Difference between revisions of "VTube-LASER v1.69"

From ATTWiki
Jump to: navigation, search
(25px REVISED: Overbend Calculator)
(25px ENHANCED: Report Values)
Line 31: Line 31:
  
 
===[[image:Check.jpg|25px]] ENHANCED: Report Values===
 
===[[image:Check.jpg|25px]] ENHANCED: Report Values===
[[image:vtube-laser_report_values_169.jpg|500px]]
+
[[image:vtube-laser_report_values_169.jpg|300px]]
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>

Revision as of 07:23, 3 September 2011

Vtube-laser logo.jpg

Revision 1.69

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser 1 69.jpg

Contents


Check.jpg ENHANCED: Measure Setup

Vtube-laser measure setup 1 69.jpg

Measure Setup allows operators to control more FARO server menus, and shows all the current FARO arm and probe data in a grid below the setup buttons.

Check.jpg ENHANCED: Report Values

Vtube-laser report values 169.jpg

Many report value fields were added to reports that show the arm and probe calibration and accuracy values. All of these values can be added to any report.

Check.jpg NEW: More Option in the Bender Setup

Vtube-laser bendersetup saveSV.jpg

Bender Setup can now save Supravision files from the bender setup data to the network. The menu can send either bender data with corrections or bender data without corrections. For uni-directional benders, you can merge Adjustments back into the bender data after sending data to the bender.

Check.jpg NEW: Added Tab Menus in the MASTER XYZ Menu

New tab menus with new options are now placed in separate tab menus in the Master XYZ menu.

Vtube-laser master xyz tabmenus setpoints.jpg
Vtube-laser master xyz tabmenus.jpg
Vtube-laser master xyz tabmenus splitbend.jpg




Check.jpg Other Changes

  • The radius values now correctly copy back to XYZ radius values when performing a reverse calc.
  • It is now possible to edit the blue-column bend ANGLE and ANGLE ADJUSMENT data in the Bender Setup menu.
  • A new LRA Master to Measured report is added.
  • Rotation corrections are always shift to the shortest side of the clock. For example +359 degree is reset to -1.0.
  • Now the tangent point/midpoint inspection grid is automatically set with the default tolerance when the grid grows.



Check.jpg Issues with this version fixed in newer versions

  • No known issues



Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg