Difference between revisions of "VTube-LASER v1.65"
(→Revision 1.65) |
|||
(18 intermediate revisions by one user not shown) | |||
Line 7: | Line 7: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:vtube- | + | [[image:vtube-laser_screen_1_65.jpg|300px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 15: | Line 15: | ||
===[[image:Check.jpg|25px]] NEW: Radius Correction for Push-Bending=== | ===[[image:Check.jpg|25px]] NEW: Radius Correction for Push-Bending=== | ||
− | [[image:vtube-laser_1_65_radiuscorrection.jpg| | + | [[image:vtube-laser_1_65_radiuscorrection.jpg|425px]]<br><br> |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
Line 23: | Line 23: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:vtube-laser_1_65_radiusstripescan_sendradius.jpg| | + | [[image:vtube-laser_1_65_radiusstripescan_sendradius.jpg|200px]] |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
<br><br> | <br><br> | ||
Line 36: | Line 37: | ||
<td width=200> | <td width=200> | ||
The Bender Setup window has a new easier-to-view color scheme.<br><br> | The Bender Setup window has a new easier-to-view color scheme.<br><br> | ||
+ | * ORANGE Columns are NEW ADJUSTED data to be sent out to the bender.<br> | ||
+ | * BLUE Columns contain the current bender setup before adjustment. | ||
+ | |||
The bend setup grid has a new column for inverting rotations that are sent out to the bender. This allows for sending the rotation the opposite direction - then remembering the inversion for next time the project is run. | The bend setup grid has a new column for inverting rotations that are sent out to the bender. This allows for sending the rotation the opposite direction - then remembering the inversion for next time the project is run. | ||
</td> | </td> | ||
Line 46: | Line 50: | ||
<br><br> | <br><br> | ||
− | ===[[image:Check.jpg|25px]] ENHANCED: New Torus-fit | + | ===[[image:Check.jpg|25px]] ENHANCED: New Torus-fit Engine for Radius Stripe Scanning=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
Line 69: | Line 73: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | |||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | [[image:vtube-laser_1_65_benderpluscorrections.jpg|500px]] | ||
<br><br> | <br><br> | ||
− | |||
===[[image:Check.jpg|25px]] ENHANCED: Report Preview Menu=== | ===[[image:Check.jpg|25px]] ENHANCED: Report Preview Menu=== | ||
Line 84: | Line 87: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | |||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | [[image:vtube-laser_1_65_reportpreview.jpg|400px]] | ||
<br><br> | <br><br> | ||
− | |||
− | |||
===[[image:Check.jpg|25px]] ENHANCED: Measure Setup - Laser Probe Grid=== | ===[[image:Check.jpg|25px]] ENHANCED: Measure Setup - Laser Probe Grid=== | ||
Line 100: | Line 101: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | |||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | [[image:vtube-laser_1_65_radiusstripescansuselaser.jpg|300px]] | ||
<br><br> | <br><br> | ||
− | |||
===[[image:Check.jpg|25px]] ENHANCED: Measure Setup - Scan Rate Grid=== | ===[[image:Check.jpg|25px]] ENHANCED: Measure Setup - Scan Rate Grid=== | ||
Line 115: | Line 115: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | |||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | [[image:vtube-laser_1_65_radiusstripescansscansrate.jpg|300px]] | ||
<br><br> | <br><br> | ||
− | |||
− | |||
===[[image:Check.jpg|25px]] Other Changes=== | ===[[image:Check.jpg|25px]] Other Changes=== | ||
Line 128: | Line 126: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | * | + | * A bug was found and removed from the MOVE command.<br><br> |
− | * The System Options menu allows you to browse directly into support folders from inside VTube-LASER. | + | * The System Options menu allows you to browse directly into support folders from inside VTube-LASER.<br><br> |
− | * VTube-LASER now uses the "All Users" or "ProgramData" folders to store configuration data for all users of the FARO computer. | + | * VTube-LASER now uses the "All Users" or "ProgramData" folders to store configuration data for all users of the FARO computer. This solves problems for companies that require that each user login to Windows with their own permissions setup.<br><br> |
− | * The Winton Machinery bender protocol was enhanced so that it automatically loads a template if no data is present in memory. | + | * The Winton Machinery bender protocol was enhanced so that it automatically loads a template if no data is present in memory when an operator is ready to send data to the bender.<br><br> |
</td> | </td> |
Latest revision as of 17:24, 19 May 2011
Revision 1.65Back to VTube-LASER |
NEW: Radius Correction for Push-Bending
The radius correction menu allows VTube-LASER to correct push-bends on Unison Limited benders. |
NEW: Bender Setup Changes
The Bender Setup window has a new easier-to-view color scheme.
The bend setup grid has a new column for inverting rotations that are sent out to the bender. This allows for sending the rotation the opposite direction - then remembering the inversion for next time the project is run. |
ENHANCED: New Torus-fit Engine for Radius Stripe Scanning
The new radius stripe scanning method is more accurate as of this version of VTube due to a new torus-fit engine included in VTube.
|
NEW: Bender Data + Corrections Data Chart in Reports
A new bender chart was added to the report template to include the bender data + corrections chart |
ENHANCED: Report Preview Menu
The Report Preview menu now allows you to change the printer and the paper orientation before printing. |
ENHANCED: Measure Setup - Laser Probe Grid
The Laser probe grid now has a separate checkbox for automatically enabling either laser or tactile measuring for radius stripe scans. |
ENHANCED: Measure Setup - Scan Rate Grid
The Scan Rate grid now has a separate controls for radius stripe scans. |
Other Changes
|
Issues with this version fixed in newer versions
|
Other Pages
- Back to VTube-LASER
VTube-LASER Training Video - How to perform effective end scans. |