Difference between revisions of "VTube-LASER v1.69"
From ATTWiki
(21 intermediate revisions by one user not shown) | |||
Line 15: | Line 15: | ||
__TOC__ | __TOC__ | ||
− | ===[[image:Check.jpg|25px]] ENHANCED: Measure Setup=== | + | ===[[image:Check.jpg|25px]] ENHANCED: FARO Arm Measure Setup=== |
− | + | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | Measure Setup allows operators to control more FARO | + | Measure Setup allows operators to control three more FARO windows. It also shows all the current FARO arm and probe data in a grid below the setup buttons. |
+ | <br><br> | ||
+ | [[image:vtube-laser_measure_setup_1_69.jpg|300px]] | ||
+ | <br><br> | ||
+ | Important changes given to us be users has been incorporated. For example, during calibration, Measure Setup has been changed to automatically re-display the Probe Menu after a calibration has been completed. (This is the standard approach that operators expect during calibration.) | ||
<br><br> | <br><br> | ||
+ | All forms of calibration choices in the Probe Menu are now enabled in this version. | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Line 31: | Line 35: | ||
===[[image:Check.jpg|25px]] ENHANCED: Arm Values Can Be Added to Reports=== | ===[[image:Check.jpg|25px]] ENHANCED: Arm Values Can Be Added to Reports=== | ||
− | |||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | Many report value fields were added to | + | Many report value fields were added to the report logic. These fields can show the arm and probe calibration and accuracy values. Add these to any report or use them to create a custom report. |
+ | <br><br> | ||
+ | [[image:vtube-laser_report_values_169.jpg|400px]] | ||
<br><br> | <br><br> | ||
This allows the current state of the arm to be printed with the report - proving that the arm was calibrated during measurement. | This allows the current state of the arm to be printed with the report - proving that the arm was calibrated during measurement. | ||
Line 44: | Line 49: | ||
</table> | </table> | ||
− | ===[[image:Check.jpg|25px]] NEW: | + | ===[[image:Check.jpg|25px]] NEW: Cut Plane Question Reminds Users To Consider Cut Plane=== |
− | [[image:vtube- | + | [[image:vtube-laser_cutplane_question.jpg|350px]] |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | VTube now asks if you intend to establish a cut plane immediately after the arm is connected to VTube-LASER. | |
<br><br> | <br><br> | ||
</td> | </td> | ||
Line 57: | Line 62: | ||
</table> | </table> | ||
− | ===[[image:Check.jpg|25px]] NEW: | + | ===[[image:Check.jpg|25px]] NEW: VTube-LASER Programmer License Mode=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | This new mode allows customers to purchase a license of VTube-LASER for programming VTube-LASER projects remotely where there is no need to connect to the FARO arm. | |
+ | <br><br> | ||
+ | The license price for Programmer mode is significantly less expensive. | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Line 67: | Line 74: | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | [[image:vtube- | + | [[image:vtube-laser_programmer_mode.jpg|300px]] |
− | + | ||
− | + | ||
<br><br> | <br><br> | ||
− | |||
− | |||
− | |||
− | |||
===[[image:Check.jpg|25px]] Other Changes=== | ===[[image:Check.jpg|25px]] Other Changes=== | ||
Line 81: | Line 82: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | * | + | * Transfluid fails to load the diameter and radius values if the values use more than two places of accuracy beyond the decimal. So now VTube is careful to use only two places of accuracy beyond the decimal for those two values. |
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Line 89: | Line 90: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | * | + | * VTube can now correctly import a Transfluid file as MASTER data. |
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Line 97: | Line 98: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | * | + | * The arm as mouse speed is now controlled in the FARO hardware configuration menu - not in VTube-LASER System Options as in previous versions. |
</td> | </td> | ||
<td width=300> | <td width=300> | ||
</td> | </td> | ||
</tr> | </tr> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
Latest revision as of 12:53, 3 September 2011
Revision 1.69Back to VTube-LASER |
Contents |
ENHANCED: FARO Arm Measure Setup
ENHANCED: Arm Values Can Be Added to Reports
NEW: Cut Plane Question Reminds Users To Consider Cut Plane
VTube now asks if you intend to establish a cut plane immediately after the arm is connected to VTube-LASER.
|
NEW: VTube-LASER Programmer License Mode
This new mode allows customers to purchase a license of VTube-LASER for programming VTube-LASER projects remotely where there is no need to connect to the FARO arm.
|
Other Changes
|
|
|
|
|
Issues with this version fixed in newer versions
|