Difference between revisions of "VTube-LASER v1.75.1"

From ATTWiki
Jump to: navigation, search
(25px NEW: Save MASTER BENDER Data from the MASTER XYZ Data Menu)
(25px FIX: Previous Move During Remeasure)
 
(6 intermediate revisions by one user not shown)
Line 40: Line 40:
 
</table>
 
</table>
  
 
+
===[[image:Check.jpg|25px]] ENHANCED: Removed the Default Radius Setup Message===
 
+
===[[image:Check.jpg|25px]] ENHANCEMENT: The Cylinder Fit Window is Redesigned===
+
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
The Cylinder Fit window is now completely redesigned with new explanations to make the numbers more understandable.  For example the new help text reads "SE2 = The centerline is accurate to these values with 95% certainty."<br><br>
+
The message that says that VTube will automatically set the default radius to 1.5 times the diameter no longer displays as it serves no useful purpose.</td>
We've removed the X and Y Vector values because they were of no help in assuring accuracy of the centerline calculation in the display.
+
<br><br>
+
A new Radius Low/High and Deviation section is added to ensure that the points used to calculate the diameter are all within the same distances to the centerline calculated.
+
</td>
+
 
<td width=300>
 
<td width=300>
[[image:CylinderFitWindow_v1_75.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>  
 
</tr>  
</table>
 
 
 
===[[image:Check.jpg|25px]] NEW: Cylinder Fit Radius Deviation Check===
 
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
VTube now checks to be sure that all point clouds used in the diameter calculation all fall within a reasonable tolerance for distance from the calculated centerline.
 
<br><br>
 
</td>
 
<td width=300>
 
[[image:CylindefFitRadiusDeviationCheck.jpg|300px]]
 
</td>
 
</tr>
 
</table>
 
 
===[[image:Check.jpg|25px]] NEW: "Pull Arm From Resting Position" Message===
 
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
If the arm uses firmware version 702 or less, then it will display special messages when it is about to update the Scanner Control.<br><br>
 
 
Follow these instructions if you change the Scanner Control setup from project to project.<br><br>
 
 
The reason for this new step is that the Scanner Control will not update any integer values to or from VTube-LASER if the LASER is not able to be switched on during setup.
 
</td>
 
<td width=300>
 
[[image:RemoveArmFromCradle1.jpg|300px]]
 
</td>
 
</tr>
 
</table>
 
 
===[[image:Check.jpg|25px]] NEW: Separate Cylinder Fit Tolerances for LONG and SHORT Cylinders===
 
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
VTube now has a second set of tolerances for shorter straights.  This allows for looser tolerances on shorter straights without producing an error message.
 
<br><br>
 
</td>
 
<td width=300>
 
[[image:LongAndShortCylinderFitSetup.jpg|300px]]
 
</td>
 
</tr>
 
</table>
 
 
 
 
 
===[[image:Check.jpg|25px]] Other Changes===
 
<table cellpadding=10>
 
 
<tr valign=top>
 
<td width=300>
 
A new tolerance is added for surface point diameter check.
 
</td>
 
<td width=300>
 
</td>
 
</tr>
 
</table>
 
 
 
<table cellpadding=10>
 
 
<tr valign=top>
 
<td width=300>
 
The current arm firmware is now read and used by VTube to determine how to handle the arm during Scanner Control changes.
 
</td>
 
<td width=300>
 
[[image:ArmFirmware.jpg|300px]]
 
</td>
 
</tr>
 
</table>
 
 
<table cellpadding=10>
 
 
<tr valign=top>
 
<td width=300>
 
For high-precision end scans, new end-scan techniques are recommended in the VTube-LASER manual.<br><br>
 
* See [[End-Scan Using the Scissor Motion]]
 
* See [[End-Scan Using the End Wall]]
 
* See [[End-Scan Using End Targets]]
 
 
</td>
 
<td width=300>
 
[[image:EndScanAfterTarget.jpg|300px]]
 
</td>
 
</tr>
 
</table>
 
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
The VTube SVNET protocol now knows how to handle leftover communications files if they are present.
 
</td>
 
<td width=300>
 
</td>
 
</tr>
 
</table>
 
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
VTube can now save Supravision data to multiple file extension types: $$$, SV, or S2B
 
</td>
 
<td width=300>
 
</td>
 
</tr>
 
</table>
 
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
VTube-LASER now takes in scanned points faster than before.</td>
 
<td width=300>
 
</td>
 
</tr>
 
</table>
 
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
VTube-LASER installation now allows for installing either MM or INCH default setups.</td>
 
<td width=300>
 
</td>
 
</tr>
 
</table>
 
 
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
Default setups were fine-tuned in VTube-LASER so that VTube works faster.</td>
 
<td width=300>
 
</td>
 
</tr>
 
 
</table>
 
</table>
  
 
=Other Pages=
 
=Other Pages=
 
*Back to [[VTube-LASER]]
 
*Back to [[VTube-LASER]]

Latest revision as of 18:08, 3 February 2012

Vtube-laser logo.jpg

Revision 1.75.1

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser 1 73.jpg


Check.jpg ENHANCEMENT: Added Page Numbers to Reports in Print Preview

VTube now shows the date, time, and page numbers at the bottom of print preview reports.

VTube-LASER Print Preview PageNumbers.jpg

Check.jpg FIX: Previous Move During Remeasure

There were circumstances where VTube would backup too many steps during a remeasure. This has been repaired.

Check.jpg ENHANCED: Removed the Default Radius Setup Message

The message that says that VTube will automatically set the default radius to 1.5 times the diameter no longer displays as it serves no useful purpose.