Difference between revisions of "VTube-LASER v1.81"

From ATTWiki
Jump to: navigation, search
(New Inspection Grid Row Count Control)
(New Winton ECNC 4 Bender Setup and Correction)
 
(28 intermediate revisions by one user not shown)
Line 10: Line 10:
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:Vtube-laser_1.78.jpg|300px]]
+
[[image:Vtube-laser_1.81.jpg|300px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 18: Line 18:
  
 
* See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version.
 
* See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version.
<br><br>
+
<br>
 +
 
 +
===New Winton ECNC 4 Bender Setup and Correction===
 +
<table>
 +
<tr>
 +
<td width=300 valign=top>
 +
[[image:winton_logo.jpg|300px]]<br>
 +
[[image:winton_bender.jpg|300px]]<br>
 +
*This version can read and write ECNC version 4 offline program files.
 +
*Every value that can be setup in ECNC can also be setup in VTube-LASER.
 +
</td>
 +
<td valign=top>
 +
[[image:winton_ecnc_4_screen.jpg|400px]]<br>
 +
</td>
 +
</tr>
 +
</table>
 +
 
 +
<table>
 +
<tr>
 +
<td width=300 valign=top>
 +
[[image:vtubelaser_winton_ecnc_4_wholescreen2.jpg|400px]]
 +
<br>
 +
</td>
 +
<td valign="top">
 +
[[image:vtubelaser_winton_ecnc_4_screen.jpg|400px]]
 +
</td>
 +
</tr>
 +
</table>
  
 
===New Separate Report Template Setup for STEP and LASER===
 
===New Separate Report Template Setup for STEP and LASER===
Line 24: Line 51:
 
*Some report templates are only appropriate in LASER because LASER handles inspections.
 
*Some report templates are only appropriate in LASER because LASER handles inspections.
 
*Now the setup of each is stored separately.
 
*Now the setup of each is stored separately.
 
 
<br>
 
<br>
 
  
 
===New Supravision Project Wall Thickness Import/Output ===
 
===New Supravision Project Wall Thickness Import/Output ===
Line 44: Line 69:
  
 
===New Inspection Grid Row Count Control===
 
===New Inspection Grid Row Count Control===
*VTube now controls the grid row count with the MASTER data row count.  If the MASTER data as rows of points alone, then the inspection grid now also has rows to allow data entry for tolerances.
+
*VTube now controls the INSPECTION grid row count with the MASTER data row count rather than the MEASURED data row count.
 
*This allows the grid to be populated even if the Measured data is cleared.
 
*This allows the grid to be populated even if the Measured data is cleared.
  

Latest revision as of 01:55, 19 January 2013

Vtube-laser logo.jpg

Revision 1.81

Vtube-laser 1.81.jpg



New Winton ECNC 4 Bender Setup and Correction

Winton logo.jpg
Winton bender.jpg

  • This version can read and write ECNC version 4 offline program files.
  • Every value that can be setup in ECNC can also be setup in VTube-LASER.

Winton ecnc 4 screen.jpg

Vtubelaser winton ecnc 4 wholescreen2.jpg

Vtubelaser winton ecnc 4 screen.jpg

New Separate Report Template Setup for STEP and LASER

  • Previous versions had identical setups in both modes.
  • Some report templates are only appropriate in LASER because LASER handles inspections.
  • Now the setup of each is stored separately.


New Supravision Project Wall Thickness Import/Output

  • Previous versions did not save the wall thickness
  • This version imports and exports the wall thickness value.


New Supravision Project Qualification Tolerance Envelopes Import/Export

  • This version now imports and exports these values:
    • Default Qualification Envelope Tolerance
    • A End Length Qualification Tolerance
    • B End Length Qualification Tolerance
    • A End Angle Qualification Tolerance
    • B End Angle Qualification Tolerance


New Inspection Grid Row Count Control

  • VTube now controls the INSPECTION grid row count with the MASTER data row count rather than the MEASURED data row count.
  • This allows the grid to be populated even if the Measured data is cleared.