* Set System Options, Measure 2 Tab, "Maximum Number of LLP Points in String" to 3
+
* Set Part Setup - Set the A-End Diameter to the diameter where the measurement will be taken.
* Set Measure Setup - LASER Tab: The LASER defaults to ON for CYLINDERS and END-SCANS.
+
* Set Measure Setup - LASER Tab: The LASER defaults to OFF for at least END-SCANS.
* Set Measure Setup - LASER Tab: Cylinder stripes = 3 to 5
+
* Set Measure Setup - TACTILE Tab: Uncheck the Continuous Scan on Tactile End-Scans.
* Set Measure Setup - LASER Tab: End-scan stripes = 5
+
* Set Measure Setup - TACTILE Tab: Set the Offset for each end to "TOWARD BEND" if the measurement is on the end wall. (Set the Offset "AWAY" if the tube end is moving into a surface.)
* Set Measure Setup - LASER Tab: Split bend stripes = 5
+
* Set Measure Setup = Scan Rates Tab: Set all rates to TIMER for all scan types.
+
* Set Measure Setup = Scan Rates Tab: Set the Scan Rates TIMER is set to 0 for all TIMERS.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>

Revision as of 00:06, 22 June 2012

Vtube-laser logo.jpg How to perform end-scans with a ball probe.

Vtube-laser 1 73.jpg


Why the End-Scan technique is important

This end-scan method is useful for situations where the only option is a ball probe - or where the Laser cannot reach effectively - but a ball probe can.

Using a ball probe is very precise as long as the tube is properly held with a work holder.

The main drawback is that the tube must be securely mounted without deforming the shape. It must also be touched - thereby potentially moving the tube - which will invalidate most measurements.)


Measure Setup

  • Set Part Setup - Set the A-End Diameter to the diameter where the measurement will be taken.
  • Set Measure Setup - LASER Tab: The LASER defaults to OFF for at least END-SCANS.
  • Set Measure Setup - TACTILE Tab: Uncheck the Continuous Scan on Tactile End-Scans.
  • Set Measure Setup - TACTILE Tab: Set the Offset for each end to "TOWARD BEND" if the measurement is on the end wall. (Set the Offset "AWAY" if the tube end is moving into a surface.)

How To Use This End-Scan Technique

  • Align the scanner with a slight scissor angle across the end as is shown in the image on the right

  • Attempt to hold the laser motionless when collecting the stripes across the end to increase repeatability.

  • Consistently place the line across the same area of the tube end from measure to measure.

  • Press the green button until VTube-LASER is finished scanning all the end stripes.

EndWithScissorCloseup.jpg

EndWithScissor.jpg