Difference between revisions of "VTube-LASER v1.69"

From ATTWiki
Jump to: navigation, search
 
(25px ENHANCED: FARO Arm Measure Setup)
 
(26 intermediate revisions by one user not shown)
Line 8: Line 8:
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_screen_1_69.jpg|300px]]
+
[[image:vtube-laser_1_69.jpg|300px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 15: Line 15:
 
__TOC__
 
__TOC__
  
===[[image:Check.jpg|25px]] NEW: Excel Report Builder===
+
===[[image:Check.jpg|25px]] ENHANCED: FARO Arm Measure Setup===
[[image:vtube-laser_report_excel_button.jpg|300px]]
+
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
VTube-LASER can now build a Excel report quicklyThis is useful for taking your reports even further for Gage R&R an custom reports.
+
Measure Setup allows operators to control three more FARO windowsIt also shows all the current FARO arm and probe data in a grid below the setup buttons.
 
<br><br>
 
<br><br>
 +
[[image:vtube-laser_measure_setup_1_69.jpg|300px]]
 +
<br><br>
 +
Important changes given to us be users has been incorporated.  For example, during calibration, Measure Setup has been changed to automatically re-display the Probe Menu after a calibration has been completed.  (This is the standard approach that operators expect during calibration.)
 +
<br><br>
 +
All forms of calibration choices in the Probe Menu are now enabled in this version.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 29: Line 33:
 
</tr>  
 
</tr>  
 
</table>
 
</table>
[[image:vtube-laser_excel.jpg|500px]]
 
  
===[[image:Check.jpg|25px]] REVISED: Overbend Calculator===
+
===[[image:Check.jpg|25px]] ENHANCED: Arm Values Can Be Added to Reports===
[[image:vtube-laser_overbend.jpg|500px]]
+
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
The Overbend Calculator was redesigned and improved.
+
Many report value fields were added to the report logic.  These fields can show the arm and probe calibration and accuracy values.  Add these to any report or use them to create a custom report.
 +
<br><br>
 +
[[image:vtube-laser_report_values_169.jpg|400px]]
 +
<br><br>
 +
This allows the current state of the arm to be printed with the report - proving that the arm was calibrated during measurement.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 43: Line 49:
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] NEW: More Option in the Bender Setup===
+
===[[image:Check.jpg|25px]] NEW: Cut Plane Question Reminds Users To Consider Cut Plane===
[[image:vtube-laser_bendersetup_saveSV.jpg|250px]]
+
[[image:vtube-laser_cutplane_question.jpg|350px]]
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
Bender Setup can now save Supravision files from the bender setup data to the network.  The menu can send either bender data with corrections or bender data without corrections.  For uni-directional benders, you can merge Adjustments back into the bender data after sending data to the bender.
+
VTube now asks if you intend to establish a cut plane immediately after the arm is connected to VTube-LASER.
 
<br><br>
 
<br><br>
 
</td>
 
</td>
Line 56: Line 62:
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] NEW: Added Tab Menus in the MASTER XYZ Menu===
+
===[[image:Check.jpg|25px]] NEW: VTube-LASER Programmer License Mode===
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
New tab menus with new options are now placed in separate tab menus in the Master XYZ menu.
+
This new mode allows customers to purchase a license of VTube-LASER for programming VTube-LASER projects remotely where there is no need to connect to the FARO arm.
 +
<br><br>
 +
The license price for Programmer mode is significantly less expensive.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 66: Line 74:
 
</tr>  
 
</tr>  
 
</table>
 
</table>
[[image:vtube-laser_master_xyz_tabmenus_setpoints.jpg|300px]]<br>
+
[[image:vtube-laser_programmer_mode.jpg|300px]]
[[image:vtube-laser_master_xyz_tabmenus.jpg|300px]]<br>
+
[[image:vtube-laser_master_xyz_tabmenus_splitbend.jpg|300px]]<br>
+
 
<br><br>
 
<br><br>
 
 
 
 
  
 
===[[image:Check.jpg|25px]] Other Changes===
 
===[[image:Check.jpg|25px]] Other Changes===
Line 80: Line 82:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* The radius values now correctly copy back to XYZ radius values when performing a reverse calc.
+
* Transfluid fails to load the diameter and radius values if the values use more than two places of accuracy beyond the decimal.  So now VTube is careful to use only two places of accuracy beyond the decimal for those two values.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 88: Line 90:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* It is now possible to edit the blue-column bend ANGLE and ANGLE ADJUSMENT data in the Bender Setup menu.
+
* VTube can now correctly import a Transfluid file as MASTER data.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 96: Line 98:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* A new LRA Master to Measured report is added.
+
* The arm as mouse speed is now controlled in the FARO hardware configuration menu - not in VTube-LASER System Options as in previous versions.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
 
</td>
 
</td>
 
</tr>
 
</tr>
 
<tr valign=top>
 
<td width=300>
 
* Rotation corrections are always shift to the shortest side of the clock.  For example +359 degree is reset to -1.0.
 
</td>
 
<td width=300>
 
</td>
 
</tr>
 
 
<tr valign=top>
 
<td width=300>
 
* Now the tangent point/midpoint inspection grid is automatically set with the default tolerance when the grid grows.
 
</td>
 
<td width=300>
 
</td>
 
</tr>
 
 
 
 
  
  

Latest revision as of 12:53, 3 September 2011

Vtube-laser logo.jpg

Revision 1.69

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser 1 69.jpg

Contents


Check.jpg ENHANCED: FARO Arm Measure Setup

Measure Setup allows operators to control three more FARO windows. It also shows all the current FARO arm and probe data in a grid below the setup buttons.

Vtube-laser measure setup 1 69.jpg

Important changes given to us be users has been incorporated. For example, during calibration, Measure Setup has been changed to automatically re-display the Probe Menu after a calibration has been completed. (This is the standard approach that operators expect during calibration.)

All forms of calibration choices in the Probe Menu are now enabled in this version.

Check.jpg ENHANCED: Arm Values Can Be Added to Reports

Many report value fields were added to the report logic. These fields can show the arm and probe calibration and accuracy values. Add these to any report or use them to create a custom report.

Vtube-laser report values 169.jpg

This allows the current state of the arm to be printed with the report - proving that the arm was calibrated during measurement.

Check.jpg NEW: Cut Plane Question Reminds Users To Consider Cut Plane

Vtube-laser cutplane question.jpg

VTube now asks if you intend to establish a cut plane immediately after the arm is connected to VTube-LASER.

Check.jpg NEW: VTube-LASER Programmer License Mode

This new mode allows customers to purchase a license of VTube-LASER for programming VTube-LASER projects remotely where there is no need to connect to the FARO arm.

The license price for Programmer mode is significantly less expensive.

Vtube-laser programmer mode.jpg

Check.jpg Other Changes

  • Transfluid fails to load the diameter and radius values if the values use more than two places of accuracy beyond the decimal. So now VTube is careful to use only two places of accuracy beyond the decimal for those two values.
  • VTube can now correctly import a Transfluid file as MASTER data.
  • The arm as mouse speed is now controlled in the FARO hardware configuration menu - not in VTube-LASER System Options as in previous versions.



Check.jpg Issues with this version fixed in newer versions

  • No known issues



Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg