Difference between revisions of "VTube-LASER v1.71"

From ATTWiki
Jump to: navigation, search
 
(25px Other Changes)
 
(21 intermediate revisions by one user not shown)
Line 15: Line 15:
 
__TOC__
 
__TOC__
  
===[[image:Check.jpg|25px]] ENHANCED: Inspection Mathematics===
+
===[[image:Check.jpg|25px]] NEW: Transparent Envelope Models===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
The inspection mathematics is more accurate and is now better able to work with the short straights in split bends (where VTube combines the bends to make a single large bend).
+
VTube now draws transparent envelopes that help operators visualize in tolerance or out of tolerance parts relative to the envelope.
 
<br><br>
 
<br><br>
 +
[[image:vtube-laser_envelope.jpg|300px]]
 +
</td>
 +
<td width=300>
 +
[[image:vtube-laser_envelope_in_and_out.jpg|500px]]
 
</td>
 
</td>
 
</tr>  
 
</tr>  
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] REPAIR: Inspection Report Angles===
+
===[[image:Check.jpg|25px]] NEW: End Length and End Angle Tolerances===
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
The end angles in the inspection report are repaired and show accurate values.
+
The end lengths and end angles now have tolerances.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 36: Line 40:
 
</tr>  
 
</tr>  
 
</table>
 
</table>
 +
 +
[[image:vtube-laser_endtolerances.jpg|600px]]
 +
 +
 +
 +
===[[image:Check.jpg|25px]] NEW: End Length Report Chart and Tolerance Colors===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
* We've added a new end length chart on top of the inspection data (TP-MP-TP) chart.
 +
* The fonts are now colored based on tolerance pass-fail.
 +
</td>
 +
<td width=300>
 +
</td>
 +
</tr>
 +
</table>
 +
 +
[[image:vtube-laser_endlenchart.jpg|600px]]
 +
 +
===[[image:Check.jpg|25px]] ENHANCED: The DRO Is Now Always Active===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
Users asked us to make the DRO (Digital Readout) always active - even when laser points were not being scanned.  This helps us know that the arm is connected and returning values.
 +
</td>
 +
<td width=300>
 +
</td>
 +
</tr>
 +
</table>
 +
 +
[[image:vtube-laser_dro2.jpg]]
 +
 +
<br><br>
 +
 +
===[[image:Check.jpg|25px]] NEW: Envelope Tab Menu===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
The new Envelope tab menu controls the envelope model setup.
 +
</td>
 +
<td width=300>
 +
</td>
 +
</tr>
 +
</table>
 +
 +
[[image:vtube-laser_envelopetab.jpg|600px]]
  
 
===[[image:Check.jpg|25px]] Other Changes===
 
===[[image:Check.jpg|25px]] Other Changes===
Line 42: Line 92:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* An "Inspection Points" label is added above the tangent point/midpoint deviation grid.
+
* Changed the look of all grids to use Windows 7 style cells.
 +
* The master model in STEP mode will no longer continue to double itself.
 +
* New super-fast scanning sound that is directly tied to the incoming laser scans and tactile points.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>

Latest revision as of 15:15, 4 October 2011

Vtube-laser logo.jpg

Revision 1.71

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser 1 71b.jpg

Contents


Check.jpg NEW: Transparent Envelope Models

VTube now draws transparent envelopes that help operators visualize in tolerance or out of tolerance parts relative to the envelope.

Vtube-laser envelope.jpg

Vtube-laser envelope in and out.jpg

Check.jpg NEW: End Length and End Angle Tolerances

The end lengths and end angles now have tolerances.

Vtube-laser endtolerances.jpg


Check.jpg NEW: End Length Report Chart and Tolerance Colors

  • We've added a new end length chart on top of the inspection data (TP-MP-TP) chart.
  • The fonts are now colored based on tolerance pass-fail.

Vtube-laser endlenchart.jpg

Check.jpg ENHANCED: The DRO Is Now Always Active

Users asked us to make the DRO (Digital Readout) always active - even when laser points were not being scanned. This helps us know that the arm is connected and returning values.

Vtube-laser dro2.jpg



Check.jpg NEW: Envelope Tab Menu

The new Envelope tab menu controls the envelope model setup.

Vtube-laser envelopetab.jpg

Check.jpg Other Changes

  • Changed the look of all grids to use Windows 7 style cells.
  • The master model in STEP mode will no longer continue to double itself.
  • New super-fast scanning sound that is directly tied to the incoming laser scans and tactile points.

Check.jpg Issues with this version fixed in newer versions

  • No known issues



Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg