Difference between revisions of "CNC Bender v12-20120919"

From ATTWiki
Jump to: navigation, search
(v12-20120915)
 
(10 intermediate revisions by one user not shown)
Line 2: Line 2:
 
<tr>
 
<tr>
 
<td width=200>
 
<td width=200>
==v12-20120915==
+
==v12-20120919==
 
*Back to [[CNC Bender Software Updates]]
 
*Back to [[CNC Bender Software Updates]]
 
*To download the update see the [http://www.advancedtubular.com/customers/cncbender/page-downloads/version-12-20120830.html support page].
 
*To download the update see the [http://www.advancedtubular.com/customers/cncbender/page-downloads/version-12-20120830.html support page].
Line 16: Line 16:
  
  
===[[image:Check.jpg|25px]] ENHANCED: Vector Laservision Communications ===
+
===[[image:Check.jpg|25px]] REPAIR: Windows Version Vector Laservision Communications Compatibility Issue Repaired ===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
There was an issue in the transfer of data from the bender to the new Windows version of the Vector software in multi-radius mode.  This has been resolved.
+
There was a command instruction (transmission code) problem in the transfer of data from the bender to the new Windows version of the Vector software in multi-radius mode.  During a GET, the Vector would only get half of the data, the stop expecting more because of this problem.  (The old DOS version of Vector did not have this problem.)<br><br>
 +
 
 +
This version fixes that issue that the transmission works with the new Windows version of Vector Laservision.
 
</td>
 
</td>
  
Line 29: Line 31:
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] ENHANCED: Move Jog Window Up and Right ===
+
===[[image:Check.jpg|25px]] ENHANCED: Move Jog Queue Window Up and Right ===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
The jog queue window is moved up and to the right to stay away from other buttons on the screen.
+
The jog queue window is moved up and to the right to stay away from other buttons on the screen during jogging.
 
</td>
 
</td>
  
Line 41: Line 43:
 
</tr>
 
</tr>
 
</table>
 
</table>
 
  
 
=Other Pages=
 
=Other Pages=

Latest revision as of 02:50, 21 September 2012

v12-20120919

Cncv12procontrol withteachmode.jpg


Check.jpg REPAIR: Windows Version Vector Laservision Communications Compatibility Issue Repaired

There was a command instruction (transmission code) problem in the transfer of data from the bender to the new Windows version of the Vector software in multi-radius mode. During a GET, the Vector would only get half of the data, the stop expecting more because of this problem. (The old DOS version of Vector did not have this problem.)

This version fixes that issue that the transmission works with the new Windows version of Vector Laservision.

Check.jpg ENHANCED: Move Jog Queue Window Up and Right

The jog queue window is moved up and to the right to stay away from other buttons on the screen during jogging.

Other Pages