Difference between revisions of "Delay After Cycle Start"
From ATTWiki
(One intermediate revision by one user not shown) | |||
Line 1: | Line 1: | ||
+ | |||
+ | ===What is It?=== | ||
Delay After Cycle Start is a property in the [[main.axislist]] file in CNC Bender software. | Delay After Cycle Start is a property in the [[main.axislist]] file in CNC Bender software. |
Latest revision as of 14:50, 17 July 2006
What is It?
Delay After Cycle Start is a property in the main.axislist file in CNC Bender software.
Using the Value
Each of the sections in the main.axislist is set apart with an axis section label like this:
[Axis 1]
The value for each axis section can be set in milliseconds like this:
Delay After Cycle Start = 250
The axis with the highest value controls when all axes are enabled. For example, axis 3 may be set to 3000 (3 seconds), and the rest set to 250 (1/4 second). In this case, all axes will start after 3 seconds of delay.
--Mcone 10:45, 17 July 2006 (EDT)