Difference between revisions of "CNC Bender v12-20120919"
From ATTWiki
(→v12-20120915) |
|||
(8 intermediate revisions by one user not shown) | |||
Line 2: | Line 2: | ||
<tr> | <tr> | ||
<td width=200> | <td width=200> | ||
− | ==v12- | + | ==v12-20120919== |
*Back to [[CNC Bender Software Updates]] | *Back to [[CNC Bender Software Updates]] | ||
*To download the update see the [http://www.advancedtubular.com/customers/cncbender/page-downloads/version-12-20120830.html support page]. | *To download the update see the [http://www.advancedtubular.com/customers/cncbender/page-downloads/version-12-20120830.html support page]. | ||
Line 16: | Line 16: | ||
− | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] REPAIR: Windows Version Vector Laservision Communications Compatibility Issue Repaired === |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | There was | + | There was a command instruction (transmission code) problem in the transfer of data from the bender to the new Windows version of the Vector software in multi-radius mode. During a GET, the Vector would only get half of the data, the stop expecting more because of this problem. (The old DOS version of Vector did not have this problem.)<br><br> |
+ | |||
+ | This version fixes that issue that the transmission works with the new Windows version of Vector Laservision. | ||
</td> | </td> | ||
Line 34: | Line 36: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | The jog queue window is moved up and to the right to stay away from other buttons on the screen. | + | The jog queue window is moved up and to the right to stay away from other buttons on the screen during jogging. |
</td> | </td> | ||
Latest revision as of 02:50, 21 September 2012
v12-20120919
|
REPAIR: Windows Version Vector Laservision Communications Compatibility Issue Repaired
There was a command instruction (transmission code) problem in the transfer of data from the bender to the new Windows version of the Vector software in multi-radius mode. During a GET, the Vector would only get half of the data, the stop expecting more because of this problem. (The old DOS version of Vector did not have this problem.) This version fixes that issue that the transmission works with the new Windows version of Vector Laservision. |
ENHANCED: Move Jog Queue Window Up and Right
The jog queue window is moved up and to the right to stay away from other buttons on the screen during jogging. |
Other Pages
- Back to CNC Bender
- Back to CNC Bender Software Updates
- See CNC Bender General Information
- See Teach Mode
- See Custom Commands