Difference between revisions of "VTube-LASER v1.75.1"

From ATTWiki
Jump to: navigation, search
 
(25px ENHANCED: Scanner Setup Enhancements)
Line 28: Line 28:
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] ENHANCED: Scanner Setup Enhancements===
+
===[[image:Check.jpg|25px]] FIX: Previous Move During Remeasure===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* This version addresses issues with handling the Scanner Setup in v1.74 project files.<br><br>
+
There were circumstances where VTube would backup too many steps during a remeasure.  This has been repaired.
* The current scanner setup is now displayed below the DRO.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:ScannerControlValues.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>  
 
</tr>  

Revision as of 12:10, 2 February 2012

Vtube-laser logo.jpg

Revision 1.75.1

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser 1 73.jpg


Check.jpg ENHANCEMENT: Added Page Numbers to Reports in Print Preview

VTube now shows the date, time, and page numbers at the bottom of print preview reports.

VTube-LASER Print Preview PageNumbers.jpg

Check.jpg FIX: Previous Move During Remeasure

There were circumstances where VTube would backup too many steps during a remeasure. This has been repaired.

Check.jpg NEW: Save MASTER BENDER Data from the MASTER XYZ Data Menu

VTube now includes a new FILE tab menu in the MASTER XYZ data menu. This file tab menu allows operators to save data to save the MASTER data to a BENDER file. The output can support any file-type that is currently supported in VTube.

This includes:

  • $$$ Supravision Files (Supravision legacy)
  • SV Supravision Files (DOCS)
  • S2B Supravision Files (For transferring using the Supravision Network protocol.)
  • CSM bender files
  • Winton bender files

SaveMasterBenderData.jpg


Check.jpg ENHANCEMENT: The Cylinder Fit Window is Redesigned

The Cylinder Fit window is now completely redesigned with new explanations to make the numbers more understandable. For example the new help text reads "SE2 = The centerline is accurate to these values with 95% certainty."

We've removed the X and Y Vector values because they were of no help in assuring accuracy of the centerline calculation in the display.

A new Radius Low/High and Deviation section is added to ensure that the points used to calculate the diameter are all within the same distances to the centerline calculated.

CylinderFitWindow v1 75.jpg


Check.jpg NEW: Cylinder Fit Radius Deviation Check

VTube now checks to be sure that all point clouds used in the diameter calculation all fall within a reasonable tolerance for distance from the calculated centerline.

CylindefFitRadiusDeviationCheck.jpg

Check.jpg NEW: "Pull Arm From Resting Position" Message

If the arm uses firmware version 702 or less, then it will display special messages when it is about to update the Scanner Control.

Follow these instructions if you change the Scanner Control setup from project to project.

The reason for this new step is that the Scanner Control will not update any integer values to or from VTube-LASER if the LASER is not able to be switched on during setup.

RemoveArmFromCradle1.jpg

Check.jpg NEW: Separate Cylinder Fit Tolerances for LONG and SHORT Cylinders

VTube now has a second set of tolerances for shorter straights. This allows for looser tolerances on shorter straights without producing an error message.

LongAndShortCylinderFitSetup.jpg



Check.jpg Other Changes

A new tolerance is added for surface point diameter check.


The current arm firmware is now read and used by VTube to determine how to handle the arm during Scanner Control changes.

ArmFirmware.jpg

For high-precision end scans, new end-scan techniques are recommended in the VTube-LASER manual.

EndScanAfterTarget.jpg

The VTube SVNET protocol now knows how to handle leftover communications files if they are present.

VTube can now save Supravision data to multiple file extension types: $$$, SV, or S2B

VTube-LASER now takes in scanned points faster than before.
VTube-LASER installation now allows for installing either MM or INCH default setups.
Default setups were fine-tuned in VTube-LASER so that VTube works faster.

Other Pages