures automatically enable only the SCANNED and CALCULATED data on the screen.<br><br> | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
+ | [[image:vtube_laser_mastermeasurelengths_report.jpg|300px]]<br> | ||
+ | [[image:vtube_laser_measuresetup_laser.jpg|300px]]<br> | ||
+ | [[image:vtube_laser_diametermeasure_scanned_and_calculated.jpg|300px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 67: | Line 76: | ||
<br><br> | <br><br> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
===[[image:Check.jpg|25px]] Issues with this version fixed in newer versions=== | ===[[image:Check.jpg|25px]] Issues with this version fixed in newer versions=== | ||
Line 84: | Line 87: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
+ | <br><br> | ||
=Other Pages= | =Other Pages= |
Latest revision as of 16:58, 1 April 2011
Revision 1.63Back to VTube-LASER |
NEW: Select and Configure any number of Reports
The Report menu was redesigned so that operators choose from a list of report templates to show any one of several reports.
|
NEW: Added LENGTH grid in the Inspection Menu
The new Length grid shows the MASTER, MEASURED, and differences between the two. |
Other Changes
|
Issues with this version fixed in newer versions
|
Other Pages
- Back to VTube-LASER
VTube-LASER Training Video - How to perform effective end scans. |